My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2026
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1960
>
2300 - Underground Storage Tank Program
>
PR0232534
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2026 1:15:34 PM
Creation date
1/15/2026 7:53:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0232534
PE
2361 - UST FACILITY
FACILITY_ID
FA0004547
FACILITY_NAME
CHEVRON STATION #201383
STREET_NUMBER
1960
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23402001
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1960 W ELEVENTH ST TRACY 95376
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Release Detection Equipment Testing Report Form <br /> 7. LINE LEAK DETECTOR TEST RESULTS <br /> ❑ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) <br /> Check this box if Appendix 5.2 continuation page is attached. <br /> Simulated release rate verified: (Check all that apply.) Yes No NA <br /> Z 3 GPH ❑ 0.1 GPH 'Required only if LLD perfbnns fine tightness testin <br /> Has the testing equipment been properly calibrated? 0 ❑ ❑ <br /> For emergency tank systems, does the LLD create an audible and visual alarm ❑ ❑ <br /> when a release is detected? <br /> For mechanical LLDs, does the LLD restrict the flow through the pipe when a ❑ ❑ Z <br /> release is detected? <br /> For electronic LLDs, does the pressure supply pump automatically shut off when ❑ ❑ <br /> a release is detected? <br /> For electronic LLDs, does the pressure supply pump automatically shut off if the ❑ ❑ <br /> monitoring system or LLD is disabled or disconnected? <br /> For electronic LLDs, does the pressure supply pump automatically shut off if the LJ ❑ <br /> monitoring system or LLD malfunctions or fails a tightness test? <br /> For electronic LLDs, have all accessible wiring connections been visually z L2 ❑ <br /> inspected for kinks and breaks? <br /> Were all items on the equipment manufacturer's maintenance checklist 0 ❑ ❑ <br /> completed? <br /> Were all LLDs confirmed operational within regulatory requirements? ❑ ❑ ❑ <br /> List only lure leak detectors tested. <br /> LLD IO LLD Model Lines Monitored Pass Fail <br /> Q1 848480-001 SUP. PROD. LINE 7 ❑ <br /> Q2 848480-001 REG. PROD. LINE ❑ ❑ <br /> Q3 848480-001 DSL PROD. LINE 0 ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> Describe all answers marked 'No" or "Fail"and the proposed remedy in Section S. <br /> List ail equipment either replaced or repaired (including cleaning or adjustment) in Section B. <br /> Page 4 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.