PREPARED FOR: <br /> GENERAL CONSTRUCTION NOTES: ABBREVIATIONS: o <br /> 0 <br /> CN <br /> 1. PLANS ARE INTENDED TO BE DIAGRAMMATIC OUTLINE ONLY, UNLESS NOTED OTHERWISE. THE WORK SHALL INCLUDE FURNISHING A.B. ANCHOR BOLT FDN. FOUNDATION SCH. SCHEDULE b1c H <br /> MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE <br /> ABV. ABOVE F.O.C. FACE OF CONCRETE SHT. SHEET W r` <br /> DRAWINGS. ACCA ANTENNA CABLE COVER ASSEMBLY F.O.M. FACE OF MASONRY SIM. SIMILAR • r� � M <br /> 2. THE CONTRACTOR SHALL OBTAIN, IN WRITING, AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY ITEM NOT CLEARLY ADD'L ADDITIONAL F.O.S. FACE OF STUD SPEC. SPECIFICATIONS �--� o co <br /> DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS. A.F.F. ABOVE FINISHED FLOOR F.O.W. FACE OF WALL SQ. SQUARE v LL <br /> 3. CONTRACTOR SHALL CONTACT USA(UNDERGROUND SERVICE ALERT)AT (800)227-2600, FOR UTILITY LOCATIONS, 48 HOURS BEFORE A.F.G. ABOVE FINISHED GRADE F.S. FINISH SURFACE S.S. STAINLESS STEEL w z <br /> PROCEEDING WITH ANY EXCAVATION, SITE WORK OR CONSTRUCTION. ALUM. ALUMINUM FT.( ' ) FOOT (FEET) STD. STANDARD Ol__ <br /> 4. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS ALT. ALTERNATE FTG. FOOTING STL. STEEL 0 � <br /> UNLESS SPECIFICALLY INDICATED OTHERWISE, OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. ANT. ANTENNA G. GROWTH (CABINET) STRUC. STRUCTURAL V U Q <br /> 5. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CBC/ UBC'S REQUIREMENTS REGARDING EARTHQUAKE RESISTANCE, FOR, <br /> LL <br /> APPRX. APPROXIMATELY) GA. GAUGE TEMP. TEMPORARY 0 r--4 O <br /> ARCH. ARCHITECT(URAL) GI. GALVANIZE(D) THK. THICK(NESS) Y 0° <br /> BUT NOT LIMITED TO, PIPING, LIGHT FIXTURES, CEILING GRID, INTERIOR PARTITIONS, AND MECHANICAL EQUIPMENT. ALL WORK MUST AWG. AMERICAN WIRE GAUGE G.F.I. GROUND FAULT CIRCUIT T.N. TOE NAIL ^� Q <br /> COMPLY WITH LOCAL EARTHQUAKE CODES AND REGULATIONS. BLDG. BUILDING INTERRUPTER T.O.A. TOP OF ANTENNA W 0- <br /> CD <br /> 6. REPRESENTATIONS OF TRUE NORTH, OTHER THAN THOSE FOUND ON THE PLOT OF SURVEY DRAWINGS, SHALL NOT BE USED TO BILK. BLOCK GLB. (GLU-LAM) GLUE LAMINATED BEAM T.O.C. TOP OF CURB `-) <br /> IDENTIFY OR ESTABLISH BEARING OF TRUE NORTH AT THE SITE. THE CONTRACTOR SHALL RELY SOLELY ON THE PLOT OF SURVEY BLKG. BLOCKING GPS GLOBAL POSITIONING SYSTEM T.O.F. TOP OF FOUNDATION <br /> DRAWING AND ANY SURVEYOR'S MARKINGS AT THE SITE FOR THE ESTABLISHMENT OF TRUE NORTH, AND SHALL NOTIFY THE BM. BEAM GRND. GROUND T.O.P. TOP OF PLATE (PARAPET) <br /> ARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH THE WORK IF ANY DISCREPANCY IS FOUND BETWEEN THE VARIOUS ELEMENTS B.N. BOUNDARY NAILING HDR. HEADER T.O.S. TOP OF STEEL VENDOR: <br /> OF THE WORKING DRAWINGS AND THE TRUE NORTH ORIENTATION AS DEPICTED ON THE CIVIL SURVEY. THE CONTRACTOR SHALL BTCW. BARE TINNED COPPER WIRE HGR. HANGER T.O.W. TOP OF WALL <br /> ASSUME SOLE LIABILITY FOR ANY FAILURE TO NOTIFY THE ARCHITECT/ENGINEER. B.O.F. BOTTOM OF FOOTING HT. HEIGHT TYP. TYPICAL 0 <br /> 7. THE BUILDING DEPARTMENT ISSUING THE PERMITS SHALL BE NOTIFIED AT LEAST TWO WORKING DAYS PRIOR TO THE B/U BACK-UP CABINET ICGB. ISOLATED COPPER GROUND BUS U.G. UNDER GROUND <br /> ( " ) <br /> COMMENCEMENT OF WORK, OR AS OTHERWISE STIPULATED BY THE CODE ENFORCEMENT OFFICIAL HAVING JURISDICTION. CAB. CABINET IN. INCH(ES) U.L. UNDERWRITERS LABORATORYCANT. CANTILEVER(ED) INT. INTERIOR U.N.O. UNLESS NOTED OTHERWISE <br /> ID <br /> 8. DO NOT EXCAVATE OR DISTURB BEYOND THE PROPERTY LINES OR LEASE LINES, UNLESS OTHERWISE NOTED. C.I.P. CAST IN PLACE LB.(#) POUND(S) V.I.F. VERIFY IN FIELD P. MARSHALL &ASSOCIATES <br /> 9. ALL (E) UTILITIES, FACILITIES, CONDITIONS, AND THEIR DIMENSIONS SHOWN ON THE PLAN HAVE BEEN PLOTTED FROM AVAILABLE CLG. CEILING L.B. LAG BOLTS W WIDE (WIDTH) q= A CENTERLINE COMMUNICATIONS COMPANY <br /> RECORDS. THE ARCHITECT/ ENGINEER AND THE OWNER ASSUME NO RESPONSIBILITY WHATSOEVER AS TO THE SUFFICIENCY OR THE CLR. CLEAR L.F. LINEAR FEET (FOOT) W/ WITH 1000 HOLCOMB WOODS PKWY,SUITE 210 <br /> ACCURACY OF THE INFORMATION SHOWN ON THE PLANS, OR THE MANNER OF THEIR REMOVAL OR ADJUSTMENT. CONTRACTORS COL. COLUMN L. LONG(ITUDINAL) WD. WOOD ROSWELL,GA 30076 <br /> SHALL BE RESPONSIBLE FOR DETERMINING EXACT LOCATION OF ALL (E) UTILITIES AND FACILITIES PRIOR TO START OF <br /> CONC. CONCRETE MAS. MASONRY W.P. WEATHERPROOF OFFICE(678)280-2325 <br /> CONSTRUCTION. CONTRACTORS SHALL ALSO OBTAIN FROM EACH UTILITY COMPANY DETAILED INFORMATION RELATIVE TO WORKING CONN. CONNECTION(OR) MAX. MAXIMUM WT. WEIGHT <br /> SCHEDULES AND METHODS OF REMOVING OR ADJUSTING (E) UTILITIES. CONST. CONSTRUCTION M.B. MACHINE BOLT c CENTERLINE <br /> 10. CONTRACTOR SHALL VERIFY ALL (E) UTILITIES, BOTH HORIZONTAL AND VERTICALLY, PRIOR TO THE START OF CONSTRUCTION. ANY CONT. CONTINUOUS MECH. MECHANICAL P PLATE, PROPERTY LINE ISSUE STATUS:d PENNY (NAILS) MFR. MANUFACTURER <br /> DISCREPANCIES OR DOUBTS AS TO THE INTERPRETATION OF PLANS SHOULD BE IMMEDIATELY REPORTED TO THE ARCHITECT/ DBL. DOUBLE MIN. MINIMUM REV. DATE DESCRIPTION BY <br /> ENGINEER FOR RESOLUTION AND INSTRUCTION, AND NO FURTHER WORK SHALL BE PERFORMED UNTIL THE DISCREPANCY IS DEPT. DEPARTMENT MISC. MISCELLANEOUS A 06/10/25 90% ZONING FA <br /> CHECKED AND CORRECTED BY THE ARCHITECT/ ENGINEER. FAILURE TO SECURE SUCH INSTRUCTION MEANS CONTRACTOR WILL D.F. DOUGLAS FIR MTL. METAL 0 07/14/25 100% ZONING FA <br /> HAVE WORKED AT HIS/HER OWN RISK AND EXPENSE. DIA. DIAMETER (N) NEW 1 07/22/25 100% ZONING FA <br /> 11. ALL NEW AND (E) UTILITY STRUCTURES ON SITE AND IN AREAS TO BE DISTURBED BY CONSTRUCTION SHALL BE ADJUSTED TO FINISH DIAG. DIAGONAL NO.(#) NUMBER <br /> ELEVATIONS PRIOR TO FINAL INSPECTION OF WORK. DIM. DIMENSION N.T.S. NOT TO SCALE <br /> 12. ANY DRAIN AND/OR FIELD TILE ENCOUNTERED/ DISTURBED DURING CONSTRUCTION SHALL BE RETURNED TO IT'S ORIGINAL DWG. DRAWING(S) O.C. ON CENTER <br /> CONDITION PRIOR TO COMPLETION OF WORK. SIZE, LOCATION AND TYPE OF ANY UNDERGROUND UTILITIES OR IMPROVEMENTS SHALL DWL. DOWEL(S) OPNG. OPENINGEA. EACH P/C PRECAST CONCRETE <br /> BE ACCURATELY NOTED AND PLACED ON "AS-BUILT" DRAWINGS BY GENERAL CONTRACTOR, AND ISSUED TO THE ARCHITECT/ EL. ELEVATION PCs PERSONAL COMMUNICATION <br /> ENGINEER AT COMPLETION OF PROJECT. ELEC. ELECTRICAL SERVICES <br /> 13. ALL TEMPORARY EXCAVATIONS FOR THE INSTALLATION OF FOUNDATIONS, UTILITIES, ETC., SHALL BE PROPERLY LAID BACK OR ELEV. ELEVATOR PLY. PLYWOOD <br /> BRACED IN ACCORDANCE WITH CORRECT OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) REQUIREMENTS. EMT. ELECTRICAL METALLIC TUBING PPC POWER PROTECTION CABINET <br /> 14. INCLUDE MISC. ITEMS PER VERIZON WIRELESS SPECIFICATIONS E.N. EDGE NAIL PRC PRIMARY RADIO CABINET <br /> ENG. ENGINEER P.S.F. POUNDS PER SQUARE FOOT <br /> EQ. EQUAL P.S.I. POUNDS PER SQUARE INCH <br /> EXP. EXPANSION P.T. PRESSURE TREATED <br /> EXST.(E) (E) PWR. POWER (CABINET) LICENSOR: <br /> EXT. EXTERIOR QTY. QUANTITY <br /> APPLICABLE CODES, REGULATIONS AND STANDARDS: FAB. FABRICATION(OR) RAD.(R) RADIUS <br /> F.F. FINISH FLOOR REF. REFERENCE <br /> 1. SUBCONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES AS ADOPTED BY THE F.G. FINISH GRADE REINF. REINFORCEMENT(ING)FIN. FINISH(ED) REQ D/ REQUIRED <br /> LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION. FLR. FLOOR RGS. RIGID GALVANIZED STEEL <br /> 2. THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OF CONTRACT AWARD SHALL GOVERN <br /> THE DESIGN. <br /> 3. SUBCONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING STANDARDS: SYMBOLS LEGEND: <br /> 3.1. AMERICAN CONCRETE INSTITUTE (ACI) 318, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE <br /> 3.2. