My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2026
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
410
>
2300 - Underground Storage Tank Program
>
PR2500802
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/4/2026 9:28:28 AM
Creation date
1/26/2026 11:01:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR2500802
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0004939
FACILITY_NAME
MAVERIK - LATHROP #756
STREET_NUMBER
410
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
410 E LOUISE AVE LATHROP 95330
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Release Detection Equipment Testing Report Form <br /> 5. MONITORING SYSTEM AND PROGRAMMING <br /> A separate Release Detection Equipment Testing Report Form must be prepared for each <br /> monitoring system. <br /> Manufacturer of Monitoring Model of Monitoring System Software Version Installed <br /> System Control Panel Control Panel <br /> Veeder Root TLS-450+ 233.58 <br /> Attach the post-testing reports if the monitoring system is capable of generating Yes No NA <br /> either.- ❑✓ Monitoring System Set-up Report ❑✓ Alarm History Report <br /> Is all release detection equipment that was tested operational per manufacturer's ✓❑ ❑ <br /> specifications? <br /> Is the secondary containment free of damage, debris, or liquid? ✓❑ ❑ <br /> Are the release detection audible and visual alarms operational? ✓❑ ❑ <br /> Have all sensors been: 1) visually inspected for wiring kinks, breaks and residual ✓❑ ❑ ❑ <br /> buildup on floats; and 2) tested for functionality and confirmed operational? <br /> Are all sensors installed to detect a release at the earliest opportunity? ✓❑ ❑ ❑ <br /> Was the monitoring system set-up reviewed, and proper settings confirmed? ✓❑ ❑ ❑ <br /> Was the monitoring system's backup battery visually inspected, functionally tested, ✓❑ ❑ ❑ <br /> and confirmed operational? <br /> Was it confirmed that the flow of hazardous substance stops at the dispenser if a ✓❑ ❑ ❑ <br /> release is detected in the under-dispenser containment? <br /> Does the pressure supply pump automatically shut down if the piping secondary ✓❑ ❑ ❑ <br /> containment monitoring system fails to operate or is disconnected? <br /> Does the pressure supply pump automatically shut down if the piping secondary <br /> containment monitoring system detects a release? Which sensors initiate positive ✓❑ ❑ ❑ <br /> shut down? (Check all that apply) ❑✓ Containment Sump ❑✓ UDC <br /> If release detection alarms are relayed to a remote monitoring center, is all ✓❑ ❑ ❑ <br /> communication equipment operational? <br /> If there is any buried single-wall suction hazardous substance piping, was it <br /> confirmed using the inspection method approved by the Unified Program Agency, ❑ ❑ ❑✓ <br /> that the pipe contents drain back into the UST if the suction is released? <br /> Describe all answers marked "No"or "Fail"and the proposed remedy in Section 8. <br /> List all equipment either replaced or repaired (including cleaning or adjustment) in Section 8. <br /> Page 2 of 6 <br />