Laserfiche WebLink
DATE 8/30/25 <br />DEPTH TO WATER TOTAL DEPTH D.T.W. D.T.W. TOTAL D.T.W. TOTAL D.T.W. TOTAL D.T.W. TOTAL D.T.W. TOTAL <br />UNIT LOCATION <br />T - 1 111'DRY DRY DRY DRY DRY DRY <br />T - 2 74'DRY DRY DRY DRY DRY DRY <br />T - 3 143'DRY DRY DRY DRY DRY DRY <br />D - 87 97'81 81 81 81 81 81 <br />D - 88A 48'37 37 37 37 37 37 <br />D - 88B 50'39 39 39 39 39 39 <br />D - 89 104'107 106 107 106 107 107 <br />Totalizer Meter 176,000 176,000 0 176,000 0 176,000 0 176,000 0 176,000 0 <br />D - 93/95 165'N/A* N/A * N/A * N/A * N/A * N/A * <br />Totalizer Meter 1,411,600 1,411,500 -100 1,411,500 0 1,411,500 0 1,411,500 0 1,411,500 0 <br />D- 93/95 <br />LYSIMETER N/A N/A N/A N/A N/A N/A <br />D - 01N 88'73 73 73 73 73 73 <br />Totalizer Meter 1,381,900 1,382,500 600 1,383,100 600 1,383,700 600 1,384,500 800 1,384,900 400 <br />D- 01N <br />LYSIMETER 80 79 79 79 79 80 <br />D- 01S 90'80 77 77 77 77 79 <br />Totalizer Meter 670,600 671,300 700 672,600 1,300 673,500 900 674,600 1,100 675,500 900 <br />D- 01S <br />LYSIMETER 88 88 87 89 87 88 <br />D -02 84'80 79 79 79 80 78 <br />Totalizer Meter 2,550,400 2,552,700 2,300 2,557,400 4,700 2,560,800 3,400 2,564,900 4,100 2,564,900 0 <br />D- 02 <br />LYSIMETER 90 90 88 90 89 89 <br />F- NORTH POND 92'57 57 57 57 57 57 <br />Totalizer Meter 68,300 68,300 0 68,300 0 68,300 0 68,300 0 68,300 0 <br />TOTAL 3,500 6,600 4,900 6,000 1,300 <br />NOTES- AMOUNT PURGED IS CALCULATED USING TOTALIZER METER READINGS. ANY DEFICIENCIES OBSERVED WILL BE <br />NOTED AND REPORTED TO REPUBLIC. <br />?? <br />ANY DEFICIENCIES OBSERVED?NO NO NO NO NO <br />68' <br />ANY DEFICIENCIES OBSERVED?NO NO NO <br />NO <br />70' <br />ANY DEFICIENCIES OBSERVED?NO NO NO NO NO <br />NO NO <br />69' <br />ANY DEFICIENCIES OBSERVED?NO NO NO NO <br />NO <br />76' <br />ANY DEFICIENCIES OBSERVED? <br />* UNABLE TO REACH TOP OF <br />RISER.* UNABLE TO REACH TOP OF <br />RISER. <br />* UNABLE TO REACH TOP OF <br />RISER. <br />* UNABLE TO REACH TOP OF <br />RISER. <br />* UNABLE TO REACH TOP OF <br />RISER. <br />78' <br />ANY DEFICIENCIES OBSERVED?NO NO NO NO <br />NO <br />33' <br />ANY DEFICIENCIES OBSERVED?NO NO NO NO NO <br />34' <br />ANY DEFICIENCIES OBSERVED?NO NO NO NO <br />NO <br />35' <br />ANY DEFICIENCIES OBSERVED?NO NO NO NO NO <br />N/A <br />ANY DEFICIENCIES OBSERVED?NO NO NO NO <br />NO NO NO <br />N/A <br />ANY DEFICIENCIES OBSERVED?NO NO NO NO NO <br />SUMP <br />THRESHOLDS <br />N/A <br />ANY DEFICIENCIES OBSERVED?NO NO <br /> DEL-TECH GEOTECHNICAL SUPPORT, INC. <br />FORWARD LANDFILL <br />SUMP FIELD SUMMARY LOG 2025 <br />9/3/25 9/11/25 9/17/25 9/24/25 9/30/25