My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2905
>
2300 - Underground Storage Tank Program
>
PR0231952
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/1/2026 2:43:06 PM
Creation date
9/26/2025 1:41:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231952
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0003712
FACILITY_NAME
CHEVRON STATION #94275*
STREET_NUMBER
2905
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09760004
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
2905 W BENJAMIN HOLT DR STOCKTON 95207
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN Environmental Health Department <br /> —COUNTY <br /> Greatness grows here. <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CHEVRON STATION #94275* 12905 W BENJAMIN HOLT DR, STOCKTON December 15, 2025 <br /> 76 CCR 2630, 2632, 2643, 2030015-Facility demonstrated that methods used to monitor the UST system ❑OUT ❑ R ❑COS <br /> 2644.1 complies with standards (TCR 9d) <br /> 77 CCR 2712(f) 2030073- Facility has corrected cited violations within 30 days of receiving report ■OUT ❑ R ❑COS <br /> 78 CCR 2650(e), 2652 2030077-Owner/Operator notified/prepared report upon discovery of unauthorized ❑OUT ❑ R ❑COS <br /> release (TCR 9d) <br /> 79 CCR 2717.1(g) 2030045- Red Tag information is legible and has not been removed or tampered ❑OUT ❑ R ❑COS <br /> with <br /> 80 CCR 2717.1(f); HSC 2030044-Facility did not deposit/allow deposit of petroleum or a hazardous ❑OUT ❑ R ❑COS <br /> 25292.3(c) substance into a red tagged UST <br /> 81 HSC 25292.3(c)(1)(C) 2030079- Facility did not dispense petroleum or a hazardous substance from a ❑OUT ❑ R ❑COS <br /> UST that has been red tagged <br /> 82 CCR 2670(b)(e)(f), 2671 2030063- Facility is in compliance with temporary closure requirements ❑OUT ❑ R ❑COS <br /> 83 HSC 25298(c); CCR 2030038- UST system properly closed and complies with permanent closure ❑OUT ❑ R ❑COS <br /> 2670, 2672 requirements <br /> 84 HSC 25392.4(d), 25292.5 2030066-Repaired/retested any leaks found when ELD testing a UST within 1,000 ❑OUT ❑ R ❑COS <br /> (c) feet of a public water well <br /> 85 CCR 2631(a); HSC 2060027-Tank system primary containment is constructed, operated, and ❑OUT ❑ R ❑COS <br /> 25290.1(c) maintained product-tight. <br /> 86 CCR 2631.1, 2660(m) 2060024- UST system is made of or lined with materials that are compatible with ❑OUT ❑ R ❑COS <br /> the substance stored. <br /> 87 CCR 2631(c), 2662(d) 2060021 -Striker plate installed and positioned correctly. ❑OUT ❑ R ❑COS <br /> 88 CCR 2631(b&d), 2666 2060007-Primary and secondary containment designed and constructed to an ❑OUT ❑ R ❑COS <br /> (b&e) engineering specification. <br /> 89 HSC 25290.10) 2060008- Enhanced leak detection testing performed before the tank is placed in ❑OUT ❑ R ❑COS <br /> use <br /> 90 CCR 2666(b)(2) 2060029-SW piping has been upgraded to continuously monitored DW piping ❑OUT ❑ R ❑COS <br /> when replacement or repair needed <br /> 91 HSC 25291(e) 2010-Administration/Documentation-General ❑OUT ❑ R ❑COS <br /> 92 - 2015-Administrative/Documentation-General Local Ordinance ❑OUT ❑ R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR-Notice to Comply) <br /> Item# Remarks <br /> Overall Inspection Comments <br /> Routine UST inspection <br /> An inspection checklist was provided to the facility operator at the time of inspection. The inspector will provide a <br /> complete report to the facility operator within the next few weeks. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting paperwork, <br /> within 30 days of receiving the complete inspection report. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING THIS <br /> FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: 12/15/2025 Inspector: Inspector Phone: <br /> Printed Name and Title: Stacy Rivera, Lead Senior REHS (209)616-3043 <br /> Kenisha Jenkins, Store Manager <br /> EHD-CUPA Inspection Report IS02 Page 4 of 4 FA0003712 PR0231952 4588104 12/15/2025 <br /> a <br /> CP22-UST FULL g <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.