EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1960
>
2300 - Underground Storage Tank Program
>
PR0232534
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2026 1:15:34 PM
Creation date
1/15/2026 7:53:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0232534
PE
2361 - UST FACILITY
FACILITY_ID
FA0004547
FACILITY_NAME
CHEVRON STATION #201383
STREET_NUMBER
1960
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23402001
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1960 W ELEVENTH ST TRACY 95376
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Spill Containment Testing Report Forth <br /> 6. SPILL CONTAINMENT DETAILS <br /> Test Method Developed by ❑ Manufacturer V Industry Standard ❑ Professional Engineer <br /> Test Type ❑ Pressure A Vacuum LA Hydrostatic <br /> Check this box if Appendix-6.1 continuation page is attached. <br /> Tank ID Regular Premium Diesel <br /> Spill Containment Manufacturer: OPW OPW OPW <br /> Method of Cathodic Protection 21 Nonmetallic Nonmetallic P1 Nonmetallic ❑ Nonmetallic <br /> ❑ Other ❑ Other ❑Other ❑ Other <br /> Is the spill containment 21 Yes 0 Yes 0Yes ❑ Yes <br /> minimum capacity five gallons <br /> excluding riser volume? ❑ N°* El No* El No* El No' <br /> Method to keep spill Drain 0 Drain Z Drain ❑ Drain <br /> containment empty ❑ pump ❑ Pump ❑ Pump ❑ Pump <br /> ❑ Other ❑ Other ❑Other ❑ Other <br /> Spill Containment Test Results Q Pass Z Pass ❑✓ Pass ❑ Pass <br /> ❑ Fail ❑ Fail ❑ Fail ❑ Fail <br /> Tank ID <br /> Spill Containment Manufacturer: <br /> Method of Cathodic Protection ❑ Nonmetallic ❑ Nonmetallic ❑ Nonmetallic ❑ Nonmetallic <br /> ❑ Other ❑ Other ❑Other ❑ Other <br /> Is the spill containment ❑ Yes ❑ Yes ❑Yes ❑ Yes <br /> minimum capacity five gallons <br /> excluding riser volume? [I No-' El No* El No* El No* <br /> Method to keep spill ❑ Drain ❑ Drain ❑ Drain ❑ Drain <br /> containment empty ❑ Pump ❑ Pump ❑ Pump ❑ Pump <br /> ❑Other ❑ Other ❑Other ❑ Other <br /> Spill Containment Test Results ❑ Pass ❑ Pass ❑ Pass ❑ Pass <br /> ❑ Fail ❑ Fail ❑ Fail ❑ Fail <br /> 7. COMMENTS <br /> * ❑ Check this box if any spill containment has less than 5 gallons capacity and requires <br /> replacement. <br /> Describe all answers marked `Other." ""No."or `'Fail" and each proposed remedy in Section T. <br /> Page 2 of 2 <br />