My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU-2500862
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
1973
>
2600 - Land Use Program
>
SU-2500862
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2026 8:49:04 AM
Creation date
10/30/2025 3:00:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU-2500862
PE
2626 - CONDITIONAL USE GENERAL (C)
STREET_NUMBER
1973
Direction
W
STREET_NAME
TURNER
STREET_TYPE
RD
City
LODI
Zip
95242
APN
01305017
CURRENT_STATUS
Closed - Issued
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
1973 W TURNER RD LODI 95242
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REV1510N5 BY <br /> PROPOSED FACILITY EFOR . <br /> SP Ts�*�T 1K R R A TskIIIo*T C H I T'IIIIIII%kT Cm <br /> 1973 W TURNER RD <br /> oai n SSL <br /> Lucaa s Winery <br /> J <br /> x � wCQn <br /> I WTu TumerRd Nostra VRa r E--4 <br /> M I <br /> z Family Winery ILI ^ L� � <br /> � co <br /> Z z �. <br /> o0 <br /> NORTH W w x � <br /> VICINITY MAP F U <br /> NTS. 0 1-4Z <br /> PRO.�ECT DATA EX I STING BU I LD I NGS: FUTURE BU I LD I NGS: I w o x <br /> a a <br /> PROJECT OWNER SPENKER RANCH INC. BUILDING #I BUILDING #14fY4OOD5R I DGS I RR I GAT I ON DISTRICT <br /> 1q15 W TURNER RD TASTI N6 ROOM, STORAGE POLE EARN STYLE ROOF COYER <br /> — — — — — — — — — — — — <br /> LODI, GA 415242 OCCUPANCY M/FI/51 OCCUPANCY A2 113010.0' <br /> CONST. TYPE VB CON5T. TYPE VB <br /> PROJECT LOCATION Iq13 W TURNER RD FIRE SPRINKLERS NO FIRE SPRINKLERS YES <br /> LODI, CA 415242 STORIES ONE 5TORIE5 ONE <br /> AREA 1,6401 S.F. AREA 2,800 S.F. I � <br /> APN 015-050-1-7 <br /> 015-050-15 <br /> 13-050-1- <br /> 013-050-15 BUILDING #2 BU I Ln I N6 #20 <br /> I <br /> SHOP, RESTROOM WINERY PROCESSING BUILDING <br /> PROJECT DESCRIPTION FACILITY EXPANSION OCCUPANCY 5/51 OCCUPANCY 52/F2 #14 (E) 50' x 80' <br /> CON5T. TYPE VB CON5T. TYPE IIB I GREEN HOU5E <br /> FIRE SPRINKLERS NO FIRE SPRINKLERS NO I _ — I #15 (E) 20' x 60' <br /> CODE COMPLIANCE STORIES ONE STORIES ONE I GREEN HOUSE <br /> AREA 843 S.F. AREA 8,000 S.F. (E) FLOWER <br /> FARM #I6 (E) IS' x:20, <br /> ALL WORK PERFORMED SHALL BE IN ACCORDANCE TO 5U I LD I NG #4 BUILDING #21 STORAGE <br /> THE LATEST EDITION OF APPLICABLE CODES, INCLUDING - <br /> BUT NOT LIMITED T0: MODULAR OFFICE ROOF COYER/ SOLAR PANEL 1 I #I'1 (E) 50' x 60' I ~ <br /> • 2022 CALIFORNIA BUILDING GORE, (GBG) OCCUPANCY B SUPPORT STRUCTURE I �I �BARN <br /> CONST. TYPE VB OCCUPANCY F2 <br /> • 2022 CALIFORNIA ELECTRICAL CODE, (GEC) I SEE ENLARGED Z <br /> FIRE SPRINKLERS NO CONST. TYPE IIB 51 TE PLAN <br /> • 2022 CALIFORNIA GREEN BUILDING CODE, (0650) #13 (E) 55' x 40' #IS (E) 8' x 40' <br /> STORIES ONE FIRE SPRINKLERS NO I SHIPPING CONTAINERS <br /> • 