My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2026
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6633
>
2300 - Underground Storage Tank Program
>
PR0231784
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/23/2026 9:14:12 AM
Creation date
1/6/2026 3:31:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0231784
PE
2361 - UST FACILITY
FACILITY_ID
FA0003834
FACILITY_NAME
H & S ENERGY PRODUCTS LLC #3081
STREET_NUMBER
6633
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
09741048
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
6633 PACIFIC AVE STOCKTON 95207
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CP26 - UST FULL Inspection Report <br />Date: <br />January 20, 2026 <br />Facility Address: <br />6633 PACIFIC AVE, STOCKTONH & S ENERGY PRODUCTS LLC #3081 <br />Facility Name: <br />Environmental Health Department <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item #Remarks <br />5 23 CCR 16 2613(a)(6) and (b), 2650(a), (d), and (e) 2011013 - Facility has submitted a complete and accurate UST <br />Response Plan <br />OBSERVATION: Owner/Operator failed to submit a complete and accurate UST Response Plan. <br />- The emergency contact information of persons responsible were missing. <br />CORRECTIVE ACTION: Submit a complete and accurate UST Response Plan into CERS. <br />This is a (Minor) Violation. <br />40 23 CCR 16 2613(e) 2011002 - Installation, repair, lining, integrity, calibration, and release records maintained for life of <br />UST <br />OBSERVATION: Records of installation, repairs, linings, intregrity certification, tank calibration charts, and/or <br />unauthorized release reports were not kept onsite, or offsite if approved by the UPA, for the life of the UST. <br />CORRECTIVE ACTION: Immediately locate and maintain these records onsite and submit copies to the UPA within 30 <br />days. <br />This is a (Minor) Violation. <br />44 23 CCR 16 2643(c) and (d); HSC 6.7 25288 2031031 - Facility has corrected all previously cited violations <br />OBSERVATION: An inspection was last done on 1/23/25 and an inspection report was issued identifying information to <br />be submitted to bring this site into compliance. This information was required to be submitted by 2/22/25. This <br />information has not been received resulting in a non-compliant status for this facility. <br />- Open Violation 2030073: An inspection was last done on 1/30/2024 and an inspection report was issued identifying <br />information to be submitted to bring this site into compliance. This information was required to be submitted by <br />2/29/2024. This information was received on 3/6/2024, 6 days late. <br />CORRECTIVE ACTION: Ensure that a written response documenting corrective actions taken or proposed is submitted <br />within 30 days of receiving an inspection report. <br />This is a (Class II) Violation. <br />Inspector Phone: <br />(209) 616-3031 <br />Inspector: <br />Allen Asio, REHS <br />Date: 1/20/2026 <br />Printed Name and Title: <br />Christian Torres, Environmental <br />Compliance Manager <br />Received by: <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING THIS <br />FACILITY BACK INTO COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Overall Inspection Comments <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting paperwork, <br />by February 19, 2026. <br />This report was reviewed with Pablo Ibarra, Manager, and Anthony Reyes, Technician, on the day of inspection. <br />To minimize person to person contact EHD is choosing to write the name of person receiving the report instead of <br />having them sign. Starting July 1, 2025, all in-office CERS help will be provided at EHD hourly rate ($179). To <br />schedule an appointment, please call (209) 468-3420. <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD <br />Page 4 of 4EHD - CUPA Inspection Report IS03 <br />CP26 - UST FULL <br />1/20/2026FA0003834 PR0231784 4601847
The URL can be used to link to this page
Your browser does not support the video tag.