Laserfiche WebLink
N' Pc°G S A N J O A Q U I N Environmental Health Department <br /> Q <br /> COUNTY <br /> cgtiFoa Greatness grows here. <br /> Photograph Log <br /> Site Name: Canary Renewables Corp Site Address: 809C Snedeker Ave. Stockton CA <br /> 95203 <br /> Record ID: PR0528724, PR0527608, PR0528437 Pro rams : HMBP, SQG HW, APSA <br /> Photo ra hers : Lynsey Sammons Date photographed: 9/11/25 <br /> Photo numbers Description include violation if applicable <br /> IMG_2159 Emergency Response/Contingency Plan section 3.2 listing local authorities who should <br /> have received a copy of the plan. <br /> IMG 2160 Emergency Response/Contingency Plan template for records of emergency drills <br /> IMG_2161 Uniform Hazardous Waste Manifest 019921869FLE-illegible <br /> IMG_2162 Uniform Hazardous Waste Manifest 019921413FLE- no TSDF signature <br /> IMG_2163 December 20, 2022 monthly inspection checklist for Tanks T-631, T-632, and T-633, <br /> page 1 <br /> IMG-2164 December 20, 2022 monthly inspection checklist for Tanks T-631, T-632, and T-633, <br /> page 2 <br /> IMG-2165 December 20, 2022 monthly inspection checklist for Tanks T-611, T-612, T-616, T-617, <br /> T-618, T-619, page 1 <br /> IMG-2166 December 20, 2022 monthly inspection checklist for Tanks T-611, T-612, T-616, T-617, <br /> T-618, T-619, page 2 <br /> IMG-2167 Weekly visual observations from July 2025, accumulations of oil in secondary <br /> containment not noted <br /> IMG-2168 Weekly visual observation checklist from September 16, 2022-notes of oil observed in <br /> tank farm ground but no follow up action documented <br /> IMG-2169 August 27, 2025 annual inspection checklist for tanks T-100, T-116 through T-120, T- <br /> 611, the 550-gallon diesel tank, and T-631 through T-633, page 1 -unsigned and no <br /> prior inspection date <br /> IMG_2170 August 27, 2025 annual inspection checklist for tanks T-100, T-116 through T-120, T- <br /> 611, the 550- allon diesel tank, and T-631 through T-633, page 2 <br /> IMG_2171 August 27, 2025 annual inspection checklist for tanks T-100, T-116 through T-120, T- <br /> 611, the 550-gallon diesel tank, and T-631 through T-633, page 4-notes on item #18 <br /> regarding broken liquid level device on diesel tank. Notes on item#20 about tanks 117, <br /> 118, and 199 needing re-insulation, no follow up documented. <br /> IMG_2172 Facility Response Plan section 1.3.4. Emergency Response Personnel lists Tim Cowger <br /> and Bryan Yeh, last updated June 16, 2025. Required response training type lists "TBD" <br /> for both personnel. <br /> IMG-2178 Facility Response Plan, page 17-Section 1.4.1.4, Railcar Loading/Unloading <br /> referencing the secondary containments stem for the railcar unloading/loading area <br /> IMG-2179 Master Service Agreement between Patriot Environmental Services and Community <br /> Fuels, dated September 8, 2017. Agreement is referenced in the Facility Response Plan. <br /> IMG-2180 Page 30 of the Facility Response Plan-section response training and practice drills not <br /> implemented. <br /> IMG-2181 Page 33 of the Facility Response Plan-Section 1.8.2, Facility Drills/Exercises <br /> references required Spill Response Drills, not implemented. <br /> IMG_2182 Oily liquid observed inside an open 5-gallon plastic bucket placed under the outlet of a <br /> pipe on the west side of the exterior warehouse wall <br /> IMG_2183 5-gallon plastic bucket observed placed under the outlet of a pipe on the west side of the <br /> exterior warehouse wall <br /> IMG_2184 55-gallon poly drum observed uncapped at the end of a pipe outlet from a tank in the <br /> distillation area <br /> Page 1 of 2 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T(209)468-3420 1 https://www.s'gov.org/department/envhealth/home <br />