Tank= 3 Grade=DSL <br /> Appendix A <br /> 71 SO Overfill Valve Upper Tube Calculation Worksheet <br /> Important: This is meant to be supplemental worksheet and not a substitute to following the installation <br /> manual instructions. All length measurements are in inches. Please contact the Authority Having Jurisdic- <br /> tion (AHJ)and review local,state,and national codes to determine the regulatory requirements governing <br /> shut-off capacity in your region,as well as take into account other considerations such as extreme tank tilt. <br /> Desired tank capacity for shut-off: SO%= 95% <br /> Dipstick Number on Tank Chart that corresponds to 100%volume(Y) = 118.375 <br /> Y <br /> Dipstick Number on Tank Chart that corresponds to SO% (X)_ — 106.875 N <br /> Upper Tube Reference Number Z=Y-X <br /> 11.5 (Z) <br /> — 2 <br /> Upper Tube Depth Inside Tank C=Z-2" <br /> Distance from top sealing surface for 71 SO Lip' to inside the <br /> top of Storage Tankz A=52.25 <br /> For Non-Testable 71 SO models only <br /> In all cases for non-testable 71 SO models,the top of the valve body must protrude at least 61/2" into the tank to <br /> provide a minimal clearance for proper operation.' Additionally the total Upper Tube Length must beat least 16" <br /> of length to include the protective bend in the tube. <br /> Is C less than 61/2" Yes/ No <br /> If NO,Upper Tube Length (D)=C+A Existing Upper Drop Tube Length= <br /> If YES,Upper Tube Length (D)=61/2"+A <br /> Pass /Fail = <br /> Upper Tube Length= <br /> For Testable 71 SO models only <br /> In all cases for Testable 71 SO models,the top of the valve body must protrude at least 61/2"into the tank to provide <br /> a minimal clearance for proper operation' Additionally the total Upper Tube Length must beat least 141/2"of <br /> length to include the protective bend in the tube. <br /> Is C less than 5" Yes/ No <br /> If NO,Upper Tube Length (D)=C+A- 1 1/2" Existing Upper Drop Tube Length = 65.75 <br /> If YES,Upper Tube Length (D)=61/2"+A- 1 1/2" <br /> Upper Tube Length= <br /> 60.25 Pass /Fail = PASS <br /> Sealing surface maybe the top of the Face Seal Adaptor,the built in sealing ledge inside some spill containers,or on non- <br /> vapor tight applications the top of the pipe nipple <br /> 7 Some Underground Storage tanks utilize a man way system at the top. Make sure to use the top of the storage tank for <br /> measurement and not to top of the man way. Consultyour underground tank manufacturer for height of the man way <br /> 3 This measurement is taken from the seam where the upper tube is attached to the valve body to the inside of the tank top. <br />