REVISIONS W <br /> SOLAR ARRAY, INVERTER AND TRANSFORMER TO MEDIUM VOLTAGE OUTPUT TO UTILITY U) <br /> EQUIPMENT AREA #1 I EQUIPMENT AREA #2 PRELIM LAYOUT 08/14/25 0 <br /> ( ) XFMR 1 <br /> N PV SWITCHGEAR 1 P01 PRELIM LAYOUT 07/31/25 <br /> INV-01 3000A, 80OV, 3�, 4W, NEMA3R, 800V WYE /12kV DELTA I 38.044912% - 121 .095931 ° <br /> CPS SCH275KTL-DO/US INVERTER of <br /> 250KW, 800VAC, 1500VDC MAIN BREAKER W/ TRANSFORMER >_ <br /> ANTI—ISLANDING IEEE 1547 COMPLIANT, METERING SECTION 3000KVA w/ FUSE/DISCONNECT TO PG&E 12KV o <br /> UL 1741 SA LISTED _ _ _ _ _ Z=5% _ _ _ FEEDER NAME: LINDEN 1 103 0 <br /> - - - - - - - - - - <br /> SOURCE CIRCUIT (TYP. OF 12) T - - -31 0 <br /> _ _ _ _ _ NEW 3-PHASE OVERHEAD WIRE <br /> 05 PANELS / STRING I I 3000A I I Y ACURRENT I I <br /> 119/120 STRINGS / INV — I I 3P I I LIMITING I BY UTILITY <br /> 60HZ FUSE <br /> I <br /> I <br /> I INVERTER I I I <br /> I I <br /> BREAKER I 1250A, 3P 1 i I BREAK I I o �L AD m g <br /> 1 I I SWITCH I I I W M -t � o <br /> FROM OTHER N TO SCADA LOOP 1 250A, 3P I GFP 1 3 I POLE- 1 w rn co L <br /> SOURCE CIRCUITS i <br /> ( )10.2KV MCOV I I � <br /> I 1 SURGE <br /> 250A, 3P I I ARRESTOR I UTILITY SCADA 1 52 I ~ <br /> - - - - - - I RECLOSER I I Q ~ w o w <br /> _ I w v w z <br /> FROM OTHER ' 1 ' I I I L - - - - - - J W UJ <br /> � Q O <br /> STRING <br /> SOURCE CIRCUIT . I . I METER TEST a U) � a <br /> INVERTERS I W >_ w <br /> 05 PANELS / STRING I250A 3P I I N25' SWITCH (TYP.) O w z <br /> 119/120 STRINGS / INV — 1 -� <br /> INVERTER I i 250A, 3P I i W O � <br /> 0 <br /> AC I I I POLE-2 F- - - - - - - - - - - - - a z <br /> BREAKER I 1250A, 3P I I I p <br /> FROM OTHER I I I UTILITY REVENUE METER I I <br /> ,,, TO SCADA LOOP I I I POINT OF COMMON COUPLING(PCC) I O <br /> SOURCE CIRCUITS 125A, 3P I I I I I o <br /> I I I I CAISO I Q <br /> - - - - - - L - - - - - - - - - - - - - ' I BACKUP I C/) <br /> INV-12 I I METER <br /> I I 1 co co <br /> AUX PANEL I O 800V AUX PANEL z <br /> 480V 120/240V z w v 00 <br /> 0 <br /> POLE-4 CAISO o > Y N w <br /> 480V 3�/3W F120/240V 1 /3W r - - - - - - - - 7 I METER I � w a z <br /> UTILITY AC DISCONNECT 15KV, I 1 z cD <br /> 600A, 3x, ACCESSIBLE WITH i i cy a oz w <br /> 40A/2P 40A/2P I 1 1 Q 0 Q <br /> z a <br /> LOCK PROVISION I PG&E 1 Q ca -1 o <br /> FOR DAS, II AND VISIBLE BLADE I METER I o N <br /> FOR ATI ^ LIGHTING, <br /> TRACKER ^ OUT,LETS Iod <br /> INERTIA LI N EBOSS i <br /> I I n <br /> L26SLSUG 1 423P4 II II (D C/) <br /> GANG OPERATED AIR L_ - - - - z w <br /> L - - - - - - - - J - - - - - - - - - - - - - - a w z a <br /> BREAK SWITCH <br /> f) zLD0 <br /> V) Cy (D co c) <br /> wzwcn <br /> Co W a Q <br /> (3)-1/C, #3/0 AWG, AL, 15KV PROJECT <br /> AAAC OVERHEAD WIRE <br /> �25' <br /> i <br /> POLE-3 L.L <br /> CUSTOMER RECLOSER WITH J o <br /> 0 <br /> PROTECTION RELAY (SEL 651 R) <br /> U) U (� <br /> - - - - - - - - - - - - - - - - - - - - - - - <br /> 0 U � <br /> I I Q <br /> c <br /> 52 O O <br /> Op N <br /> ZU � � cy) � <br /> Q W z N <br /> I I 0 C'7 W L(� <br /> 1 59 059N 51G I Z (y) Q L0 Z <br /> I 27 81U 79 51C I � � Z Q <br /> 00 Q O <br /> 0 r-- J U J J <br /> SYSTEM SPECIFICATIONS I <br /> SHEET TITLE <br /> SYSTEM SIZE DC 3,810.70 kW 1 AC I/P, DC O/P 1 <br /> SYSTEM SIZE AC 3,000.00 kW POWER SUPPLY <br /> DC/AC RATIO 1 .27 <br /> MODULE MANUFACTURER FIRST SOLAR <br /> MODULE MODEL FS-753OA—TR1 1 SEE NOTE 5 1 <br /> MODULE RATING 530 W 1 (BATTERY <br /> 1 BACKUP) 1 <br /> TOTAL MODULE QTY 7,190 1 UPS-3 1 <br /> MODULES PER STRING 5 <br /> TOTAL NO. OF STRINGS 1 ,438 1 1 S N G L E LINE <br /> INVERTER MODEL CPS SCH275KTL—DO/US J <br /> DIAGRAM <br /> INVERTER RATING 250 kW <br /> GENERAL NOTES <br /> INVERTER QTY 12 <br /> STEP—UP TRANSFORMER 800V WYE /12KV DELTA, 3000kVA 1 . AC MV CIRCUITS SHALL BE INSTALLED AND INTERCONNECTED WITH UTILITY, PER UTILITY SPECIFICATIONS. <br /> 2. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE 2023 EDITION OF NATIONAL ELECTRIC CODE. <br /> 3. ALL DC AND AC EQUIPMENT, WHERE APPLICABLE, SHALL BE LISTED AND LABELED PER RECOGNIZED ELECTRICAL <br /> TESTING LABORATORY AND INSTALLED PER THE LISTING REQUIREMENTS, THE MANUFACTURER'S INSTRUCTIONS AND IN <br /> ACCORDANCE WITH NEC. <br /> S 1 N G � E LINE DIAGRAM 4. RECLOSER CONTROL SETTINGS TO BE COORDINATED WITH UTILITY AND CONTRACTOR.5. RELAY TO BE PROVIDED WITH 8—HOUR BATTERY BACK—UP. <br /> 6. UTILITY RIG, METER, WEATHER STATION AND ASSOCIATED COMMUNICATIONS EQUIPMENT TO BE PROVIDED WITH BATTERY SCALE: AS SHOWN <br /> BACK—UP PER UTILITY REQUIREMENTS. DRAWN: LR <br /> 7. ALL BREAKERS AND DISCONNECT SWITCHES ARE CLOSED UNDER NORMAL OPERATING CONDITIONS UNLESS OTHERWISE <br /> NOTED. DATE: 08/14/25 <br /> 8. THIS DRAWING REPRESENTS A CONCEPTUAL INTERCONNECTION SCHEME. THE INTENT IS TO COMMUNICATE PROJECT <br /> SPECIFIC EQUIPMENT, SIZE AND NEGOTIATE THE INTERCONNECTION DETAILS WITH THE UTILITY. THIS DRAWING HAS NOT <br /> BEEN ISSUED FOR CONSTRUCTION PURPOSES. THE DEVELOPER OR CONTRACTOR IS RESPONSIBLE FOR ENSURING A NOT FOR CONSTRUCT0N , E 10 1 <br /> FOR A D SCUSS 0 O Y , SYSTEM DESIGN IS COMPLETE AND APPROVED BY AN APPROPRIATELY LICENSED ENGINEER PRIOR TO PROCUREMENT AND CONSTRUCTION. <br /> SHEET 2 OF 2 <br /> THIS DRAWING AND ITS CONTENTS ARE THE PROPERTY OF SEQUOIA ENGINEERING AND DESIGN ASSOCIATES AND MAY NOT BE USED OR REPRODUCED WITHOUT WRITTEN PERMISSION. <br />