Laserfiche WebLink
SHEET NUMBER: <br />SHEET CONTENTS: <br />PROJECT NUMBER:PROJECT DATE: <br />CONSULTANTS: <br />REVISIONS: <br />18-046 12-24-2020 <br />DEVELOPER: <br />CONTRACTOR: <br />PROJECT: <br />PROFESSIONAL SEALS: <br />1014 S. Airport Road <br />Manteca, California <br /> 95336 <br />1 <br />2 <br />Robinson Oil Corporation <br />955 Martin Ave. <br />Santa Clara, CA 95050 <br />Sacramento, CA 95827 <br />PH:(916) 455-6500 FAX:(916) 455-8100 <br />3090 Fite Circle, #104 <br />K12 Architects, Inc <br />CONVENIENCE STORE & <br />FUELING CANOPY <br />MANTECA <br />3 <br />4 <br />PLAN CHECK JAN. 12, 2023 <br />OWNER CHANGE MARCH 17, 2023 <br />PLAN CHECK AUGUST 17, 2023 <br />PLAN CHECK MARCH 29, 2024 <br />PLAN CHECK hzmt MAY 10, 2024 <br />5 PLAN CHECK hzmt MAY 31, 2024 <br />6 PLAN CHECK hzmt AUGUST 7, 2024 <br /> February 03, 2025 <br />8 PLAN CHECK hzmt OCT. 26, 2024 <br />7 PLAN CHECK hzmt SEPT. 26, 2024 <br />10 PLAN CHECK hzmt JAN 29, 2025 <br />9 PLAN CHECK hzmt JAN 09, 2025 <br />14 91 UNLEADED FUEL TANK SECTION <br />1/2" = 1'-0"SCALE: <br />FS3.1 <br />TANK SECTIONS <br />3 <br />4 <br />23-8 1/2"18" min18" min <br />EARTH, TYP.5"1'-0"PEA GRAVEL <br />BED <br />DEFLECTOR PLATE <br />FOR DEADMEN AND <br />STRAPS SEE DETAILFABRIC LINER IF REQUIRED <br />DEFLECTOR PLATE <br />NOTE: <br />THE TANK AND THE TANK SUMPS HAVE CALCIUM <br />CHLORIDE IN THE INTERSTITIAL SPACE. <br />CONTRACTOR TO LABEL FILL PORTS WITH TYPE <br />OF FILL. <br />3/8"Ø WASHED PEA GRAVEL BACKFILL <br />ALL OPEN GRADED MATERIALS SHALL BE <br />FULLY ENCASED IN A GEOTEXTILE FILTER <br />FABRIC, SUCH AS MIRAFI 140N, TO PREVENT <br />MIGRATION OF FINE GRAINED SOILS INTO THE <br />POROUS MATERIAL. GRAVEL SHOULD BE <br />PLACED IN THIN (LESS THAN 8 INCH) LIFTS AND <br />DENSIFIED WITH MINIMUM OF (3) PASSES USING <br />A VIBRATORY COMPACTOR PRIOR TO <br />PLACEMENT OF THE NEXT LIFT. <br />8" CONCRETE SLAB SHALL <br />EXTEND A MIN OF 2'-0" BEYOND <br />THE ENDS AND SIDES OF <br />TANKS, SEE SITE PLAN <br />81 <br />4" RISER <br />SCHEDULE 40 <br />VEEDER-ROOT <br />INTERSTITIAL SENSOR <br />MAG PLUS <br />LIQUID LEVEL <br />PROBE <br />7417 <br />DROP TUBE WITH <br />OVERFILL VALVE <br />SET AT 95% <br />8 <br />FS4.1 <br />12 <br />FS4.1 <br />6 <br />FS4.1 <br />- <br />FS6.0 <br />3 <br />12,000 <br />91 PREMIUM <br />3x2 SMITH FIBERGLASS <br />BONDED ENTRY FITTING <br />MAG PROBE RISER CAP <br />SCHEDULE 