Laserfiche WebLink
Activity Description Hazards/Conditions Targeted Minimum PPE <br /> Hazardous Categorization Testing . Assumes known chemical Level B (Upgrade/Downgrade based on knowledge of <br /> (HAZCAT) classes and site contaminants and monitoring with PID/FID, radiation <br /> • Opening sample containers in situation/background. detector, LEL/02 per HASP/ SOSGs) <br /> controlled environment . No CBRN suspected. Respirator: Scott or MSA Full Face <br /> • Working with small sample • Assumes immediate suit Suit Type: 'Tychem CPF4 (with hood, boot) <br /> quantities in well ventilated area removal if contaminated and Inner Glove: "Nitrite <br /> • Conducting HAZCAT testing with frequent glove changes. Outer Glove: "Viton or 4-H (use surgie over the 4-H <br /> appropriate lab equipment . Required Work Practice: for dexterity) <br /> Immediate PPE Change-out Outer Steel Toe Boot: 'vTingley HazProof Model <br /> (i.e., gloves, etc.) upon contact 82330 or <br /> with chemicals. Steel Toe Boot Cover: vLatex HazMaster Booty and <br /> • Required Work Practice: Must rely on suit boot material for permeation protection. <br /> follow standard air monitoring Steel Toe/Steel Shank Boots: ASTM F-2413/ANSI <br /> protocol. Z41 <br /> DECON: Dry or soap and water; water source for <br /> emergency DECON and eyewash suggested <br /> 6 <br />