<br /> F. ALL MANUFACTURER REQUIRED TESTING, CORRECTIVE MEASURES, AND 12. MODIFY EXISTING FLOOR SURFACES AS REQUIRED TO INSTALL NEW
<br /> PREPARATIONS WITH REGARD TO THE EXISTING CONCRETE SLAB, FLOORING MATERIALS. THUS PREVENTING NOTICEABLE LUMPS AND/OR
<br /> GENERALNOTES INCLUDING PATCHED AREAS, SHALL BE INCLUDED AND PERFORMED. CONT. DEPRESSIONS. LEGEND
<br /> G. KEYNOTES ON THIS SHEET ONLY PERTAIN TO THIS SHEET 13. NOTIFY DESIGNER IN WRITING OF ANY DISCREPENCIES OR CONFLICTS IN
<br /> THE LOCATION OF NEW CONSTRUCTION. UPON COMPLETION OF WALL
<br /> A. ALL DIMENSIONS TO FACE OF STUD, U.N.O. H. ALL ITEMS NOT INDICATED TO BE REMOVED ARE EXISTING AND ARE TO 1. FIRE EXTINGUISHER#2 ARE 2A:10BC AND NO TO EXCEED 46" MOUNTING LAYOUT NOTIFY DESIGNER AND TENANT.
<br /> B. TYP. INTERIOR WALL FINISH FOR STUD WALLS: 5/8"TYPE 'X' GYP. BD., WATER CFC 1006 14. ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL, SQUARE AND METAL
<br /> REMAIN - PROTECT FROM DAMAGE. HEIGHT. L STUDS ALL @ 16�� o.c. FOR PATCH AND
<br /> RESISTANT TYPE IN RESTROOMS WHERE LOCATED WITHIN 2'-0" OF THE I. DEMOLITION ITEMS INDICATED ON THE PLANS DESCRIBE A SPECIFIC ITEM 2. ALL EQUIPMENT SHALL MEET ANSI AND NSF EQUIVILANT STANDARDS TRUE. INFILL SEE 4/ W 18/A8.2 AND 20/
<br /> FRONT AND/OR SIDES OF PLUMBING FIXT. GYP. BD. APPLICATION SHALL AND DO NOT CONSTITUTE THE COMPLETE EXTENT OF DEMOLITION FZ==F— WINDOW ASSEMBLY, SEE SCHEDULE ON A7
<br /> COMPLY w/CBC SECTION 2508. GYP. BD. SHALL BE FASTENED TO SUPPORTS REQUIRED FOR THE PROPOSED IMPROVEMENTS. CONTRACTOR SHALL 3. FLOOR SINK BELOW 3 COMPARTMENT SINK 15. PROVIDE A MAXIMUM OCCUPANT LOAD SIGN FOR DINING PURPOSES IN A
<br /> w/SCREWS. PERFORM ALL DEMOLITION REQUIRED FOR THE INSTALLATION OF NEW CONSPICUOUS LOCATION THAT REFLECTS 40 PERSONS, REF. 2016
<br /> IMPROVEMENTS. DEMOLITION TO BE COORDINATED IN FIELD WITH 4. REFRIGERATION UNITS IN WHICH POTENTIALLY HAZARDOUS FOODS ARE TO CBC, Sect. 1004.1. —17 DOOR AND FRAME, SEE SCHEDULE ON A7
<br /> C. DIMENSIONS WITH "MIN.","CLR.", OR"ABSOLUTE" IS MEASURED FROM FACE MECHANICAL DRAWINGS, PLUMBING DRAWINGS, ELECTRICAL DRAWINGS, BE STORED MUST BE CAPABLE OF MAINTAINING THE FOOD AT 41 F OR
<br /> OF WALL FINISH. FIRE ALARM DRAWINGS, ETC. AND ASSOCIATED TRADES. BELOW. 16. ALL STEAM TABLES, ICE MACHINES, & BINS, FOOD PREPARATION BINS,
<br /> (V
<br /> UTENSIL, WASHING SINKS, DISPLAY CASES, &OTHER SIMILAR EQUIPMENT
