Laserfiche WebLink
Case Narrative <br /> Client: Patriot Environmental Services Job ID: 720-93886-1 <br /> Project/Site: UPRR-French Camp <br /> Job ID: 720-93886-1 -- - - -- <br /> Laboratory: Eurofins TestAmerica, Pleasanton <br /> Narrative <br /> Job Narrative <br /> 720-93886-1 <br /> Comments <br /> No additional comments. <br /> Receipt <br /> The samples were received on 7/6/2019 11:20 AM;the samples arrived in good condition, properly preserved and,where required, on ice. <br /> The temperature of the cooler at receipt was 4.6°C. <br /> Receipt Exceptions <br /> The Chain-of-Custody(COC)was incomplete as received and/or improperly completed:sample date and time not written on the COC. <br /> Information acquired from tops of jars. <br /> GC/MS VOA <br /> Method(s)8260B:The continuing calibration verification(CCV)associated with batch 440-556795 recovered above the upper control limit <br /> for 2,2-Dichloropropane. The samples associated with this CCV were non-detects for the affected analytes;therefore,the data have been <br /> reported. The following samples are impacted: 001 (720-93886-1), 002(720-93886-2)and(CCVIS 440-556795/2). <br /> Method(s)8260B: Surrogate 4-Bromofluorobenzene recovery for the following sample was outside control limits:002(720-93886-2). <br /> Evidence of matrix interference is present;therefore, re-extraction and/or re-analysis was not performed. <br /> No additional analytical or quality issues were noted,other than those described above or in the Definitions/Glossary page. <br /> GC/MS Semi VOA <br /> Method(s)8270C:The following samples required a dilution due to the nature of the sample matrix: 001 (720-93886-1)and 002 <br /> (720-93886-2). Because of this dilution,the surrogate spike concentration in the sample was reduced to a level where the recovery <br /> calculation does not provide useful information. <br /> Method(s)8270C:The following samples were diluted due to the nature of the sample matrix: High hydrocarbons 001 (720-93886-1)and <br /> 002(720-93886-2). Elevated reporting limits(RLs)are provided. <br /> Method(s)8270C:The source sample was diluted due to the nature of the sample matrix: (LCS 440-556805/2-A). Because of this dilution, <br /> the surrogate spike and matrix spike concentration in the sample was reduced to a level where the recovery calculation does not provide <br /> useful information. <br /> No additional analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page. <br /> GC VOA <br /> No analytical or quality issues were noted, other than those described in the Definitions/Glossary page. <br /> GC Semi VOA <br /> Method(s)801513:The following 8015-DRO samples required a dilution due to the nature of the sample matrix: 001 (720-93886-1)and <br /> 002(720-93886-2). Because of this dilution,the surrogate spike concentration in the sample was reduced to a level where the recovery <br /> calculation does not provide useful information. <br /> No additional analytical or quality issues were noted,other than those described above or in the Definitions/Glossary page. <br /> Metals <br /> Method(s)6010B:The matrix spike/matrix spike duplicate(MS/MSD)recoveries and precision of Barium and Zinc for preparation batch <br /> 440-557085 and analytical batch 440-557455 were outside control limits. Sample matrix interference and/or non-homogeneity are <br /> suspected because the associated laboratory control sample(LCS)recovery was within acceptance limits. <br /> No additional analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page. <br /> Eurofins TestAmerica, Pleasanton <br /> Page 4 of 37 7/15/2019 <br />