Laserfiche WebLink
n. CALIFORNIA FIRE CODE (CFC): The following CFC requirements will be applicable to the <br /> proposed project. The following conditions shall be addressed prior to submittal of a building permit <br /> application to the Building Department: <br /> 1. CFC, Section 503 Fire Apparatus Access Roads-Shall be provided as required by this section. <br /> 503.1.2 -A secondary access may be required. <br /> 2. CFC, Section 1205 Solar Photovoltaic Power Systems-Follow this Chapter. <br /> o. BUILDING DIVISION: The following commercial building permit submittal requirements shall be <br /> met: <br /> 1. Application Submittal Policy: <br /> a. Permit Scope: A Building Permit is required for all proposed new structures. <br /> b. Professional Credentials:All Plans must be prepared,signed,and stamped by a California- <br /> registered civil engineer or licensed architect. <br /> c. Construction Documents: Comprehensive construction plans must be provided. <br /> 2. Mandatory Site Plan Elements (See Site Plan Checklist for required information): <br /> a. Civil Engineering: Comprehensive storm drainage systems and grading details. <br /> b. Access & Parking Infrastructure: Detailed parking and paths of travel layouts, including <br /> standard and code-compliant accessible vehicle parking stalls. <br /> c. Utilities & Landscaping: On-site electrical distribution, all existing and proposed utility <br /> services, and required landscaping. <br /> 3. Architectural & Systems Plan Criteria - Architectural designs must verify compliance with <br /> current California building codes. Plans must illustrate all interior and exterior spaces, including: <br /> a. Spatial Classifications: Occupiable and habitable rooms, hallways, courtyards, assembly <br /> spaces, and storage areas. <br /> b. Life-Safety & Accessibility: Site amenities, public/private restroom facilities, emergency <br /> paths of travel for egress, and accessibility features. <br /> c. Mechanical, Electrical, & Plumbing (MEP): Fully integrated designs for HVAC, plumbing, <br /> and electrical systems engineered to support all proposed spaces. <br /> 4. Geotechnical Documentation: <br /> a. Soils & Foundation Investigation: foundation and soils investigation reports shall comply <br /> with Chapter 18 of the California Building Code. <br /> p. MITIGATION MONITORING AND REPORTING PROGRAM: The project shall comply with all <br /> required mitigations included in the MMRP dated September 24, 2026. <br /> PA-2500218—Conditions of Approval 3 <br />