|
New Construction Fittings F Series
<br />Full-Body Chart - Dimensions
<br />Innovative Solutions for SecondaryContainment
<br />www.sbravo.com | 800.282.7286
<br />DS-8.03_12.22Page 2 of 2
<br />F Series Full-Body, Flat Sump Wall
<br />F Series Full-Body, Round Sump Wall
<br />Pipe type Part # Description
<br />3/4" galvanized conduit F-07S-0-F 3/4" galvanized conduit, full-body with duel injection ports, EPOXY REQ'D
<br />3/4" PVC coated conduit F-07RS-0-F 3/4" PVC coated condut, full-body with duel injection ports, EPOXY REQ'D
<br />3/4" galvanized conduit F-07S-0-DF 3/4" galvanized conduit, doublewall full-body, duel injection ports and tertiary boot seal, Flat wall
<br />FRP, EPOXY REQ'D
<br />3/4" PVC coated conduit F-07RS-0-DF 3/4" PVC coated conduit, doublewall full-body, duel injection ports and tertiary boot seal,
<br />Flat wall FRP, EPOXY REQ'D
<br />1" galvanized conduit F-10S-0-F 1" galvanized conduit, full-body with duel injection ports, EPOXY REQ'D
<br />1" PVC coated conduit F-10RS-0-F 1" PVC coated conduit, full-body with duel injection ports, EPOXY REQ'D
<br />1" galvanized conduit F-10S-0-DF 1" galvanized conduit, doublewall full-body, duel injection ports and tertiary boot seal, Flat
<br />wall FRP, EPOXY REQ'D
<br />1" PVC coated conduit F-10RS-0-DF 1" PVC coated conduit, doublewall full-body, duel injection ports and tertiary boot seal, Flat wall
<br />FRP, EPOXY REQ'D
<br />3/4 brass ground- ing rod F-07-GR 3/4" brass grounding rod, full-body with brass conductor and clamps, EPOXY REQ'D
<br />3 x 2" FRP F-32S-T-F 3x2" FRP, full-body taper by slip; dual test ports and single injection port, EPOXY REQ'D
<br />4 x 3" FRP F-43S-T-F
<br />4x3" FRP, full-body taper by slip; dual test ports and single injection port, EPOXY REQ'D
<br />6 x 4" FRP F-64S-T-F 6x4" FRP, full-body taper by slip; dual test ports and single injection port, EPOXY REQ'D
<br />3 x 2" FRP F-32A-T-F
<br />3x2" FRP, adjustable full-body taper by slip; dual test ports and single injection port, EPOXY
<br />REQ'D
<br />4 x 3" FRP F-43A-T-F 4x3" FRP, adjustable full-body taper by slip; dual test ports and single injection port, EPOXY
<br />REQ'D
<br />Pipe type Part # Description
<br />3/4" galvanized conduit F-07S-0-R 3/4" galvanized conduit, full-body with duel injection ports, EPOXY REQ'D
<br />3/4" PVC coated conduit F-07RS-0-R 3/4" PVC coated conduit, full-body with duel injection ports, EPOXY REQ'D
<br />3/4" galvanized conduit F-07S-0-DR 3/4" galvanized conduit, doublewall full-body, duel injection ports and tertiary boot seal, Round wall FRP, EPOXY REQ'D
<br />3/4" PVC coated conduit F-07RS-0-DR 3/4" PVC coated conduit, doublewall full-body, duel injection ports and tertiary boot seal, Round wall FRP, EPOXY
<br />REQ'D
<br />1" galvanized conduit F-10S-0-R 1" galvanized conduit, full-body with duel injection ports, EPOXY REQ'D
<br />1" PVC coated conduit F-10RS-0-R 1" PVC coated conduit, full-body with duel injection ports, EPOXY REQ'D
<br />1" galvanized conduit F-10S-0-DR 1" galvanized conduit, doublewall full-body, duel injection ports and tertiary boot seal, Round wall FRP, EPOXY REQ'D
<br />1" PVC coated conduit F-10RS-0-DR 1" PVC coated conduit, doublewall full-body, duel injection ports and tertiary boot seal, Round wall FRP, EPOXY REQ'D
<br />3/4 brass ground- ing rod F-07-GR-R 3/4" brass grounding rod, full-body with brass conductor and clamps, EPOXY REQ'D
<br />3 x 2" FRP F-32S-T-R 3x2" FRP, full-body taper by slip; dual test ports and single injection port, EPOXY REQ'D
<br />4 x 3" FRP F-43S-T-R
<br />4x3" FRP, full-body taper by slip; dual test ports and single injection port, EPOXY REQ'D
<br />6 x 4" FRP F-64S-T-R
<br />6x4" FRP, full-body taper by slip; dual test ports and single injection port, EPOXY REQ'D
<br />3 x 2" FRP F-32A-T-R
<br />3x2" FRP, adjustable full-body taper by slip; dual test ports and single injection port, EPOXY REQ'D
<br />4 x 3" FRP F-43A-T-R 4x3" FRP, adjustable full-body taper by slip; dual test ports and single injection port, EPOXY REQ'D
<br />NEW CONSTRUCTION FITTINGS
<br />3/4" PVC coated conduit 3/4" PVC coated conduit, doublewall full-body, duel injection ports and tertiary boot seal, F-07RS-0-DF
<br />Flat wall FRP, EPOXY REQ'D
<br />3 x 2" FRP F-32S-T-F 3x2" FRP, full-body taper by slip; dual test ports and single injection port, EPOXY REQ'D
<br />4x3" FRP, full-body taper by slip; dual test ports and single injection port, EPOXY REQ'DF-43S-T-F4 x 3" FRP
|