TestAmerica ASL Lab 1100 NE Circle Boulevard, Suite 310 <br /> Corvallis, Oregon 97330 <br /> THE LEADER IN ENVIRONMENTAL TESTING 541-207-0995 <br /> California State Environmental Laboratory Accreditation Program, <br /> Certificate No.: 1726 <br /> Client: TA Pleasanton Report Date: j / 1 /20 <br /> Sample ID: HYD.WASTE ASL Lab ID: B4203 -01 <br /> TestAmerica Job Number: 720-90502-2 <br /> The following information was taken from the Static Acute Bioassay Procedures for Hazardous Waste Samples,California <br /> Department of Fish and Game Water Pollution Control Laboratory(November 1988). <br /> Acute toidcity: <br /> •"Bioassays designed to assess waste toxicity under the Hazardous Waste Criteria Regulations should preferably be <br /> conducted with fathead minnows ...Alternate species are the golden shiner... and the rainbow trout." <br /> •"Section 66696 specifies that the waste generator shall demonstrate that the waste does not have an LC50 less than 500 <br /> mg/L in order to qualify for a nonhazardous designation on the basis of aquatic toxicity." <br /> •"When screening bioassays are performed,initial screening bioassays must be conducted at two concentrations bracketing m <br /> the 500 mg/L level." <br /> •"Serial dilution bioassays to determine the LC50 and associated confidence limits are conducted on those samples which <br /> cause mortality of 40 percent or greater at 750 mg/L in the screening bioassay." <br /> A "PASS" result indicates an LC50 value of greater than or equal to 500 mg/L. <br /> The sample qualifies for a nonhazardous designation <br /> A "FAIL" result indicates an LC50 value of less than 500 mg/L. <br /> The sample does not qualify for a nonhazardous designation <br /> Test results: (only one to be selected) <br /> PASS LC50 > 750 mg/L <br /> ( >60% alive(12 or more of 20 organisms)in the 750 mg/L concentration.) <br /> PASS LC50 > 500 mg/L <br /> ( Based on statistical analysis using CETIS,when>45%survival @ 400 mg/L and<55%survival @ 750 mg/L ) <br /> Note: Retesting with the definitive method may produce a more refined LC50 value. <br /> FAIL LC50 < 500 mg/L <br /> ( Based on statistical analysis using CETIS,when>45%survival @ 400 mg/L and<55%survival @ 750 mg/L ) <br /> Note: Retesting with the definitive method may produce a more refined LC50 value. <br /> FAIL LC50 < 400 mg/L <br /> ( <40% alive(8 or fewer of 20 organisms)in the 400 mg/L concentration.) <br /> Senchsheets-California HazWaste(ASL1277.1218)Single sample Doc ConiroliD:ASL1277-1218 <br /> Page 29 of 43 1/24/2019 <br />