Laserfiche WebLink
Total Tension from <br />Risers to Each Affected <br />Strap <br />Tstp_r_toti Tstp_r <br />T i <br /> the location of each riser <br />from the left end of the tank <br />Each row represents <br />the tension on each <br />strap from all risers <br />The first and last rows <br />are the fictitious <br />straps at tip of <br />endcaps. <br />Tstp_r_tot <br />0 <br />1108 <br />2367 <br />1373 <br />0 <br />lbf La' <br />0.00 <br />82.75 <br />152.25 <br />218.25 <br />284.50 <br />in <br />Combine the <br />Tension from <br />Risers to <br />Fictitious Straps <br />to Nearest Anchor <br />Strap <br />Tstp_r_tot'submatrix Tstp_r_tot 1last La' 100  <br />Tstp_r_tot'0 Tstp_r_tot'0 Tstp_r_tot 0 <br />Tstp_r_tot'last Tstp_r_tot' Tstp_r_tot'last Tstp_r_tot' Tstp_r_tot last Tstp_r_tot  <br />Each row <br />represents the riser <br />tension loads for <br />each strap. <br />The location of <br />each strap <br />from the left <br />end of the <br />tank. <br />Tstp_r_tot' <br />1108 <br />2367 <br />1373 <br />lbf La <br />83 <br />152 <br />218 <br />in <br />1 <br />cos A4an 1.012 the actual tension load on the hardware will be higher by this factor than <br />the straight up buoyancy load since the actual tension is at the pull angle <br />Tank Buoyancy, Rotten Robbie No 69, <br />Manteca CA, dwg 17366-001, 10ft DWT <br />Date Printed: 9/7/2023 Page 42 of 46