2022 CALIFORNIA MECHAN I CAL CODE, (CMG) AREA 1,344 S.F. STORIES ONE ( 8 01 BAR <br /> • 2022 CALIFORNIA PLUMB 1 NG CODE, (GPC) AREA 41,600 s.F. I 4 70 ° [:] 'JO I I I � , Z <br /> • 2022 CALIFORNIA ENERGY GORE, (CEG) BUILDING #I I I D 6 o- w } 13 <br /> • 2022 CALIFORNIA FIRE CODE, (CFC) STALL BARN ,AND NOT USED BUILDING #22 I I o E 101 �5 1 I I I #12 (E) 12' x 56' I ~ 0C ~ <br /> • 2022 CALIFORNIA HISTORICAL BUILDING CODE 21 � MODULAR ~ v � � } <br /> • 2022 CALIFORNIA EX I STING BUILDING GORE AS PART OF WINERY OPERATION SHIPPING CONTAINER FOOD SERVICE I � I Z(E) 24' x 30' <br /> • 2022 CALIFORNIA REFERENCED STANDARDS CODEW/ COMMERCIAL KITCHEN-NO DINING INSIDE <br /> 5U I LD I N6 #12 OCCUPANCY B I I 101 El <br /> 3 El I STAGE <br /> MODULAR OFFICE USED FOR EVENTS CON5T. TYPE 75 <br /> OCCUPANCY B FIRE SPRINKLERS NO O I o f .. I I ��(E) EVENT OVER —� <br /> CONST. TYPE VB 5TORIE5 ONE FLOW PARKING <br /> I Q IEl <br /> I Q <br /> FIRE SPRINKLERS NO AREA 320 S.F. <br /> 1,2'15.00 <br /> STORIES ONE BUILDING #23 �0 I v O <br /> AREA (612 5.F. N (E) FARM - <br /> TWO SHIPPING CONTAINERS WITH A FABRIC I ROADS I I COTTON TAIL LANE 0 z <br /> BUILDING #15 THRU #15 ROOF BETWEEN - MAINTENANCE BUILDING l J 6 <br /> STORAC7E FOR AC7 OPERATION ?SND NOT '"/ STORAGE I n > < � <br /> USED AS PART OF WINERY OPERATIONS OCCUPANCY 51 1 1,2"75.0' Q X <br /> CONST .TYPE V5 V w Q <br /> FIRE SPRINKLERS NO Z Z Z cz (V <br /> STORIES ONE I J 4 W N <br /> AREA 2240 5.F. (n I v �/ Z 111 <br /> !Y � <br /> I Q1 I ILv6 ~ v <br /> EXISTING BUILDINGS TO z [L 0k <br /> BE APPROVED: � � I Lu Lu <br /> o z w �_ o <br /> BUILDING #3 ~ 0 O O <br /> � tiJ <br /> BARREL, CASE STORAGE I I I <br /> OL0- <br /> OCCUPANCY 51 <br /> CONST. TYPE IIB �_ Q <br /> FIRE SPRINKLERS NO ,', <br /> m STAMP <br /> STORIES ONEIli = <br /> AREA 8,000 S.F. I Q 1 I O e P� �O,y�` <br /> BUILDING #5 I I 4U���� %�2 <br /> 5EVERA6E SERVICE (ROOF ONLY) ~ i z <br /> Q ` � <br /> OCCUPANCY M O �cL EXP. 3-3490 <br /> CONST. TYPE VB <br /> * <br /> FIRE SPRINKLERS NO I I I *sTgTF OF1 vC A\-FC��\P <br /> STORIES ONE <br /> AREA 324 S.F. ELECTRONICALLY SIGNED <br /> 07/29/2026 11:20:48 AM <br /> BUILDING #6 THRU #10 — — — — 1,380.0' — — — W. TURNER ROAD <br /> OUTSIDE SEATING (ROOF ONLY) - _ _ _ — - _ _ <br /> OCCUPANCY B <br /> Dwoww <br /> CONST. TYPE VB RM <br /> FIRE SPRINKLERS NO chec4< D <br /> STORIES ONE MS <br /> NORTH <br /> AREA 256 S.F. DATE <br /> 1/30/25 Q <br /> S 1 7r: FLAN SCALE <br /> As NOTED Lr) <br /> 1°=200'-O" .tee NO. N <br /> 2501'1 Lf) <br /> STMT <br /> O <br /> Q0 <br /> N <br /> O <br /> N <br /> I of 2 5FEET5 Ol <br /> N <br />
The URL can be used to link to this page
Your browser does not support the video tag.