Laserfiche WebLink
J <br /> Environmental Health Department <br /> A N 0 A 0 U I N <br /> t� : -�'o-- C:0U N TY <br /> Y � + Greatness grows here. <br /> Swimming Pool Official Inspection Report <br /> Name of Facility:MOTEL 6#1323 Date: 06/16/2025 <br /> Address: 6717 PLYMOUTH RD, STOCKTON 95207 <br /> Owner/Operator: MOTEL 6 Telephone: ()- <br /> Program Element: 3611 - PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: Routine Reinspection on or after: <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public <br /> health and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #24 VGB Suction Covers MAJC <br /> OBSERVATIONS:The equalizer line cover was lacking. Install cover today. Close pool area until the corrections are made <br /> and verified by this department. (REPEAT) <br /> CALCODE DESCRIPTION:All suction outlets shall be equipped with suction covers that meet the applicable ANSI/APSP-16 <br /> performance standards. (CBC 3137B) <br /> This is(Major)Violation. <br /> #3 Safety Signs <br /> OBSERVATIONS:A sign on the entrance gate that says "Keep Gate Closed"is lacking. Post sign today. (REPEAT) <br /> CALCODE DESCRIPTION:Pool operator shall keep safety signs well maintained.(CCR 65535)Safety signs shall have clearly legible <br /> letters or numbers not less than 4 inches high,unless otherwise specified.Safety signs shall be affixed to a wall, pole,gate,or similar <br /> permanent structure in a location visible to all pool users,unless otherwise specified.(CBC 3120B) <br /> This is(Minor-Food)Violation. <br /> #9 Ladders and Handrails <br /> OBSERVATIONS:Both deep end hand rails were observed loose. Tighten hand rails today. (REPEAT) <br /> CALCODE DESCRIPTION:A means of entry and exit shall be provided at both the shallow and deep end of the pool.Ladders and <br /> handrails shall be corrosion resistant and shall be rigidly installed.At least one handrail shall extend from the deck to not less than a <br /> point above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck.(CBC 3111 B) <br /> Pool operator shall keep ladders and handrails well maintained.(CCR 65535) <br /> This is(Minor-Food)Violation. <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:The skimmer is lacking a weir. Install all parts to the skimmer within three days. (REPEAT) <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall <br /> be maintained in accordance with manufacturer specifications.(CBC 3136B) <br /> This is(Minor-Food)Violation. <br /> PR0360001 06/16/2025 <br /> EHD 36-01 Rev.09/16/2020 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />