Laserfiche WebLink
SAN aOAQUIN Environmental Health Department <br /> COUNTY— <br /> Greatness grows here. <br /> CP26 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> 76 EXPRESS TIGER NO 1 15777 S FRENCH CAMP RD STOCKTON January 6 2026 <br /> 15 23 CCR 16 2614, 2660(a) 2011016-UPA was notified in writing at least 72 hours prior to testing ❑ OUT ❑ R ❑ COS <br /> 16 23 CCR 16 2651(e)and 2031004-Interstitial space of UST and piping are continuously monitored with ❑ OUT ❑ R ❑ COS <br /> (f),2652; HSC 6.7 audible/visual alarm (TCR 9d) <br /> 25290.1(d)and (e) <br /> 17 23 CCR 16 2640(b)(1)- 2061001 -Type 1 UST mon system can detect loss from primary, has continuity, ❑ OUT ❑ R ❑ COS <br /> (9); HSC 6.7 25291(a)(1- &primary product tight <br /> 6)and (b) <br /> 18 23 CCR 16 2640(b)(1)- 2061002-Type 2/3 UST mon system can detect liq/vapor from primary, has ❑ OUT ❑ R ❑ COS <br /> (9), 2641(b); HSC 6.7 continuity, &primary product-tight <br /> 25290.1(c), (d)and (e), <br /> 25290.2(c)and (d) <br /> 19 23 CCR 16 2651(c)(1) 2031006-Leak detection equipment properly installed, calibrated,operated, and ❑ OUT ❑ R ❑ COS <br /> maintained (TCR 9d) <br /> 20 23 CCR 16 2651(a)and 2061003-Leak detection equipment detects leak at the earliest possible ❑ OUT ❑ R ❑ COS <br /> 2652(a)(2) opportunity, LLD installed (TCR 9d) <br /> 21 HSC 6.7 25299(a)(9) 2031025-Leak detection equipment has not been tampered with or disabled ❑ OUT ❑ R ❑ COS <br /> (TCR 9d) <br /> 22 23 CCR 16 2652(a)(4) 2031012-Type 1 &2 UST piping out of UDC is fail-safe/shut down, UDC leak ❑ OUT ❑ R ❑ COS <br /> shuts off pump/flow(TCR 9d) <br /> 23 23 CCR 16 2652(a)(2) 2031013-LLD on piping meets monitoring requirements, audio/visual alarm okay ❑ OUT ❑ R ❑ COS <br /> for emergency tank(TCR 9d) <br /> 24 23 CCR 16 2613(c)(11), 2031007-Visual monitoring of Type 1 UST complies with requirements including ❑ OUT ❑ R ❑ COS <br /> 2651(g) maintaining records(TCR 9d) <br /> 25 23 CCR 16 2613, 2651(b) 2031008-Alternative monitoring requirements have been met, including ❑ OUT ❑ R ❑ COS <br /> (2)and (3), 2680 maintaining record of results <br /> 26 23 CCR 16 2612(o); HSC 2031019-Emergency tank system unburied fuel piping visually inspected at least ❑ OUT ❑ R ❑ COS <br /> 6.7 25281.5(b)(3) monthly and log kept <br /> 27 23 CCR 16 2612(n); HSC 2031022-Unburied fuel piping at marinas visually inspected at least daily and log ❑ OUT ❑ R ❑ COS <br /> 6.7 25281.5(b)(2) kept <br /> 28 23 CCR 16 2663(b) 2031023-Tag/sticker properly affixed to release detection equipment tested ❑ OUT ❑ R ❑ COS <br /> 29 23 CCR 16 2640(b); HSC 2031015-Secondary containment provided and properly maintained ❑ OUT ❑ R ❑ COS <br /> 6.7 25290.1(c)and (e), <br /> 25290.2(c), 25291(a)(2) <br /> 30 23 CCR 16 2613(c)(3), 2031001 -Spill buckets meet requirements, have been tested as required, and ❑ OUT ❑ R ❑ COS <br /> 2633,2640(e),2642(k), records kept for 36 mths(TCR 9a) <br /> 2660(c)and (e), 2664; <br /> HSC 6.7 25284.2 <br /> 31 23 CCR 16 2613(c)(4), 2031002-Overfill prevention system meets overfill requirements,tested as ❑ OUT ❑ R ❑ COS <br /> 2633,2640(f), 2660(c) required, records kept(TCR 9b) <br /> and (e), 2665 <br /> 32 23 CCR 16 2613(c)(12) 2031003-Corrosion protection is installed/maintained as required, records ❑ OUT ❑ R ❑ COS <br /> and (d), 2640(c), 2661 maintained properly(TCR 9c) <br /> 33 23 CCR 16 2613(c)(6), 2031014-Safe Suction piping drains back into Type 1 UST, one check valve, ❑ OUT ❑ R ❑ COS <br /> 2640(b)(10)(C) insp's performed/logged (TCR 9d) <br /> 34 23 CCR 16 2631(a), (f)-(j) 2031017-DO inspections completed at least every 30 days and meet all ■OUT ❑ R ❑ COS <br /> requirements(TCR 12) <br /> 35 23 CCR 16 2613(c)(1), 2011005-DO inspections and all attachements maintained onsite or offsite if ❑ OUT ❑ R ❑ COS <br /> 2631(k) approved for 36 months(TCR 12) <br /> 36 23 CCR 16 2631(b)and 2031018-Initial and annual training provided to employees and at least one ❑ OUT ❑ R ❑ COS <br /> (c), and 2643(e) trained employee is present <br /> 37 23 CCR 16 2613(c)(2), 2011006-Copies of Facility Employee Training Certificates maintained on site or ❑ OUT ❑ R ❑ COS <br /> 2631(e) readily available location <br /> 38 23 CCR 16 2613(c)(10) 2011003-Records of release detection monitoring and maintenance properly ❑ OUT ❑ R ❑ COS <br /> and (13) maintained for 36 months(TCR 9d) <br /> EHD-CUPA Inspection Report IS03 Page 2 of 4 FA0006977 PR0505746 4595966 1/6/2026 <br /> CP26-U aST FULL g <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />