EHD Program Facility Records by Street Name
>
T
>
TOKAY
>
32
>
2300 - Underground Storage Tank Program
>
PR0528780
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2026 2:50:00 PM
Creation date
2/9/2026 2:47:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0528780
PE
1862 - CalARP PROGRAM 2 FACILITY
FACILITY_ID
FA0003901
FACILITY_NAME
PACIFIC COAST PRODUCERS (TOKAY)
STREET_NUMBER
32
Direction
E
STREET_NAME
TOKAY
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04703020
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
32 E TOKAY ST LODI 95240
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pacific Coast Producers - Lod Ammonia Refrigeration <br />Anhydrous Ammonia Refrigeration System 1/5/2022 <br />No. F C R Consequence Safeguards and Control Measures Suggested Safeguards and <br />Control Measures <br />Management Response / Action Taken Estimated <br />Completion <br />Date <br />Assigned To Actual <br />Completion <br />Date <br />4.21 2 2 C Loss of oil cooling <br />associated with the <br />compressors. <br />SC-4 has LIC for oil cooling as a backup. <br />Ammonia detection system inside engine room. <br />SC-4 high temperature cutout. <br />Consider evaluating flow switch <br />to indicate loss of water for oil <br />cooling. <br />Consider evaluating <br />reciprocating compressor high <br />discharge and oil temperature <br />cutout functions. <br />Have a quote and have issued a PO for this. <br />Part to be received by October 15, 2024. <br />Installation by January 1, 2025 <br />Information from SMI log indicates all site flow <br />indicators were replaced and an additional 2 <br />installed October 7, 2022. <br />10/15/2024 <br />Install 1/1/25 <br />SMI Flow switch <br />completed <br />12/20/2024 <br />6.01 2 2 C Ammonia release at <br />system pressure, if <br />vessels are not <br />isolated. <br />Procedures for oil draining have been <br />developed by refrigeration contractor. <br />Deadman valves are installed at oil draining <br />locations or a portable deadman valve is used. <br />Oil draining is an attended procedure. <br />Consider acquiring a portable <br />eyewash/shower station, <br />drench hose or an additional <br />fixed installation unit. <br />A portable eyewash station is installed in the <br />compressor room. <br />Jul-22 T. Tran Jul-22 <br />6.03 2 2 C Compromise Personnel <br />safety <br />Two exits from cold rooms. Egress issues not <br />expected. Oil draining conducted prior to <br />season before bins are in the room. <br />Consider the need for a buddy <br />or attendant in addition to the <br />technician for performing oil <br />draining. <br />SOP #111 states this is a one person job. SOP <br />#111 has been updated to state this is a two <br />person job. <br />10/31/2024 SMI 10/8/2024 <br />7.02 2 3 B If diffusion tank <br />pressure rating is <br />exceeded and fails, <br />potential for ammonia <br />vapor release at system <br />head pressure. If tank <br />doesn't fail and system <br />pressure builds, <br />another component in <br />the system may fail if <br />component pressure <br />ratings are exceeded. <br />PRVs set pressure are equal to or less than <br />vessel MAWP. <br />Manual emergency blowdown switch. <br />Emergency fire control box with equalization <br />valve. <br />See Node for recommendation <br />4.15. <br />Pressure relief valve calculations provided and <br />show that the valve design is adequate. <br />10/10/2024 SMI 10/10/2024 <br />7.04 2 4 B Personnel safety, <br />Inadequate notification <br />to facilitate immediate <br />emergency response. <br />PM program includes testing ammonia <br />equipment alarms. Semi annual calibration of <br />ammonia detectors and alarms. Email and text <br />call out for engine room ammonia detectors. <br />Consider upgrading the <br />ammonia detection systems to <br />add in audio/visual alarms <br />outside cold storage rooms, <br />notification on PLC and alarms <br />of a PRV release at the <br />diffusion tank. <br />On 2/15/2024 SMI completed horns/strobes for <br />cold rooms. These are inside the room. There <br />is audio notification. <br />By 10/15/24 SMI will upgrade ammonia <br />detection to add notification on PLC of diffusion <br />tank. <br />1/1/2025 SMI 2/15/24 <br />Horns/strobes <br />PLC for <br />diffusion tank <br />completed <br />10/25/2024 <br />8.02 2 3 B Personnel safety Ventilation fan installed in engine room. Consider upgrading the <br />ventilation fan to and updraft <br />fan that meets the ammonia <br />detection activation setpoints <br />and continuous and emergency <br />ventilation flow requirements of <br />IIAR 2. <br />Fan in place meets requirements at the time of <br />installation. Fan has already been converted to <br />an "ON-AUTO" switch. <br />SMI is replacing the fan and motor with <br />nonsparking components. Parts have a 14- <br />week