My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2026
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOCKEFORD
>
205
>
2300 - Underground Storage Tank Program
>
PR0232257
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2026 8:35:12 AM
Creation date
1/2/2026 10:32:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0232257
PE
2361 - UST FACILITY
FACILITY_ID
FA0000670
FACILITY_NAME
QUIK STOP MARKET #148
STREET_NUMBER
205
Direction
W
STREET_NAME
LOCKEFORD
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04116115
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
205 W LOCKEFORD ST LODI 95240
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SPECIFICATIONS <br /> ;, {.• r <br /> CAPABILITIES <br /> a�rih.rrtt•iii�Ynrnim AccuChart 3.0 Tank Calibration — utilizes enhanced geometric tank <br /> 333545 007 TLS•45f1PLUS application software chart modeling for the TLS-450PLUS with optional restricted calibration <br /> �.•aala,Rr�t t' — range to perform calibration. Chart volumes are calculated using <br /> 860091.301 TLS 450PLUStouch screen console with printer adjustable geometry parameters: diameter, capacity, end shape,tilt and <br /> 860091.401 TLS-450PLUS touch screen console without printer probe offset. <br /> 860091-061 TL'S-450PLUS console without display,without printer <br /> t,`,-tilt�ert�r;'�1Yit?+hlt�y <br /> Business Inventory Reconciliation (BIR) -- improves business <br /> decisions by combining meter transaction sales with AccuChart 3.0 Tank <br /> 332813-001 Universal Input/ output i interface module Calibration to better understand the site variance. It includes automated <br /> 332813-001 Universal Input/output interface module <br /> $33564-001 10-amp-controlier module reporting on: throughput thresholds, delivery thresholds, Capacity <br /> - thresholds, custom thresholds. <br /> i�i7io�iil�!raTt•)�1=�Lri�lilr:#.� <br /> 332818-001 SRefex interface module . Digital Pressurized Line Leak Detection (DPLLD) — provides <br /> 332866-001 Single RS-232 interface module advanced line leak detection to meet the capacity of growing fuel sites, <br /> 332868-001 RS 232 dual inteifiace module now certified up to 1,178 gallons of capacity. The DPLLD equipment <br /> 332870.001 RS-232/RS-485 dual interface module performs a 3.0 gph line leak test following each dispense. With the <br /> proper software enhancement feature installed, the DPLLD equipment <br /> 332972.006 Continuous Statistical Leak Detection(CSLD) will also perform 0.2 and/or 0.1 gph line tests to meet your regulatory <br /> 332972-007 Ultimate Testing Line Leak Detection for DPLLD needs, eliminating the need for separate annual line leak testing, <br /> '332972-008 Risk Management Line Leak Detection for DPLLD Built-in Data Logging — enables approved data transfer for wet stock <br /> 332972-009 Base Compliance Line Leak Detection for DPLLD management. <br /> 332972-018 Timed Sudden Loss Detection <br /> 333149.001 BIR/AccuChart TLS-45OPWS EDIM factory installed Timed Sudden Loss Detection — monitors unexpected changes in <br /> 333580-061 BIR/ACcuChart TLS-45OPWS CDIM factory Installed inventory, exposing possible issues including theft during <br /> 333581-001 BIR/AccuChart TLS-450PLUS LVDIM factory installed quiet periods. <br /> 333582-001 BIR/AccuChart TLS-45oPLUS MDIM factory installed Diesel Exhaust Fluid (DEF) Recirculation — provides a recirculation and/ <br /> + Includes a 2-port RS-232 Module,a 3-port Ethernet Module and a 2-port USB Module. or Temp Control heat trace system to prevent DEF product from freezing <br /> or overheating in lines that utilize DEF in bulk dispensing systems. <br /> Intelligent Pump Control (IPC) — allows the TLS-450PLUS to display <br /> and report Submersible Turbine Pump (STP) activity through a direct <br /> communication link between a STP pump controller and the <br /> TLS-450PLUS system via a RS-485 connection. This software feature <br /> is available only in the TLS-450PLUS platform. <br /> lot <br /> The TLS-450PLUS ATG and STP control boxes act <br /> as the interface between the STP and the dispenser, <br /> while numerous sensors and probes monitor various- = <br /> L-_- <br /> conditions to ensure the fueling system remains <br /> healthy. If an abnormal state is detected, the <br /> TLS-450PLUS ATG will record a condition result and <br /> generate an audible and visual alarm to notify the <br /> store operator. Remote connectivity options for the <br /> TLS-450PLUS ATG ensure that critical site statuses, ; <br /> such as inventory and alarm activity are available i <br /> to site managers when they are not onsite. Stay <br /> connected, secure, and compliant with Veeder-Root's � <br /> Integrated Site Solutions. <br /> 6 � $ <br />