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), MANUAL OF STEEL CONSTRUCTION, ASD, NINTH EDITION IT IS A VIOLATION OF LAW FOR ANY <br /> GROUT OR PLASTER PERSONS, UNLESS THEY ARE <br /> 3.3. TELECOMMUNICATIONS INDUSTRY ASSOCIATION (TIA)222-G, STRUCTURAL STANDARD FOR STRUCTURAL ANTENNA TOWER ACTING UNDER THE DIRECTION <br /> AND ANTENNA SUPPORTING STRUCTURES A-3o0 A-3oo BLDG. SECTION (E) BRICK OF A LICENSED PROFESSIONAL <br /> 3.4. INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 81, GUIDE FOR MEASURING EARTH RESISTIVITY, GROUND ENGINEER, TO ALTER THIS <br /> IMPEDANCE, AND EARTH SURFACE POTENTIALS OF A GROUND SYSTEM IEEE 1100 (1999) RECOMMENDED PRACTICE FOR (E) MASONRY DOCUMENT <br /> POWERING AND GROUNDING OF ELECTRICAL EQUIPMENT. �A5 WALL SECTION CONCRETE <br /> A-310 PROJECT NAME: <br /> 3.5. IEEE C62.41, RECOMMENDED PRACTICES ON SURGE VOLTAGES IN LOW VOLTAGE AC POWER CIRCUITS (FOR LOCATION - = EARTH <br /> CATEGORY"CT'AND "HIGH SYSTEM EXPOSURE") <br /> 3.6. TIA 607 COMMERCIAL BUILDING GROUNDING AND BONDING REQUIREMENTS FOR TELECOMMUNICATIONS TELCORDIA GR-63 D5 DETAIL GRAVEL LV <br /> A-soo <br /> NETWORK PLYWOOD z Z <br /> 3.7. EQUIPMENT-BUILDING SYSTEM (NEBS): PHYSICAL PROTECTION Ci O O Lu <br /> ; <br /> 3.8. TELCORDIA GR-347 CENTRAL OFFICE POWER WIRING A-113 SAND Q <br /> 3.9. TELCORDIA GR-1275 GENERAL INSTALLATION REQUIREMENTS A4 C4 ELEVATION <br /> to <br /> 3.10. TELCORDIA GR-1503 COAXIAL CABLE CONNECTIONS A-113 A-113 PLYWOOD Z M <br /> Ln <br /> 3.11. ANY AND ALL OTHER LOCAL&STATE LAWS AND REGULATIONS A-113 SAND J <br /> 3.12. FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS REGARDING MATERIAL, METHODS OF = Q <br /> Q <br /> CONSTRUCTION, OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE SHALL GOVERN. WHERE THERE IS CONFLICT (E) STEEL (D V= ., <br /> BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL GOVERN. 001 DOOR SYMBOL MATCH LINE V Z <br /> = O <br /> �o WINDOW SYMBOL GROUND CONDUCTOR uj <br /> ~ a <br /> O � <br /> TILT-UP PANEL MARK OH OVERHEAD SERVICE CONDUCTORS cf) <br /> Tel TELEPHONE CONDUIT 00 <br /> PROPERTY LINE Ln <br /> — Pwr POWER CONDUIT NN <br /> CENTERLINE <br /> Coax COAXIAL CABLE <br /> ±0" ELEVATION DATUM CHAIN LINK FENCE <br /> AD GRID/COLUMN LINE WOOD FENCE <br /> SHEET TITLE: <br /> KEYNOTE, DIMENSION ITEM (P) ANTENNA GENERAL NOTES <br /> 3 (P) RRU LEGEND & <br /> 2 _ KEYNOTE, CONSTRUCTION ITEM (P) DC SURGE SUPPRESSION ABBREVIATIONS <br /> WALL TYPE MARK J (F) ANTENNA <br /> V VVV J <br /> (F) RRU <br /> OFFICE ROOM NAME Fol <br /> 101 I ROOM NUMBER E (E) EQUIPMENT T=2 <br />