<br /> D. CONTRACTOR SHALL PATCH, REPAIR OR REPLACE ANY ADJACENT WORK 1. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION REGARDING 5. FLOOR SINKS ARE TO BE FLUSH TO FLOOR FINISH, EASILY ACCESSIBLE FOR THAT DISCHARGES LIQUID WASTE SHALL BE DRAINED BY MEANS OF INDIRECT
<br /> (WALL, CEILING, FLOOR SURFACES, ETC.)THAT IS DAMAGED, REMOVED SELECTIVE DEMOLITION REQUIREMENTS. INSPECTION AND CLEANING. WASTE PIPES &ALL WASTE DRAINED BY THEM SHALL DISCHARGE THROUGH A
<br /> AND/OR DEMOLISHED DURING THE COURSE OF CONSTRUCTION. SEE 2"AIR GAP INTO AN OPEN FLOOR SINK THAT IS PROPERLY CONNECTED TO T ACCESSIBLE MANEUVERING
<br /> SPECIFICATION REQUIREMENTS FOR CUTTING & PATCHING. 2. COORDINATE WITH RESPECTIVE TRADES FOR THE EXTENT OF 6. BACKFLOW DEVICES ARE TO BE INSTALLED ON THE FOLLOWING, (ALL HOSE HE DRAINAGE SYSTEM. CLEARANCE AT DOORS
<br /> DEMOLITION REQUIRED TO PROPERLY INSTALL PROPOSED
<br /> BIBBS, DISHWASHER, ACID-TYPE JUICE/SODA MACHINE w/COPPER TUBING OF L J it
<br /> it
<br /> E. ALL WORK WITHIN OR ON EXISTING WALLS SHALL BE PATCHED TO MATCH IMPROVEMENTS. THE JANITOR BASIN. 17. EXTERIOR DOORS EXISTING. 00
<br /> THE ADJACENT EXISTING CONDITIONS, INCLUDING BUT NOT LIMITED TO ALL LLJ
<br /> DEMOLITION REQUIRED TO PROPERLY INSTALL PROPOSED IMPROVEMENTS J. ALL EXISTING FLOOR FINISH ADHESIVES SHALL BE REMOVED WITH 7. THE EXHUAST FAN MUST BE INTERLOCKED WITH THE MAKE UP AIR UNIT. 18. THE MAIN EXTERIOR DOOR ARE PERMITTED TO BE EQUIPPED WITH KEY >F.E. WALL MOUNTED FIRE EXTINGUISHER EE
<br /> (STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, ETC.). FLOORING FINISH. OPERATED STATING "THIS DOOR TO REMAIN UNLOCKED WHEN THE BUILDING o I
<br /> 8. LIGHT FIXTURES LOCATED IN THE FOOD PREPARATION, UTENSIL WASH AND IS OCCUPIED SHALL BE IN LETTERS 1" HIGH ON A CONTRASTING MIN. RATING ED -B:C w
<br /> a. COORDINATE WITH RESPECTIVE TRADES FOR THE EXTENT OF K. ALL EXISTING UTILITY ITEMS THAT ARE NOT TO BE RE-USED ARE TO BE OPEN FOOD CONTAINER STORAGE AREAS ARE TO BE EQUIPPED WITH BACKGROUND. MAX. 46° HEIGHT
<br /> DEMOLITION AND PATCHBACK REQUIRED TO PROPERLY INSTALL REMOVED (CONDUITS, RACEWAYS, DUCTWORK, PIPING, WIRING, ETC.). SHATTERPROOF PROTECTION. Lo
<br /> PROPOSED IMPROVEMENTS. COORDINATE WITH PROPOSED IMPROVEMENTS. 19. MOVEMENT OF APPLIANCES w/CASTERS SHALL BE LIMITED BY A RESTRAINING N
