Laserfiche WebLink
Case Narrative <br /> Client: GHD Services Inc. TestAmerica Job ID: 720-90502-2 <br /> Project/Site: UPRR- French Camp <br /> Job ID: 720-90502-1 <br /> Laboratory: TestAmerica Pleasanton <br /> Narrative <br /> Job Narrative <br /> 720-90502-1 <br /> Comments <br /> No additional comments. <br /> Receipt <br /> The samples were received on 12/21/2018 1:45 PM;the samples arrived in good condition, properly preserved and,where required, on <br /> ice. The temperature of the cooler at receipt was 5.5°C. <br /> GC/MS VOA <br /> Method(s)8260B:The following sample was diluted due to matrix.: HYD.WASTE(720-90502-5). Elevated reporting limits(RL)are <br /> provided. <br /> No additional analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page. <br /> GC Semi VOA <br /> Method(s)801513:The following sample required a dilution due to the nature of the sample matrix: HYD.WASTE(720-90502-5). Because <br /> of this dilution,the surrogate spike concentration in the sample was reduced to a level where the recovery calculation does not provide <br /> useful information. <br /> No additional analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page. <br /> Metals <br /> Method(s)6010B:The matrix spike/matrix spike duplicate(MS/MSD)recoveries for in preparation batch 720-257627 and analytical batch <br /> 720-257691 were outside control limits. Sample matrix interference and/or non-homogeneity are suspected because the associated <br /> laboratory control sample(LCS)recovery was within acceptance limits. <br /> Method(s)6010B:The serial dilution performed for the following sample associated with batch 720-257691 was outside control limits <br /> Ba-26%, Co-40%, Cr-29%, Ni-31%,V-23%: (720-90512-A-1-ESD 120) <br /> No additional analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page. <br /> Organic Prep <br /> Method(s)3546: 8015B DRO 3546. Due to the matrix, the following sample could not be concentrated to the final method required volume <br /> of 2 mL: HYD.WASTE(720-90502-5). The reporting limits(RLs)are elevated proportionately.The sample final volume was 5 mL. <br /> No additional analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page. <br /> Job ID: 720-90502-2 -- - -- <br /> Laboratory: TestAmerica Pleasanton <br /> Narrative <br /> Job Narrative <br /> 720-90502-2 <br /> Comments <br /> No additional comments. <br /> Receipt <br /> The samples were received on 12/21/2018 1:45 PM; the samples arrived in good condition, properly preserved and,where required, on <br /> ice. The temperature of the cooler at receipt was 5.5°C. <br /> No analytical or quality issues were noted, other than those described in the Definitions/Glossary page. <br /> TestAmerica Pleasanton <br /> Page 4 of 43 1/24/2019 <br />