40 NIPPLE, <br />LENGTH AS REQUIRED, <br />TYPICAL <br />SCHEDULE 40 90° <br />ELBOW - TYPICAL <br />SCHEDULE 40 PIPE NIPPLE, <br />LENGTH AS REQUIRED TO <br />OFFSET VENT LINE AND <br />CLEAR MAG PROBE <br />HOUSING ASSEMBLY <br />LINE OF SUBMERSIBLE <br />PUMP ABOVE <br />EXTRACTOR FITTING AS <br />SCHEDULED <br />8 - PLAN VIEW <br />8A - ELEVATION <br />DOUBLETRACⓇBY OMEGAFLEX NPT <br />ADAPTER <br />SMITH FIBERGLASS BONDED <br />ENTRY FITTING, TYPICAL <br />VENT RISER PIPING, 3" OVER <br />2" RED THREAD IIA <br />FIBERGLASS PIPE, VACUUM <br />MONITORED <br />4"Ø SCHEDULE 40 <br />PUMP RISER <br />CONTAINMENT SUMP <br />AS SCHEDULED <br />SCHEDULE 40 NIPPLE, <br />LENGTH AS REQUIRED, <br />TYPICAL <br />EXTRACTOR FITTING AS SCHEDULED <br />SCHEDULE 40 90° <br />ELBOW - TYPICAL <br />U.S.T. MANWAY COVER <br />UNDERGROUND STORAGE <br />TANK AS SCHEDULED, SEE <br />TANK INSTALLATION PLAN <br />CONTAINMENT SUMP AS <br />SCHEDULED <br />CONNECT TO VACUUM <br />MONITORING SYSTEM, TYPICAL <br />VENT PIPING, 3" OVER 2" RED <br />THREAD IIA FIBERGLASS PIPE, <br />VACUUM MONITORED <br />VAPOR PIPING, 4" OVER 3" RED <br />THREAD IIA FIBERGLASS PIPE, <br />VACUUM MONITORED <br />SCHEDULE 40 90° ELBOW <br />- TYPICAL <br />OFFSET PIPE ASSEMBLY AS <br />REQUIRED TO CLEAR MAG <br />PROBE HOUSING ASSEMBLY <br />MAG PROBE CAP BEYOND <br />SCHEDULE 40 NIPPLE, <br />LENGTH AS REQUIRED, <br />TYPICAL <br />SCHEDULE 40 90° ELBOW - <br />OFFSET FITTING AS REQUIRED <br />TO CLEAR VAPOR PIPE <br />ASSEMBLY <br />LINE OF VENT PIPING ABOVE <br />VAPOR PIPING, 4" OVER 3" <br />RED THREAD IIA FIBERGLASS <br />PIPE, VACUUM MONITORED <br />TANK MANWAY COVER <br />8A <br />FS3.1 <br />4x3 SMITH FIBERGLASS <br />BONDED ENTRY FITTING <br />DOUBLETRACⓇBY OMEGAFLEX <br />FLEXIBLE HOSE AS SCHEDULED <br />DOUBLETRACⓇBY OMEGAFLEX <br />CONNECTOR CLAMP <br />DOUBLETRACⓇBY OMEGAFLEX FRP <br />GLUE CONNECTOR <br />8 EXTRACTOR VENT/VAPOR PIPE ASSEMBLY <br />1" = 1'-0"SCALE: <br />5 <br />5 <br />DOUBLETRACⓇBY <br />OMEGAFLEX 90° ELBOW FRP <br />GLUE CONNECTOR AS <br />SCHEDULED <br />1-1/2" DOUBLE POPPET MALE <br />PRODUCT SHEAR VALVE <br />3" OVER 2" RED THREAD <br />IIA FIBERGLASS PIPING <br />SENSOR MOUNTING BRACKET <br />PER MANUFACTURERS <br />INSTALLATION KIT <br />CONCRETE DRIVE SLAB, <br />SEE SITE PLAN <br />WESTERN FIBERGLASS DOUBLE <br />WALL, UNDER DISPENSER <br />CONTAINMENT SUMP <br />DOUBLETRACⓇBY OMEGAFLEX FLEX <br />CONNECTOR AS SCHEDULED <br />DISPENSER FRAME <br />BASE <br />18 / FS3.118 / FS3.1FUEL DISPENSER <br />AS SCHEDULED <br />DISPENSER ANCHOR <br />BOLT <br />DISPENSER SUMP FRAME <br />3x2 SMITH FIBERGLASS <br />BONDED ENTRY FITTING <br />2-1 SENSOR IN BACKGROUNG <br />DOUBLE POPPET VAPOR <br />SHEAR VALVE <br />3" OVER 2" RED THREAD <br />IIA FIBERGLASS PIPING <br />DISPENSER ANCHOR BOLT <br />CONCRETE DRIVE SLAB, <br />SEE PLAN <br />VAPOR FLOW SENSOR, <br />TYPICAL AT EACH DISPENSER <br />VAPOR PRESSURE SENSOR, <br />TYPICAL AT EACH DISPENSER <br />SMITH FIBERGLASS BONDED <br />ENTRY FITTING <br />DOUBLETRACⓇBY <br />OMEGAFLEX 90° ELBOW FRP <br />GLUE CONNECTOR AS <br />SCHEDULED <br />THREE WAY BALL VALVE <br />WESTERN FIBERGLASS DOUBLE <br />WALL, UNDER DISPENSER <br />CONTAINMENT SUMP <br />DISPENSER SUMP FRAME <br />18 / FS3.118 / FS3.1DOUBLETRACⓇBY OMEGAFLEX FLEX <br />CONNECTOR AS SCHEDULED <br />VEEDER-ROOT <br />NON-DISCRIMINATING PIPING <br />SUMP SENSOR <br />CONDUITS TO BE <br />ROUTED THROUGH <br />SLOT IN SUMP <br />FRAME <br />ELECTRICAL <br />SEAL OFF <br />VAPOR SHEAR VALVE <br />NON-DISCRIMINATING <br />PIPING SUMP SENSOR <br />DISPENSER SUMP FRAME <br />NEW CONCRETE DRIVE <br />SLAB, SEE FUELING <br />SITE PLAN <br />WESTERN FIBERGLASS <br />DOUBLE WALL, UNDER <br />DISPENSER <br />CONTAINMENT SUMP <br />DOUBLETRACⓇBY <br />OMEGAFLEX FLEX <br />CONNECTOR AS <br />SCHEDULED, TYPICAL <br />FUEL DISPENSER <br />AS SCHEDULED <br />PRODUCT SHEAR VALVE, <br />TYPICALJUNCTION BOX <br />19 / FS3.119 / FS3.120 / FS3.120 / FS3.1HYDROSTATIC <br />RESERVOIR WITH MINI <br />HYDROSTATIC <br />SENSEOR <br />2 TO 1 SENSOR <br />INPUT BOX <br />RIGID UNDERGROUND <br />CONDUIT, SEE <br />ELECTRICAL DRAWINGS <br />FUEL DISPENSER SUMP - PRODUCT LINE <br />1" = 1'-0"SCALE: <br />20 <br />FUEL DISPENSER SUMP - VAPOR LINE <br />1" = 1'-0"SCALE: <br />19 <br />SECTION @ FUEL DISPENSER SUMP <br />1" = 1'-0"SCALE: <br />18 <br />NOTES: <br />A.ALL VAPOR RECOVERY CROSS OVER PIPING TO BE MADE WITH TEE(OR 90° ELL), SHORT NIPPLE <br />AND 45° ELL. <br />B.SLOPE PRODUCT PIPING TOWARD UNDERGROUND FUEL STORAGE TANKS OR DISPENSER SUMP <br />AT 1/8" PER FOOT MINIMUM. <br />C.VAPOR RECOVERY LINES TO SLOPE 1/8"/FT. TO REGULAR UNLEADED TANK. <br />D.PRODUCT LINES AND DISPENSER CONNECTIONS MAY NOT BE IN SAME ALIGNMENT. USE <br />FLEXIBLE CONNECTORS AND ROTATE TEES (OR ELBOWS) LEFT OR RIGHT OF VERTICAL AS <br />NECESSARY TO MAKE CONNECTIONS. <br />E.AT VERTICAL SEPARATION, PROVIDE MINIMUM OF 6 INCHES OF WELL-COMPACTED BEDDING <br />MATERIAL. <br />DOUBLE WALL FRP <br />PIPE, SEE FUEL <br />PIPING SITE PLAN <br />FOR SIZE AND <br />LAYOUT <br />1'-0"1'-0"6"1'-0"PROD <br />U <br />C <br />T <br /> <br />P <br />I <br />P <br />I <br />N <br />G <br />3"Ø O <br />V <br />E <br />R <br /> <br />2 <br />" <br />Ø <br /> <br />F <br />R <br />P <br /> SUMP WALL1 / 2 " MIN.BETWEENFITTINGS6"MIN.CLR.8" <br />M <br />I <br />N <br />. <br />CL <br />R <br />. <br />TY <br />P <br />. <br />FRP PIPE TERMINATION <br />FITTINGS, TYPICAL <br />PROD <br />U <br />C <br />T <br /> <br />P <br />I <br />P <br />I <br />N <br />G <br />3"Ø O <br />V <br />E <br />R <br /> <br />2 <br />" <br />Ø <br /> <br />F <br />R <br />P <br />PROD <br />U <br />C <br />T <br /> <br />P <br />I <br />P <br />I <br />N <br />G <br />3"Ø O <br />V <br />E <br />R <br /> <br />2 <br />" <br />Ø <br /> <br />F <br />R <br />P <br />VAPO <br />R <br /> <br />P <br />I <br />P <br />I <br />N <br />G <br />4"Ø O <br />V <br />E <br />R <br /> <br />3 <br />" <br />Ø <br /> <br />F <br />R <br />P <br />℄ <br />℄ <br />℄ <br />℄ <br />℄ <br />ADDITIONAL FRP PIPING <br />PER PIPING PLAN <br />TYPICAL PIPING CROSS OVER <br />3/4" = 1'-0"SCALE: <br />16 <br />3/4" RGS PVC <br />COATED CONDUIT <br />OVERFILL ALARM <br />ALARM ACKNOWLEDGE <br />SWITCH <br />1/2" LIQUID TIGHT FLEX, <br />TYPICAL <br />4x4 NEMA 3R JUNCTION <br />BOX <br />24"x14"x1/4" STEEL <br />MOUNTING PLATE, <br />ROUND CORNERS AND <br />EASE EDGES <br />WATERPROOF <br />RECEPTICAL <br />SEAL-OFF <br />EMERGENCE SHUT-OFF <br />SWITCH NEW <br />WATERPROOF <br />ENCLOSURE1'-0"1'-6"1'-6" <br />4"x4"x1/4" HSS POST <br />3"MIN.1'-6"Ø <br />TYP. <br />6"Ø SCHEDULE 40 <br />STEEL PIPE BOLLARD <br />WITH CONCRETE FILL, <br />TYPICAL <br />PLAN VIEW <br />WELDED PLATE CAP <br />NOTE: <br />PRIME AND PAINT ALL STEEL TO <br />MATCH SITE CONDITIONS <br />FINISH GRADE <br />+54" <br />MAX. <br />REMOTE E.S.O SWITCH <br />3/4" = 1'-0"SCALE: <br />12 <br />666 <br />6 <br />6 <br />6 <br />5 <br />8 <br />8 <br />10 <br />8 <br />81'-0"10'-338"OUTSIDE DIAMETER TANK RIBS6'-10"10'-0"TANK OUTSIDE DIAMETER18'-2"9 <br />9 <br />9 <br />10 <br />10 <br />PLAN ELEV. <br />10 <br />FS4.1 <br />7 <br />FS4.1 <br />10 <br />PLAN ELEV. <br />10 <br />9 <br />10 <br />109 <br />9 10 <br />9 <br />10