Laserfiche WebLink
D.17. SHIPPING/TRANSPORTATION HAZMAT/DANGEROUS GOODS Applicable Not Applicable, Not Anticipated <br /> PART E-AIR MONITORING, WORKER EXPOSURE MONITORING <br /> E.1. AIR MONITORING ® Applicable ❑ Not Applicable, Not Anticipated <br /> Site-Specific Notes,Clarifications: PID used to monitor VOCs in the work area <br /> AIR-TESTING PARAMETERS-Select site-specific testing parameters;list associated equipment in Part C.2,Safety Equipment List. <br /> ®VOCs E ❑Oz(Oxygen)—oxygen meter ❑Particulates-total dust meter <br /> ®PID(Photoionization detector): 10.6 eV ❑LEL(Lower Explosive Level)-LEL meter ❑%Methane—methane meter <br /> ❑FID(Flame ionization detector) ❑HzS(Hydrogen Sulfide)—H2S detector O Calibration kit for each parameter <br /> ❑Colorimetric indicator tubes—describe above El CO(Carbon monoxide)—CO detector El Other: <br /> SUBSTANCE-SPECIFIC(PRE-SET)ACTION LEVELS-Sustained breathing zone action levels sustained general work-area levels for LEL). <br /> 19.5-23% Acceptable to continue work without Oz-focused respiratory protection. <br /> Oz <19.5% r STOP WORK,ventilate to raise Oz to>19.5%for re-entry. For persistent hazard,contact Corp.HSE Dept. <br /> (Oxygen) <br /> Yg ) >23.0% STOP WORK,ventilate to lower 02 to<23%for re-entry. For persistent hazard,contact Corp.HSE Dept. <br /> IMPORT_ANT__: Confirm sufficient oxygen is present(min.8-12%)to ensure accurate LEL_r_e__a__d__i_n__gs__. <br /> LEL(Lower <10%LEL Acceptable to continue working in work area;continue to monitor LEL. <br /> Explosive Limit) u STOP WORK. Implement controls(reposition workers,ventilate,contain/eliminate source,etc.);resume <br /> >10%LEL work ONLY when LEL readings are<10%,sustained. <br /> <1 ppm E Acceptable to continue work without H2S-focus ed respiratory protection. <br /> r Implement controls(reposition workers,ventilate,contain/eliminate source,scheduling,etc.)to limit <br /> Hz5 E 1-10 ppm E exposures to<1ppm,or use APR*with VOC/acid-gas cartridges(yellow);do not exceed MUC*for respirator <br /> ❑ type;confirm acceptability of respirator usage with HSE Dept. <br /> (Hydrogen Sulfide) - - - - - --- ----------------------------------------- ------------------------------------------------------------------------------------- <br /> --- - ----------- ----------- <br /> Implement controls(reposition workers,ventilate,contain/eliminate source,scheduling,etc.)to limit <br /> >10 ppm exposures to<10ppm(with respirator),or<lppm(without respirator). For persistent levels>10 ppm,STOP <br /> WORK,contact task lead,PM or HSE Dept. <br /> CO <25 ppm Acceptable to continue work without CO-focused respiratory protection. <br /> ❑ (Carbon >25 ppm Implement controls(reposition workers,ventilate,contain/eliminate source,scheduling,etc.)to limit <br /> Monoxide) — exposures to<25ppm. For persistent levels>25ppm,STOP WORK,contact PM and/or HSE Dept. <br /> WILDFIRE <150 In this Air Quality Index(AQI)range,it's acceptable to continue work without respiratory protection. <br /> ❑ SMOKE 151-500 Voluntary use of N95 respirator is appropriate. <br /> (AQI for PM 2.5) >500 STOP WORK,or use APR*with approval of HSE Dept. <br /> ❑ <OTHER> -- ---- <br /> SITE-DERIVED ACTION LEVELS—Sustained breathing zone action levels;derived based on site contaminants;REVIEW WITH CORP.HSE DEPT.REQUIRED. <br /> <1.0 ppm Acceptable to continue work without VOC-focused respiratory protection. <br /> „ Implement controls(reposition workers,ventilation,containment,eliminate source,etc.) to lower VOC <br /> VOCs > ppm exposures to less than specified action level,or use APR*with approval of Corp.HSE Dept. <br /> ® (Volatile Organic Use APR*with VOC cartridges(yellow or black);do not exceed MUC**for respirator type;confirm <br /> ComCompounds) X—Xppm <br /> P ) ;procedures for respirator usage with HSE Dept. <br /> >1.0 ppm i STOP WORK. Implement controls(reposition workers,ventilation,containment,eliminate source,etc.),for <br /> persistent levels greater than action contact PM and/or HSE Dept. <br /> <X mg/m3 Acceptable to continue work without particulate-focused respiratory protection. <br /> AIRBORNE > mg/ma Implement controls(water spray,reposition workers,ventilation,containment,etc.)to lower dust levels to <br /> DUST --------------- less than specified action level,or use APR*with approval of HSE Dept. <br /> ❑ X to X mg/m3 i Use APR*with particulate cartridges appropriate for the hazard;do not exceed MUC**for respirator type; <br /> (Total :confirm procedures for respirator usage with HSE Dept. <br /> Particulates) ----------------�----�---------------- ----------- -----------------------------p----------------g------------------------ --------------------------------------------------------------------------------------------- <br /> g/ 3 STOP WORK. Implement controls. For persistent levels greater than action level,contact PM and/or Corp <br /> HSE Dept. <br /> ❑ <OTHER> <br /> *Air-purifying respirator ** Maximum use concentration <br /> .......................................................................................................... ............................................................................................................................................................................ <br /> HSE Program Documents: HSE SOP-460:Field Site Exposure Monitoring,HSE SOP-464:Lead Exposure Control, <br /> HSE SOP-466:Hydrogen Sulfide Exposure Control,Wildfire Smoke THA Addendum <br /> E.2. OTHER WORKER EXPOSURE MONITORING/SAMPLING ❑ Applicable ® Not Applicable, Not Anticipated <br /> E.3. FENCELINE/PERIMETER AIR MONITORING ❑ Applicable ® Not Applicable, Not Anticipated <br /> Project/Task Name:Groundwater Gauging and Sampling THA ver.4.0 <br /> GeosMtec° THA Date:4/17/2025 Page 16 <br /> consultants <br />