Activity Description Hazards/Conditions Targeted Minimum PPE <br /> Emergency Response and/or Initial • Potential for high hazard Level A (Downgrade/upgrade (Trelleborg, etc.) <br /> Entry/Assessment of Unknown - chemicals/ IDLH based on site based on knowledge of contaminants and monitoring <br /> Suspected High Hazard history/visual evidence with PID/FID, radiation detector, LEL/02 per HASP/ <br /> (Sites/Facilities): (visible/expected reactions, spills, SOSGs) <br /> • Air and Radiation Monitoring vapors, fumes, smoke, known Respirator: Scott or MSA Full Face <br /> Sweep releases, etc.). Suit Type: Encapsulating 'Tychem <br /> • Visual Assessment • No CBRN suspected. Responder/Responder CSM (with boot, hood, <br /> • Note Taking • Potential for chemical reactions. gloves)/ChemTape <br /> • Photo-documentation • Unknown physical hazards. Inner Glove: "Nitrite (6 mil min recommended) <br /> • Little/ no site background Outer Glove: "Neoprene, Nitrile, (28 mil min <br /> information or information recommended) <br /> suggesting high hazard. Outer Steel Toe/Steel Shank Boot: "'Tingley <br /> • Intrusive work possible. HazProof Model 82330 and rely on suit boot material <br /> • Potential for chemical for permeation protection. <br /> splash/contact. (ASTM F-2413/ANSI Z41) <br /> • Required Work Practice: DECON: Dry or soap &water: water source for <br /> Immediate PPE Change-out emergency DECON; other DECON agents on hand. <br /> (i.e., gloves, etc.) upon contact <br /> with chemicals. <br /> • Required Work Practice: Must <br /> follow standard air monitoring <br /> rotocol. <br /> 4 <br />