REVISIONS <br /> 0 <br /> w <br /> P01 1 g PRELIM LAYOUT 08/25/26 0 <br /> N <br /> (E) POLE PRELIM LAYOUT 08 29 26 <br /> SYSTEM SPECIFICATIONS POI COORDINATES TO PG&E 20 / / _ <br /> 37.968829°, -121 .163670° MORMON 1102 AT 12 KV <br /> c� <br /> SYSTEM SIZE DC 2,620.85 kW <br /> DISTRIBUTION CIRCUIT } <br /> SYSTEM SIZE AC 2,000.00 kW o <br /> N56 U <br /> DC/AC RATIO 1 .31 p <br /> MODULE FIRST SOLAR POLE 0 <br /> MANUFACTURER <br /> MODULE MODEL FS-753OA-TR1 <br /> MODULE RATING 530 W <br /> RECLOSER UTILITY 52R COMM. LEGEND : <br /> TOTAL MODULE QTY 4,945 <br /> MODULES PER W <br /> OH MV SPAN 30, 3W <br /> STRING 5 TRANSFORMER M LLI <br /> TOTAL NO. OF 989 POLE 1 o <br /> STRINGS 0 Q <br /> w <br /> INVERTER MODEL CPS SCH350KTL-DO/US-800 POTENTIAL TRANSFORMER W <br /> � o <br /> UTILITY <br /> INVERTER RATING 350 kW 325 kW* METER w Q W a o o, <br /> INVERTER QTY 2 4 MO TII 0 w CURRENT TRANSFORMER O <br /> STEP-UP 800V WYE /12KV DELTA, 2200KVA PL N C D cn W Q r- 0 <br /> TRANSFORMER M1 z c� 10 <br /> * INVERTER OUTPUT POWER SHALL BE FACTORY-SET MCOV I o z � o Lo o <br /> WITH A MAXIMUM NET OUTPUT LIMIT OF 325KW. M2 0 CO M � a GROUND, GND w ^� <br /> D a_ � o- od- <br /> cy 'Amish, 0LnZ r0- w <br /> Q I � SURGE ARRESTOR ���� zQ �z <br /> UTILITY INFORMATION _ _PC_C UTILITY < a- 0 w Ld � z � <br /> CONNECTIONS AT TOP OF POLE 1 CUSTOMER o v 0 POLE FOR OVERHEAD LINE � z 0 <br /> UTILITY PG&E POLE Cl cn cn <br /> INTERCONNECT 12kV 0 52R RECLOSER <br /> VOLTAGE MCOV I o 0) 00 o <br /> U <br /> FUSE u 1 Q' <br /> CUSTOMER N < 0 '- <br /> RECLOSER t=5 59G 810 81U XXXXA, XPY L679 R-PACOTE 10 � C- BREAKER oJD <br /> ) O � o <br /> _ Y z <br /> Q J <br /> INVERTER 3 <br /> POLE C2 - N <br /> UTILITY ACCESSIBLE WITH LOCK N <br /> DISCONNECT MCOV I PROVISION AND VISIBLE BLADE INVERTERS <br /> AND RISER I INERTIA LINEBOSS OAE O DISCONNECTING SWITCH o <br /> z w <br /> OVERHEAD LINE w Q <br /> � z 2UG MV CABLE 30, 3W p w z o <br /> - - - - - ae cn 0 <br /> UNDERGROUND LINE w z w cn <br /> I cnwoQ <br /> (N) PV SWITCHGEAR #1 I COMMUNICATION LINE PROJECT <br /> 2000A, 800V, 3�, 4W, NEMA3R, <br /> INV-01 MAIN BREAKER W/ I O ANSI DEVICE NUMBER <br /> TYP. Boo(TYP. OF 06) METERING SECTION <br /> XFMR 1 I Q <br /> . . . AC 80OV/12kV TRANSFORMER <br /> BREAKER 350A, 3P 2200KVA I PV MODULE 0 0 <br /> /---\ �� I w/ FUSE/DISCONNECT <br /> j, __o 0 O—A I <br /> Z=6�, X R=7 <br /> FROM OTHER / I 0 0 <br /> SOURCE CIRCUITS I (� <br /> 350A, 3P <br /> 2000A, 3P FT � CURRENT WEAK I 0 N LO <br /> PLANT LIMITING LINE + - - J Q <br /> I� <br /> SCADA FROM ALL OTHER 0 0 <br /> s I <br /> INVERTERS 350A, 3P LOAD <br /> �0 GFP BREAK i 0 O� <br /> TO 120/240/480V AUX 40A, 3P I I NOTES : <br /> PANELS FOR I <br /> 1 <br /> SCADA, TELECOM, 1 . AC MV CIRCUITS SHALL BE INSTALLED AND INTERCONNECTED WITH 0 <br /> TRACKERS UTILITY, PER UTILITY SPECIFICATIONS. <br /> Lo <br /> 2. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE LATEST 0 0 0 <br /> AHJ APPROVED EDITION OF NATIONAL ELECTRIC CODE. U N <br /> 3. ALL DC AND AC EQUIPMENT, WHERE APPLICABLE, SHALL BE LISTED Lo <br /> AND LABELED PER RECOGNIZED ELECTRICAL TESTING LABORATORY 0 <br /> AND INSTALLED PER THE LISTING REQUIREMENTS, THE N U <br /> MANUFACTURER'S INSTRUCTIONS & IN ACCORDANCE WITH NEC. Q0 0 Z <br /> 4. RECLOSER CONTROL SETTINGS TO BE COORDINATED WITH UTILITY 0 Q Q O <br /> AND CONTRACTOR. U u� U <br /> 5. RELAY TO BE PROVIDED WITH 8-HOUR BATTERY BACK-UP. SHEET TITLE <br /> 6. UTILITY RIG, METER, WEATHER STATION AND ASSOCIATED <br /> COMMUNICATIONS EQUIPMENT TO BE PROVIDED WITH BATTERY <br /> BACK-UP PER UTILITY REQUIREMENTS. <br /> 7. ALL BREAKERS AND DISCONNECT SWITCHES ARE CLOSED UNDER <br /> NORMAL OPERATING CONDITIONS UNLESS OTHERWISE NOTED. SINGLE LINE <br /> 8. THIS DRAWING REPRESENTS A CONCEPTUAL INTERCONNECTION <br /> SCHEME. THE INTENT IS TO COMMUNICATE PROJECT SPECIFIC D AG RAM <br /> EQUIPMENT, SIZE AND NEGOTIATE THE INTERCONNECTION DETAILS <br /> WITH THE UTILITY. THIS DRAWING HAS NOT BEEN ISSUED FOR <br /> CONSTRUCTION PURPOSES. THE DEVELOPER OR CONTRACTOR IS <br /> RESPONSIBLE FOR ENSURING A SYSTEM DESIGN IS COMPLETE AND <br /> APPROVED BY AN APPROPRIATELY LICENSED ENGINEER PRIOR TO <br /> PROCUREMENT AND CONSTRUCTION. <br /> SCALE: AS SHOWN <br /> 9. INVERTERS ARE IEEE 1547 COMPLIANT AND UL 1741 SA LISTED <br /> DRAWN:LR <br /> DATE: 08/29/26 <br /> SINGLE ENE DIAGRAM— <br /> E_�o ; NOT FOR CONSTRUCTION FOR IA DISCUSSION ONLY . E 10 1 <br /> SHEET 2 OF 2 <br /> THIS DRAWING AND ITS CONTENTS ARE THE PROPERTY OF SEQUOIA ENGINEERING AND DESIGN ASSOCIATES AND MAY NOT BE USED OR REPRODUCED WITHOUT WRITTEN PERMISSION. <br />