My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2026
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
601
>
2300 - Underground Storage Tank Program
>
PR0231348
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/1/2026 1:46:22 PM
Creation date
2/11/2026 2:23:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0231348
PE
2361 - UST FACILITY
FACILITY_ID
FA0003803
FACILITY_NAME
KETTLEMAN CHEVRON
STREET_NUMBER
601
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04728006
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\bmascaro
Supplemental fields
Site Address
601 E KETTLEMAN LN LODI 95240
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN aOAQUIN AMENDED Environmental Health Department <br /> —COUNTY— 1�22�2026 <br /> „realness grows here. <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> KETTLEMAN CHEVRON 1601 E KETTLEMAN LN LODI Jul 24 2025 <br /> 11 2637(a-d), 2712(b)(1)(F) 2030048-Sec containment testing conducted per requirements & records kept for 36 mths <br /> (TCR 9d) <br /> OBSERVATION: Secondary containment testing was completed on 1/29/2024 and 6/11/2024, the test results were not <br /> found on site at the time of inspection. <br /> REGULATION GUIDANCE: A copy of the test report must be kept on site for 36 months from the date that the testing <br /> was performed. <br /> CORRECTIVE ACTION: Immediately locate the test results and ensure it is kept on site for 36 months from the date that <br /> the testing was performed. Provide a corrective action statement to EHD. <br /> This is a Repeat (Minor)Violation. <br /> 14 2637.2(d&e), 2665(a&b) 2010018 - Overfill prevention equipment inspection report form submitted to the UPA within 30 <br /> days <br /> OBSERVATION: A repair overfill prevention equipment inspection was performed on 6/11/2024 and a test report was <br /> submitted on 8/7/2024, 27 days late. <br /> REGULATION GUIDANCE: A copy of the test report must be submitted within 30 days of the tests. <br /> CORRECTIVE ACTION: Take all necessary precautions to ensure testing and submittal of test reports are performed in <br /> a timely manner. <br /> This is a (Minor)Violation. <br /> 25 2631(g), 2632(c)(2) 2030016 -Annular space of USTs are continuously monitored with an audible and visual alarm <br /> system (TCR 9d) <br /> OBSERVATION: the 407 annular sensor for the 91 tank was in alarm after being tested and failed to turn off. <br /> REGULATION GUIDANCE: The interstitial space shall be monitored with a monitoring system connected to an audible <br /> and visual alarm system. <br /> CORRECTIVE ACTION: Service Technician Steve Miller replaced the 407 sensor with a 409 sensor at the time of <br /> inspection. No further action needed. <br /> This was corrected on site. <br /> This is a (Minor)Violation. <br /> 30 2630(d), 2641(a) 2060015- Leak detection equipment located so leak is detected at the earliest possible opportunity <br /> (TCR 9d) <br /> OBSERVATION: The 208 sensor located in the 87 STP sump was raised approximately 6 inches off the lowest point of <br /> the sump and not located to detect a leak at the earliest opportunity. <br /> REGULATION GUIDANCE: Monitoring equipment shall be maintained to be able to detect a leak at the earliest possible <br /> opportunity. <br /> CORRECTIVE ACTION: The sensor was relocated to the lowest point of the sump by the service technician Steve Miller. <br /> Ensure that all monitoring equipment is maintained and located to detect a leak at the earliest opportunity. No further <br /> action needed. <br /> This was corrected on site. <br /> This is a Repeat (Class 2)Violation. <br /> EHD-CUPA Inspection Report IS03 Page 5 of 8 FA0003803 PR0231348 4528589 1/22/2026 <br /> CP22-U aST FULL g <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.