Laserfiche WebLink
Storage and Boom-Type Lifting or Hoisting Equipment Clearances Required from Energized Overhead High- <br /> Voltage Lines, provided below. <br /> Table 1: General Clearances Required from Energized Overhead-High Voltage Conductors <br /> Nominal Voltage (Phase to Phase) Minimum Required Clearance (Feet) <br /> 600 50,000 6 <br /> over 50,000 345,000 10 <br /> over 345,000 750,000 16 <br /> over 750,000 1,000,000 20 <br /> Table 2: Material Storage and Boom-Type Lifting or Hoisting Equipment Clearances Required from <br /> Energized Overhead High-Voltage Lines <br /> Nominal Voltage (Phase to Phase) Minimum Required Clearance (Feet) <br /> 600 50,000 10 <br /> over 50,000 75,000 11 <br /> over 75,000 125,000 13 <br /> over 125,000 175,000 15 <br /> over 175,000 250,000 17 <br /> over 250,000 370,000 21 <br /> over 370,000 550,000 27 <br /> over 550,000 1,000,000 42 <br /> 8.13.2 Subsurface Work <br /> Subsurface work activities will require adherence to Roux's Corporate Subsurface Utility Clearance <br /> Management program found within Appendix G. <br /> 8.14 Traffic Control <br /> Per Cal/OSHA T8 CCR Section 1598, if Site operations encroach upon public streets or highways and a <br /> hazard exists to Site personnel because of traffic conditions, a traffic control plan will be implemented in <br /> accordance with the California Department of Transportation's(DDT's) "California Manual on Uniform Traffic <br /> Control Devices for Streets and Highways" dated January 13, 2012. <br /> 5175.0001S102/HSP Site-Specific Health and Safety Plan I ROUX 135 <br />