Laserfiche WebLink
A dOAQU1N Environmental Health Department <br /> COUNTY <br /> CP22 - HW SQG Inspection Report <br /> Facility Name: Facility Address: Date: <br /> STKN ARMYAVIATION SUPP FACILITY' 2000 STIMSON RD STOCKTON September 25 2025 <br /> 74 See below 3040-Release/Leaks/Spills-General ❑OUT ❑R ❑COS <br /> 75 3045-Release/Leaks/Spills-General Local Ordinance ❑OUT ❑R ❑COS <br /> 76 CA Health and Safety 3050-Abandonment/Illegal Disposal/Unauthorized Treatment-General ❑OUT ❑R ❑COS <br /> Code 25189.5(c) <br /> 77 3055-Abandonment/Illegal Disposal/Unauthorized Treatment-General Local Ordinance ❑OUT ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 29 CA Code of Regulations 66261.7 3030058-Empty containers>5 gallons properly managed. <br /> OBSERVATION: One 55 gallon green metal drum located in the boneyard was observed to be empty. <br /> REGULATION GUIDANCE: Empty containers which previously held a hazardous material, including hazardous waste <br /> must be managed per Title 22 California Code of Regulations(CCR)section 66261.7. Refer to this section and <br /> California Department of Toxic Substances Control guidance for more information. <br /> CORRECTIVE ACTION: Immediately label all empty containers with the date they were emptied and manage within <br /> one year of that date. Manage the container per Title 22 CCR section 66261.7. Provide a corrective action statement <br /> and supporting documentation to the San Joaquin County Environmental Health Department(EHD)within 30 days. <br /> This is(Minor)Violation. <br /> 51 CA Code of Regulations 66262.34(d)(2)3030034-Tests and maintains all required safety equipment at the facility. <br /> OBSERVATION:The following emergency equipment need to be maintained: <br /> - Fire extinguishers throughout the facility <br /> - Defibrillators are expired <br /> REGULATION GUIDANCE:All facility communications or alarm systems,fire protection equipment, spill control <br /> equipment, and decontamination equipment,where required, shall be tested and maintained as necessary to assure <br /> its proper operation in time of emergency. <br /> CORRECTIVE ACTION: Bring the fire extinguisher and defibrillators into proper working order by repair, replacement or <br /> testing. Provide a corrective action statement to the San Joaquin County Environmental Health Department within 30 <br /> days. <br /> This is (Class 2)Violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by 10/27/2025 . <br /> Wastes generated by this facility: <br /> -Contaminated rags <br /> -Waste oil <br /> - UW Aerosal cans <br /> -Contaminated dry sweep w/oil <br /> - Used oil cans <br /> FA0003648 PR0220060 SCO01 09/25/2025 <br /> EHD Rev.12/06/2021 Page 4 of 5 CP22-HW SQG OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />