Laserfiche WebLink
CP26 - UST FULL Inspection Report <br />Date: <br />January 8, 2026 <br />Facility Address: <br />3633 DUCK CREEK DR, STOCKTONRYDER TRUCK RENTAL #1071 <br />Facility Name: <br />Environmental Health Department <br />15 23 CCR 16 2614, 2660(a)2011016 - UPA was notified in writing at least 72 hours prior to testing OUT R COS <br />16 23 CCR 16 2651(e) and <br />(f), 2652; HSC 6.7 <br />25290.1(d) and (e) <br />2031004 - Interstitial space of UST and piping are continuously monitored with <br />audible/visual alarm (TCR 9d) <br /> OUT R COS <br />17 23 CCR 16 2640(b)(1)- <br />(9); HSC 6.7 25291(a)(1- <br />6) and (b) <br />2061001 - Type 1 UST mon system can detect loss from primary, has continuity, <br />& primary product tight <br /> OUT R COS <br />18 23 CCR 16 2640(b)(1)- <br />(9), 2641(b); HSC 6.7 <br />25290.1(c), (d) and (e), <br />25290.2(c) and (d) <br />2061002 - Type 2/3 UST mon system can detect liq/vapor from primary, has <br />continuity, & primary product-tight <br /> OUT R COS <br />19 23 CCR 16 2651(c)(1) 2031006 - Leak detection equipment properly installed, calibrated, operated, and <br />maintained (TCR 9d) <br /> OUT R COS <br />20 23 CCR 16 2651(a) and <br />2652(a)(2) <br />2061003 - Leak detection equipment detects leak at the earliest possible <br />opportunity, LLD installed (TCR 9d) <br /> OUT R COS <br />21 HSC 6.7 25299(a)(9) 2031025 - Leak detection equipment has not been tampered with or disabled <br />(TCR 9d) <br /> OUT R COS <br />22 23 CCR 16 2652(a)(4) 2031012 - Type 1 & 2 UST piping out of UDC is fail-safe/shut down, UDC leak <br />shuts off pump/flow (TCR 9d) <br /> OUT R COS <br />23 23 CCR 16 2652(a)(2)2031013 - LLD on piping meets monitoring requirements, audio/visual alarm okay <br />for emergency tank (TCR 9d) <br /> OUT R COS <br />24 23 CCR 16 2613(c)(11), <br />2651(g) <br />2031007 - Visual monitoring of Type 1 UST complies with requirements including <br />maintaining records (TCR 9d) <br /> OUT R COS <br />25 23 CCR 16 2613, 2651(b) <br />(2) and (3), 2680 <br />2031008 - Alternative monitoring requirements have been met, including <br />maintaining record of results <br /> OUT R COS <br />26 23 CCR 16 2612(o); HSC <br />6.7 25281.5(b)(3) <br />2031019 - Emergency tank system unburied fuel piping visually inspected at least <br />monthly and log kept <br /> OUT R COS <br />27 23 CCR 16 2612(n); HSC <br />6.7 25281.5(b)(2) <br />2031022 - Unburied fuel piping at marinas visually inspected at least daily and log <br />kept <br /> OUT R COS <br />28 23 CCR 16 2663(b) 2031023 - Tag/sticker properly affixed to release detection equipment tested OUT R COS <br />29 23 CCR 16 2640(b); HSC <br />6.7 25290.1(c) and (e), <br />25290.2(c), 25291(a)(2) <br />2031015 - Secondary containment provided and properly maintained OUT R COS <br />30 23 CCR 16 2613(c)(3), <br />2633, 2640(e), 2642(k), <br />2660(c) and (e), 2664; <br />HSC 6.7 25284.2 <br />2031001 - Spill buckets meet requirements, have been tested as required, and <br />records kept for 36 mths (TCR 9a) <br /> OUT R COS <br />31 23 CCR 16 2613(c)(4), <br />2633, 2640(f), 2660(c) <br />and (e), 2665 <br />2031002 - Overfill prevention system meets overfill requirements, tested as <br />required, records kept (TCR 9b) <br /> OUT R COS <br />32 23 CCR 16 2613(c)(12) <br />and (d), 2640(c), 2661 <br />2031003 - Corrosion protection is installed/maintained as required, records <br />maintained properly (TCR 9c) <br /> OUT R COS <br />33 23 CCR 16 2613(c)(6), <br />2640(b)(10)(C) <br />2031014 - Safe Suction piping drains back into Type 1 UST, one check valve, <br />insp's performed/logged (TCR 9d) <br /> OUT R COS <br />34 23 CCR 16 2631(a), (f)-(j)2031017 - DO inspections completed at least every 30 days and meet all <br />requirements (TCR 12) <br /> OUT R COS <br />35 23 CCR 16 2613(c)(1), <br />2631(k) <br />2011005 - DO inspections and all attachements maintained onsite or offsite if <br />approved for 36 months (TCR 12) <br /> OUT R COS <br />36 23 CCR 16 2631(b) and <br />(c), and 2643(e) <br />2031018 - Initial and annual training provided to employees and at least one <br />trained employee is present <br /> OUT R COS <br />37 23 CCR 16 2613(c)(2), <br />2631(e) <br />2011006 - Copies of Facility Employee Training Certificates maintained on site or <br />readily available location <br /> OUT R COS <br />38 23 CCR 16 2613(c)(10) <br />and (13) <br />2011003 - Records of release detection monitoring and maintenance properly <br />maintained for 36 months (TCR 9d) <br /> OUT R COS <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD <br />Page 2 of 4EHD - CUPA Inspection Report IS03 <br />CP26 - UST FULL <br />1/9/2026FA0003758 PR0232461 4598165