My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU-2601062
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
STATE ROUTE 99 E FRONTAGE
>
10088
>
2600 - Land Use Program
>
SU-2601062
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/5/2026 8:36:54 AM
Creation date
1/29/2026 8:08:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU-2601062
PE
2634 -ZONING COMPLIANCE REVIEW - MINOR (Z)
STREET_NUMBER
10088
Direction
N
STREET_NAME
STATE ROUTE 99 E FRONTAGE
STREET_TYPE
RD
City
STOCKTON
Zip
95212
APN
08607047
CURRENT_STATUS
Closed - Issued
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
10088 N STATE ROUTE 99 E FRONTAGE RD STOCKTON 95212
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
^a <br /> coFIRE F1 E <br /> M <br /> E E Storage I J I-LiY •� 4) <br /> ]� K I--I � (N) FE V <br /> T T Area SF Occ Type Load Factor TotaIOcc L — — — — — — — — — — -I L — — — — — — — - <br /> 1 1 I I ' � <br /> H H Storage r9 S1 500 A O <br /> I I V H <br /> U U <br /> Total SF r9-8 LU I <br /> 1 1 00 <br /> Total Occ Load � I N <br /> S � o� <br /> N C I O� r— <br /> Exits Required I C14� N <br /> N <br /> Lo <br /> Exits Provided 2 <br /> z � <br /> ' O <br /> 4 3-D Fire Extin uisher Sign I 1 i 00 <br /> A2.0 1" = 1'-0" 1 S1 - Storage 1 00 <br /> O U <br /> 1 2982 SF <br /> 1 O <br /> LU <br /> LL- <br /> 1 1 w <br /> z 1 1 z <br /> max. travel distance = 45-2" 1 � Drawn By Cm <br /> � � � � � � � � � � � � � ♦ ♦ � � � � 45' 2"<200 � � � � checker DEW <br /> characters & background of sign to be non- 1 <br /> glare finish and to contrast with each other. 1 Job# 160043 <br /> (standard color: white on blue background, <br /> Scale Noted <br /> unless approved otherwise) color & contrast of <br /> sign to be distinctly different than color & 1 Revision Schedule <br /> contrast of wall 1 I # Date Description <br /> 1 1 A 12/01/25 CYC1 -Zoning <br /> N11 / 1 1 Submittal <br /> MAXIMUM H 1 1 H <br /> Sign Placement 1 1 <br /> E OCCUPANCY <br /> 60" max. a.f.f. 1 1 <br /> 1 <br /> ' 1 <br /> 3/4" min. 100 PERSONS 48" min. a.f.f. <br /> � 1 <br /> I 1 <br /> sans-serif uppercase 1 <br /> characters, raised 1/32" per 1 1 <br /> 1 1" min. <br /> ANSI standards <br /> 1 1 <br /> Occupancy Si na e <br /> A2.0 1" = 1'-0" <br /> H _ (N) FE H <br /> characters & background of sign to be non-glare <br /> finish and to contrast with each other. <br /> (standard color:white on blue background, unless <br /> approved otherwise) color & contrast of sign to be provide 3-D fire extinguisher signage at 7-0" <br /> distinctly different than color& contrast of wall A.F.F. (See detail 4/A2.0) <br /> EX <br /> 1 Life Safety Plan <br /> Sign Placement A2.0 3/16" = V-0" <br /> �� 60" max. a.f.f. <br /> 5/8" min. to 2" max. R 0 U T E sans-serif uppercase characters, DOOR NOTES w <br /> raised 1/32" per ANSI standards Safety Legend 1) Thresholds at doorways shall not exceed 3/4 inch (19.1 mm) Q <br /> 3/8" min. to 1/2" in height above the finished floor or landing for sliding doors <br /> :2 <br /> serving dwelling units or 1/2 inch above the finished floor or U <br /> 48" min. a.f.f. landing for other doors. Raised thresholds and floor level 0 <br /> '•'�� filled quarter of circle Cumulative occupant load @ exit <br /> per 11 B 703.4.1 �j(X changes greater than 114 inch (6.4 mm) at doorways shall be V)3/8" min. represent faces of sign with"exit" ��// indicating direction of travel beveled with a slope not greater than one unit vertical in two ") <br /> corresponding grade II braille per illuminated units horizontal (50-percent slope). CBC 2022, Section 1010.1.7 Q <br /> ANSI standards 06 <br /> 2) Door finishes and hardware per door schedule. <br /> existing Emergency illumination Per CBC 1008.3 4111001 <br /> 3) Door handles, pulls, latches, locks and other operating <br /> (E The emergency power system shall provide backup power for the duration of at least 90 devices shall be installed 34 inches (864 mm) minimum and 44 �� <br /> 11 B-703.3.2 Position. inches maximum above the finished floor. Locks used only for <br /> Braille shall be positioned below the minutes and shall illuminate the path of travel at security <br /> y purposes and not used for normal operation are <br /> 5/8"min. to 2" max. EXIT Sign Placement corresponding text in a horizontal format, the rate of an average of 1 foot candle . floor permitted at any height. CBC 2022, 11 B-404.2.7 2132 N El Dorado St <br /> _ flush left or centered. If text is multi-lined, arrows shown indicate level. 2022 CBC, Sections 1008.1 thru 1008.3.5. <br /> 60" max. a.f.f. directional signage Stockton, CA 95204 <br /> 3/8"min. to 1/2' Braille shall be placed below the entire text. 4) All hardware at accessible doors shall comply w/CBC, (209) 227-7646 <br /> 48" min. a.f.f. Braille shall be separated 3/8 inch min. and sign includes Tactile exit sign.See detail2/A2.0 Chapter 10 and Title 24. <br /> •• • • 1/2 inch max. from any other tactile emergency egress illumination <br /> 3/8" min. per 1 1 B-703.4.1 characters and 3/8 inch min. from raised 5) Exit doors shall operate from the inside without the use of <br /> borders and decorative elements. Tactile exit route sign.See detail 2/A2.0 key or special effort per local code. RO SS/0 <br /> Travel distance 1 =X' thus <X' Max. Q� S q� <br /> 6) Maximum effort to operate doors shall not exceed 5 ,��'� C�� 9� �1-- <br /> Travel distance 2 =V thus < X' Max. CBC 2022, 1010.2.4 Locks and latches pounds for exterior doors, 5 pounds for interior doors, and not C 2m z <br /> 3 3.2. A readily visible durable sign is posted on the to exceed 15 Ibs at fire doors. CBC 1 1 B-404.2.9 w 76963 z m <br /> Common Path of Egress 1 = V thus<X' Max. egress side on or adjacent to the door stating: THIS 12 31 26 <br /> g 1 g: „ EXP. �L <br /> DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS 7) All doors equipped with single-effort, <br /> Common Path of Egress 2= Vthus<X' Max. OCCUPIED." The sign shall be in letters 1 inch (25 mm) non-grasp hardware (i.e., lever) shall be srI CIV11. <br /> T� Directional exit illuminated signage high on a contrasting background centered 34"to 44"above the finish floor or ground. CBC OF cPL%E <br /> 1 1 B-404.2.7 <br /> Illuminated exit signs- Provide an electrical system with storage These drawings and specifications are <br /> batteries to ensure continued illumination of one foot candle at 8) While the hardware schedule is intended to cover all doors the property and copyright ofJCwagner <br /> floor level for at least 1.5 hours in case of primary power loss. of the building, and to establish a type and standard of &Associates and shall not be used or <br /> (CBC 1008.3.4) quality, it shall be the responsibility of the hardware supplier duplicated in part or in whole on any <br /> to examine the plans and specifications, to furnish the proper other work except by agreement with <br /> Sign Placement Existing illuminated exit signs hardware for all Jcwagner&Associates. <br /> g �(E) openings whether listed or not. <br /> 5/8"min. to 2" max. 60" max. a.f.f. _ 9) If there are omissions in hardware groups, they shall be Life Safety <br /> 3/8"min. to 1/2" Fire extinguishers per requirements of NFPA. Field verify (E) <br /> 48" min. a.f.f. locations. Provide (N) 2A-10BC fire extinguisher (in cabinet if called to the attention of the Architect for clarification. Plan <br /> 3/8" rnin.s per 11 B-703.4.1 FE required) with maximum distance of 50'.Top of fire extinguisher 10) Key all internal doors alike with the same master key. <br /> not more than 3 to 5 AFF. Locations to be confirmed with the City <br /> — Coordinate levels of access with Owner and/or Tenants. <br /> m !2 Exit Route Sign of Stockton Fire Department/ Inspector. <br /> a \A2.0/ 1° = V-0° (N) Fire Extinguisher 1 1) Wall mounted door stops shall be provided where floor <br /> N \� (N) FE mounted stops would be hazardous or where deemed more <br /> practical. A200 <br /> N <br />
The URL can be used to link to this page
Your browser does not support the video tag.