My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2026
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOWELL
>
1975
>
2300 - Underground Storage Tank Program
>
PR0232521
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2026 12:36:30 PM
Creation date
1/6/2026 3:32:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0232521
PE
2361 - UST FACILITY
FACILITY_ID
FA0004044
FACILITY_NAME
TUSD BUSINESS SERVICES
STREET_NUMBER
1975
Direction
W
STREET_NAME
LOWELL
STREET_TYPE
AVE
City
TRACY
Zip
95376
APN
23213008
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1975 W LOWELL AVE TRACY 95376
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Release Detection Equipment Testing Report Form <br /> 7. LINE LEAK DETECTOR TEST RESULTS <br /> ❑Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) <br /> ❑ Check this box if Appendix 5.2 continuation page is attached. <br /> Simulated release rate verified: (Check all that apply.) Yes No NA <br /> 1713 GPH ❑0.1 GPH (Required only if LLD performs line tightness testing) <br /> Has the testing equipment been properly calibrated? p ❑ ❑ <br /> For emergency tank systems, does the LLD create an audible and visual alarm ❑ ❑ 0 <br /> when a release is detected? <br /> For mechanical LLDs, does the LLD restrict the flow through the pipe when a 0 ❑ ❑ <br /> release is detected? <br /> For electronic LLDs, does the pressure supply pump automatically shut off when ❑ ❑ 0 <br /> a release is detected? <br /> For electronic LLDs, does the pressure supply pump automatically shut off if the ❑ ❑ 0 <br /> monitoring system or LLD is disabled or disconnected? <br /> For electronic LLDs, does the pressure supply pump automatically shut off if the ❑ ❑ 0 <br /> monitoring system or LLD malfunctions or fails a tightness test? <br /> For electronic LLDs, have all accessible wiring connections been visually ❑ ❑ 0 <br /> inspected for kinks and breaks? <br /> Were all items on the equipment manufacturer's maintenance checklist 0 ❑ ❑ <br /> completed? <br /> Were all LLDs confirmed operational within regulatory requirements? p ❑ ❑ <br /> List only line leak detectors tested. <br /> LLD ID LLD Model Lines Monitored Pass Fail <br /> 87 99 LD 2000 87 0 ❑ <br /> ❑ ❑ <br /> DIESEL RJ - FX 1 DV DIESEL 0 ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> Describe all answers marked "No"or "Fail"and the proposed remedy in Section 8. <br /> List all equipment either replaced or repaired (including cleaning or adjustment) in Section 8. <br /> Page 4 of 6 <br />