My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
2112
>
2200 - Hazardous Waste Program
>
PR0538355
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/5/2026 9:54:11 AM
Creation date
2/5/2026 9:52:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0538355
PE
2229 - GEN 50<250 TONS PERMIT
FACILITY_ID
FA0022165
FACILITY_NAME
LATHROP WATER TREATMENT FACILITY / CORP YARD
STREET_NUMBER
2112
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
Lathrop
Zip
95330
APN
19816003
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\bmascaro
Supplemental fields
Site Address
2112 E Louise AVE Lathrop 95330
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Large Quantity Hazardous Waste Generator Program Inspection Report <br />Date: <br />December 08, 2025 <br />Facility Address: <br />2112 E Louise AVE, LathropLATHROP WATER TREATMENT FACILITY / COR <br />Facility Name: <br />Environmental Health Department <br />20 CA Code of Regulations <br />67100.7, 67100.8 <br />3010018 - LQG conducted a source reduction evaluation review and plan every <br />four years <br /> OUT R COS <br />21 CA Code of Regulations <br />67100.9 <br />3010019 - LQG prepared a Summary Progress Report using DTSC form #1262 <br />every four years <br /> OUT R COS <br />22 CA Health and Safety <br />Code 25244.19, <br />25244.21 <br />3010021 - LQG completed all source reduction evaluation review and plan <br />requirements <br /> OUT R COS <br />23 CA Health and Safety <br />Code 25163(a) <br />3050001 - Registered hazardous waste transporter used to transport hazardous <br />waste <br /> OUT R COS <br />24 CA Health and Safety <br />Code 25189.5(a) <br />3050002 - Disposed of hazardous waste at an authorized location OUT R COS <br />25 CA Health and Safety <br />Code 25187.6 <br />3040002 - Quarantined HW not removed, transferred, or disposed without <br />permission by authorized agent <br /> OUT R COS <br />26 CA Code of Regulations <br />66262.34(a) <br />3030012 - Disposed of hazardous waste within 90 days of accumulation start date OUT R COS <br />27 CA Code of Regulations <br />66262.34(e)(3) <br />3030057 - Met all requirements for hazardous waste satellite accumulation OUT R COS <br />28 CA Code of Regulations <br />66262.34(f) <br />3030007 - Labeled all containers or portable tanks containing hazardous waste OUT R COS <br />29 CA Code of Regulations <br />66265.171 <br />3030014 - Accumulated hazardous waste in containers that are in good condition OUT R COS <br />30 CA Code of Regulations <br />66265.172 <br />3030016 - Hazardous waste accumulated in lined and/or compatible containers OUT R COS <br />31 CA Code of Regulations <br />66265.173 <br />3030018 - Containers of hazardous waste closed except when adding or removing <br />waste <br /> OUT R COS <br />32 CA Code of Regulations <br />66265.174 <br />3030020 - Inspects all hazardous waste containers at least weekly OUT R COS <br />33 CA Code of Regulations <br />66265.176 <br />3030021 - Reactive and ignitable waste containers located at least 50 ft from <br />property line <br /> OUT R COS <br />34 CA Code of Regulations <br />66265.17(b), 66265.177 <br />3030023 - Incompatible waste in containers managed properly to prevent a reaction OUT R COS <br />35 CA Code of Regulations <br />66262.34(a)(1), <br />66265.178 <br />3030061 - Complied with air emission requirements for HW in containers OUT R COS <br />36 CA Code of Regulations <br />66261.7 <br />3030058 - Empty containers > 5 gallons properly managed OUT R COS <br />37 CA Code of Regulations <br />66262.34(f) <br />3030056 - Stationary tanks marked as "Hazardous Waste" and marked with <br />accumulation start date <br /> OUT R COS <br />38 CA Code of Regulations <br />66265.192(a) <br />3010025 - Obtained a written hazardous waste tank system assessment prior to <br />placing into use <br /> OUT R COS <br />39 CA Code of Regulations <br />66265.192(h) <br />3010032 - Written hazardous waste tank system assessment/reassessment by <br />P.E. completed <br /> OUT R COS <br />40 CA Code of Regulations <br />66265.192(k) <br />3010026 - Written hazardous waste tank system assessment meets all <br />requirements <br /> OUT R COS <br />41 CA Code of Regulations <br />66265.194 <br />3030026 - Tanks are compatible with hazardous waste and have spill/overflow <br />prevention provided <br /> OUT R COS <br />42 CA Code of Regulations <br />66265.193 <br />3030041 - Secondary containment provided and meets requirements for all <br />hazardous waste tank systems <br /> OUT R COS <br />43 CA Code of Regulations <br />66265.195 <br />3030029 - Conducts/documents daily inspections of hazardous waste tank system OUT R COS <br />44 CA Code of Regulations <br />66265.195(b-c) <br />3030042 - Inspect/document the HW tank system cathodic protection system <br />annually/impressed current bimonthly <br /> OUT R COS <br />45 CA Code of Regulations <br />66265.192(m) <br />3010027 - Obtained approval before replacement of identical/equivalent tank <br />system parts not in 66265.192(l) <br /> OUT R COS <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD <br />Page 2 of 4EHD - CUPA Inspection Report IS02 12/8/2025FA0022165 PR0538355 4585856
The URL can be used to link to this page
Your browser does not support the video tag.