SAN aOAQUIN Environmental Health Department <br /> COUNTY— <br /> Greatness grows here. <br /> CP26 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ARCO STATION #826951* 1130 S WILSON WAY STOCKTON FebruarV 5 2026 <br /> 5 23 CCR 16 2613(a)(6) and (b), 2650(a), (d), and (e) 2011013 - Facility has submitted a complete and accurate UST <br /> Response Plan <br /> OBSERVATION: Owner/Operator failed to submit a complete and accurate UST Response Plan. <br /> - Response plan submitted in CERS does not contain phone number for responsible persons. <br /> CORRECTIVE ACTION: Submit a complete and accurate UST Response Plan. <br /> This is a Repeat (Class 2)Violation. <br /> 11 23 CCR 16 2613(c)(6), 2633, 2651(b)(1), 2660(c) and (e), 2663 2031009- Leak detection equipment tested by qualified <br /> service technician every 12 months (TCR 9d) <br /> OBSERVATION: Owner/Operator failed to have a properly qualified service technician test leak detection equipment <br /> every 12 months. <br /> -The leak detection equipment was last tested in January 2025, it was next tested in February 2026 which is one month <br /> late. <br /> CORRECTIVE ACTION: Have a properly qualified service technician test leak detection equipment every 12 months. <br /> This is a (Minor)Violation. <br /> 30 23 CCR 16 2613(c)(3), 2633, 2640(e), 2642(k), 2660(c) and (e), 2664; HSC 6.7 25284.2 2031001 - Spill buckets meet <br /> requirements, have been tested as required, and records kept for 36 mths (TCR 9a) <br /> OBSERVATION: Owner/Operator failed to meet one or more of the following spill container requirements: install or <br /> maintain spill container which is liquid-tight; has a minimum capacity of five gallons; has a functional drain valve or other <br /> method for the removal of liquid from the spill container; is protected from galvanic corrosion; performed tightness test at <br /> installation, every 12 months thereafter, and within 30 days after a repair; tested to confirm liquid capacity is no less than <br /> five gallons; tested by a certified UST service technician; maintain testing records for 36 months. <br /> -Spill container for 91 tank was leaking into the fill sump <br /> -Spill container testing was last done in January 2025, it was next done in February 2026 which is one month late. <br /> CORRECTIVE ACTION: Install or repair spill buckets to meet all of the listed requirements, have tightness tested using <br /> approved method, by certified UST service technician, and submit documentation to verify compliance. Maintain all <br /> testing records for 36 months. <br /> This is a Repeat (Class 2)Violation. <br /> EHD-CUPA Inspection Report IS03 Page 4 of 5 FA0003601 PR0231861 4608921 2/5/2026 <br /> CP26-UaST FULL g <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />