Laserfiche WebLink
SAN aOAQUIN AMENDED Environmental Health Department <br /> —COUNTY— 1�2 U�2026 <br /> „realness grows here. <br /> CP26 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> VAN DE POL ENTERPRISES INC 1816 E FRONTAGE RD RIPON JanuarV 14 2026 <br /> 30 23 CCR 16 2613(c)(3), 2633, 2640(e), 2642(k), 2660(c) and (e), 2664; HSC 6.7 25284.2 2031001 - Spill buckets meet <br /> requirements, have been tested as required, and records kept for 36 mths (TCR 9a) <br /> OBSERVATION: Owner/Operator failed to meet one or more of the following spill container requirements: install or <br /> maintain spill container which is liquid-tight; has a minimum capacity of five gallons; has a functional drain valve or other <br /> method for the removal of liquid from the spill container; is protected from galvanic corrosion; performed tightness test at <br /> installation, every 12 months thereafter, and within 30 days after a repair; tested to confirm liquid capacity is no less than <br /> five gallons; tested by a certified UST service technician; maintain testing records for 36 months. <br /> -The Spill Container test for 2025 was 1 month late in February 2025. <br /> CORRECTIVE ACTION: Install or repair spill buckets to meet all of the listed requirements, have tightness tested using <br /> approved method, by certified UST service technician, and submit documentation to verify compliance. Maintain all <br /> testing records for 36 months. <br /> This is a Repeat (Class 2)Violation. <br /> 34 23 CCR 16 2631(a), (f)-a) 2031017 - DO inspections completed at least every 30 days and meet all requirements (TCR <br /> 12) <br /> OBSERVATION: Facility did not comply with the following DO inspection requirement: <br /> -The 1/8/2026 DO Visual Inspection report indicated the incorrect due dates in Section 10. <br /> -The 12/10/2025 DO Visual Inspection report was not signed by the Owner in Section 6 <br /> CORRECTIVE ACTION: Ensure that facility is complying with all DO inspection requirements noted above. Submit copy <br /> of compliant DO inspection record. <br /> This is a Repeat (Class 2)Violation. <br /> 40 23 CCR 16 2613(e) 2011002 - Installation, repair, lining, integrity, calibration, and release records maintained for life of <br /> UST <br /> OBSERVATION: Records of installation, repairs, linings, integrity certification, tank calibration charts, and/or <br /> unauthorized release reports were not kept onsite, or offsite if approved by the UPA, for the life of the UST. <br /> - Installation records such as Installation test results, manufacturer checklists and manuals and as built drawings were <br /> not available at the time of inspection. <br /> CORRECTIVE ACTION: Immediately locate and maintain these records onsite and submit copies to the UPA within 30 <br /> days. <br /> This is a (Minor)Violation. <br /> EHD-CUPA Inspection Report IS03 Page 5 of 6 FA0003911 PR0231470 4599620 1/20/2026 <br /> CP26-U aST FULL g <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />