My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
2226
>
2300 - Underground Storage Tank Program
>
PR0548528
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2026 9:41:12 PM
Creation date
8/29/2025 4:52:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0548528
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0000370
FACILITY_NAME
ORLANDOS ESCALON
STREET_NUMBER
2226
STREET_NAME
JACKSON
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22727016
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
2226 JACKSON AVE ESCALON 95320
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Monitoring System Certification Form <br /> S. MONITORING SYSTEM AND PROGRAMMING <br /> A separate Monitoring System Certffication Form must be prepared for each control panel. <br /> Make of Monitoring System Model of Monitoring System software Version Installed <br /> Control Panel Control Panel <br /> Veeder Root TLS-450 01G.H. 33.53 <br /> Attach the post-certification reports if the rnonitoring system is capable of ge,,Ig Yes No NA <br /> either,` MMonitoring System Set-up ® ,alarm History Report <br /> Al monitoring equipment is operational per manufacturer's specifications' ❑ <br /> Secondary containment systems are free of damage, debris, or liquid? ® ❑ <br /> Are the audible and visual alarms operational? ® ❑ <br /> All sensors have been: 1) visually inspected for wiring kinks, breaks and residual � ❑ ❑ <br /> buildup on floats; and ) tested for functionality and confirmed operational? <br /> Are all sensors installed to detect a release at the earliest opportunity in the i <br /> ❑ <br /> secondary containment? _ <br /> The monitoring system set-up was reviewed, and proper settings confirmed? ❑ a <br /> Was the monitoring control panel's Backup battery visually inspected, functionally ER ❑ 0 <br /> tested, and confirmed operational? _ <br /> Does the F1 ow of fuel stop at the dispenser if a release is detected in the under- 0 ❑ ❑ <br /> dispenser containment? <br /> Does the turbine automatically smut down if the piping secondary containment 9 ❑ 0 <br /> monitoring system fails to operate or is electrically disconnected? <br /> Does the turbine automatically shut down if the piping secondary containment <br /> monitoring system detects a felease? Which sensors initiate positive shut down? ® ❑ ❑ <br /> (Check all that apply) 0 Sump ® UDC <br /> If monitoring system alarms are relayed to a remote monitoring center, is all ❑ ❑ 0 <br /> communication equipment operational" _ <br /> Describe all answers marked "ilio"or "Fail"and proposed remedy in Section 9. <br /> List all mon doring equipment either replaced or repaired in Section 9 <br /> Page 2 of <br />
The URL can be used to link to this page
Your browser does not support the video tag.