lead time, so this task will be completed <br />by March 2025 <br />Mar-25 SMI Mar-25 <br />8.05 1 1 D Potential damage to <br />ammonia system. <br />Facility is located within 500 year flood zone <br />with an anticipated depth of less than one foot. <br />Consider developing or <br />updating the Flood Emergency <br />Response Plan to include <br />shutdown and/or protection of <br />the ammonia refrigeration <br />system. <br />The ammonia system is only in operation from <br />June - September each year. There is no <br />possibility that a flood event will occur during <br />the time the system is in operation; therefore, <br />the system is in shutdown mode when <br />possibility for flood event to occur. The <br />recommendation is not necessary to protect the <br />health and safety of the employer's own <br />employees, or the employees of contractors. <br />Declined <br />8.10 1 3 C Potential damage to <br />ammonia system. <br />Design basis of system met seismic restraint <br />requirements at time of construction. Added <br />seismic restraints to piping. Seismic <br />assessment conducted and repairs verified by <br />engineer. <br />Design basis complies with local building code <br />requirements. <br />Consider reaching out to CUPA <br />on when the next seismic <br />assessment revalidation is due. <br />The last seismic assessment <br />follow up was completed in <br />2019 after the 2016 seismic <br />assessment. <br />Seismic assessment completed in 2022, <br />recommendations completed and engineer re- <br />evaluation completed 9/18/2024. Engineer <br />recommended additional repair of exposed <br />rebar. Photos to engineer on 9/26/24; we will <br />receive the report after photos are provided. <br />Received confirmation report from engineer on <br />10/10/2024 that recommendations were <br />completed. <br />9/18/2024 <br />Report received <br />10/10/2024 <br />8.16 2 3 B Personnel safety and <br />inability to isolate <br />equipment/valves <br />resulting in an <br />increased release <br />potential <br />Emergency stop switch is located outside the <br />engine room. King valves and fire emergency <br />control box are accessible at ground level. <br />See Node 3.12 for <br />recommendation. <br />Valves have been labeled. 0 SMI July 2022 and <br />October 8, <br />2024 <br />8.18 2 4 B Personnel safety There are no adjoining walls to production <br />areas and the engine room. <br />See Node 7.04 for <br />recommendation. <br />SMI 2/15/24 <br />Horns/strobes <br />8.19 3 3 B Personnel safety. <br />Ventilation in machine <br />room runs continuously <br />designed to purge <br />machine room. <br />Ammonia detection inside engine room alarms <br />at 25 ppm and has email and text call outs. <br />See Node 4.10 for <br />recommendation. <br />1/1/2025 <br />(replace fan <br />and motor) <br />0 9/23/24-Fan <br />switch replaced <br />Updraft fan with <br />nonsparking <br />blades <br />9.01 2 2 C Corrosion of external <br />surfaces causing a <br />leak. <br />Regular inspection of piping and vessels for <br />corrosion and damaged or failed insulation. <br />Ammonia detecting inside engine room alarms <br />at 25 ppm. <br />Consider repairing piping <br />insulation breaches following <br />the installation of seismic <br />bracing inside engine rooms. <br />Piping insulation breaches repaired (see photos <br />"LCS Insulation", "LCS Sealed Pipes 1" and <br />"LCS Sealed Pipes 2" <br />1/1/2025 SMI 10/8/2024 <br />9.05 2 3 B Personnel safety. <br />Equipment damage if <br />undersized and <br />increased release <br />potential from damaged <br />equipment. <br />PRVs are replaced every 5 years. See Node 4.15 for <br />recommendation. <br />Pressure relief valve calculations provided and <br />show that the valve design is adequate. <br />10/10/2024 SMI 10/10/2024 <br />9.06 2 4 B Personnel safety. <br />Equipment damage if <br />undersized and <br />increased release <br />potential from damaged <br />equipment. <br />PRVs are replaced every 5 years. See Node 7.04 for <br />recommendation. <br />On 2/15/2024 SMI completed horns/strobes for <br />cold rooms. These are inside the room. There <br />is audio notification. <br />By 10/15/24 SMI will upgrade ammonia <br />detection to add notification on PLC of diffusion <br />tank. <br />1/1/2025 SMI 2/15/24 <br />Horns/strobes <br />PLC for <br />diffusion tank <br />completed <br />10/25/2024 <br />9.16 2 2 C Personnel safety. Eyewash/showers are located inside and <br />outside the engine room. <br />Regular inspection and maintenance of <br />emergency response equipment. <br />See Node 6.01 for <br />recommendation. <br />A portable eyewash station is installed in the <br />compressor room. <br />7/1/2022 T. Tran 7/1/2022 <br />Table 1 (Recommendations), Page 2
The URL can be used to link to this page
Your browser does not support the video tag.