<br /> 9. GENERAL CONTRACTOR SHALL CONFIRM LAYOUT FOR ELECTRICAL POWER DEVICE INSTALLED IN ACCORDANCE WITH THE CONNECTOR AND THE . . . . . . PATH OF TRAVEL Lu o
<br /> F. ALL NEW AND EXISTING FLOOR SUBSTRATES ARE TO BE CLEANED, L. EVERY DOORWAY WHICH IS LOCATED WITHIN AN ACCESSIBLE PATH OF APPLIANCE MANUFACTURERS INSTALLATION INSTRUCTIONS. o
<br /> PATCHED, REPAIRED, LEVELED, AND PREPARED AS REQUIRED BY FLOORING TRAVEL SHALL BE OF A SIZE AS TO PERMIT THE INSTALLATION OF A DOOR 10. GENERAL CONTRACTOR SHALL CONFIRM w/TENANT ALL REQUIRMENTS
<br /> FINISH MANUFACTURER RECOMMENDATIONS FOR FLOORING FINISH NOT LESS THAN TIN WIDTH AND NOT LESS THAN 6'-8" IN HEIGHT. WHEN REQUIRED FOR TELEPHONE, CPU, DATA LINES, PRIOR TO START OF 20. THE MAXIMUM UNLATCHING FORCE SHALL NOT EXCEED 15 POUNDS (67N).
<br /> SYSTEM SCHEDULED. INSTALLED, EXIT DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 CONSTRUCTION. Y
<br /> DEGREES AND SHALL BE SO MOUNTED THAT THE CLEAR WIDTH OF THE EXIT 21. DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES <
<br /> IS NOT LESS THAN 32", MEASURED BETWEEN THE FACE OF THE DOOR AND 11. ALL WALLS ARE DIMENSIONED FROM FINISH FACE OF SHEETROCK U.N.O. SHALL BE INSTALLED 34" MINIMUM &46 INCHES MAXIMUM ABOVE FINISH _ �
<br /> THE OPPOSITE STOP, [I I B-404.2.3 CBC] FLOOR.
<br /> 20'-0" ol
<br /> N
<br /> F
<br /> Z
<br /> Wz
<br /> O
<br /> m Z
<br /> 06 0
<br /> Z otS
<br /> 0-1 O �
<br /> W
<br /> Z
<br /> Q 0
<br /> U H
<br /> (29600 SF) N W
<br /> 0
<br /> EXISTING BUILDING a
<br /> N
<br /> #2405
<br /> 0
<br /> EXISTING APPARATUS
<br /> TRUCK PARKING
<br /> 0 0
<br /> zo
<br /> Lo Lo
<br /> Ail
<br /> � Z
<br /> O
<br /> 0
<br /> 0
<br /> Q
<br /> w
<br /> W
<br /> O
<br /> EXISTING COVERED o � LLJ Co
<br /> PATIO Q0 Z N zz
<br /> bo
<br /> J
<br /> GFI GFI GFI GFI GFI
<br /> Q U 2'-9" EXHAUST pOf GASSLL CC
<br /> o 0 VENT GRILL U- PROPOSED BUNK G = z
<br /> PROPOSED m _ LL
<br /> DOUBLE GAS FRIDGE HOUSE O
<br /> LOCKER ROOM p� —� °0 BURNER o � N O � o
<br /> GEN. BAR SINK 237 SF w (� w (n
<br /> U p
<br /> Q o 177 SF � c_
<br /> z O
<br /> O o z O
<br /> N
<br /> LL (�
<br /> CYn GFI GFI O GFI -'GFI GFI N r n Q /►
<br /> Lo
<br /> p 8'-2" 3'-0" 6'-6"
<br /> N PROJECT N0.
<br /> ti
<br /> 18'-0" 6'-0" 18'-0" 32'-6" 24'-0"
<br /> N � 5- 7
<br /> DRAWING
<br /> Q 98 -6 NORTH
<br /> 0
<br /> ° A2 . 1 d PROPOSED FLOOR PLAN 1/4" = 1�-o° 4