M
>
MARCH
>
1916
>
2300 - Underground Storage Tank Program
>
PR0527728
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/23/2026 4:58:37 PM
Creation date
2/11/2026 4:14:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0527728
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0018792
FACILITY_NAME
AB MARCH LN OPERATIONS INC
STREET_NUMBER
1916
Direction
E
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09603029
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\bmascaro
Supplemental fields
Site Address
1916 E MARCH LN STOCKTON 95210
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Monitoring System Certification Form <br /> 8. IN-TANK GAUGING TESTING <br /> El Check this box if tank gauging is used only for inventory control. <br /> ❑ Check this box if NO tank gauging equipment is installed. Yes No NA <br /> Do not complete this section if either box is checked. <br /> All wiring has been: 1) visually inspected for kinks, breaks and proper entry and ❑ ❑ ❑ <br /> termination; and 2 tested for ground faults? <br /> Were all in-tank gauging probes visually inspected for damage and residue buildup ❑ ❑ ❑ <br /> to ensure that floats move freely, functionally tested, and confirmed operational? <br /> Was accuracy of system's product level readings tested? ❑ ❑ ❑ <br /> Was accuracy of system's water level readings tested? ❑ ❑ ❑ <br /> Were all probes reinstalled properly? ❑ ❑ ❑ <br /> Were all items on the equipment manufacturer's maintenance checklist completed? ❑ ❑ I ❑ <br /> Probe ID Probe Model Tanks Monitored Pass Fail <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> 9. COMMENTS <br /> Describe all answers marked "No"or "Fail'and proposed remedy. <br /> List all monitoring equipment either replaced or repaired. <br /> HAD A FEW ISSUES TODAY ON SITE , H2O IN SUMPS, UANSWERED ALARMS. <br /> ACTIVE ALARM CONDITIONS: <br /> L - 17 87 OCTANE FILL SUMP, IN LIQUID. <br /> L - 22 91 FILL SUMP & BRINE SENSORS, ALARM WOULDN'T CLEAR , CLEANED SENSOR, TESTED SENSOR <br /> AND PUT BACK IN SERVICE. BRINE RESERVOIR IS EMPTY. HOWEVER THIS IS THE ONLY SENSOR SETUP THAT <br /> USES THE 2 -1 SENSOR BLOCK, BOTH OF THESE SESNORS ARE WORKING FAULTY THESE ARE BOTH A FAIL <br /> AND NEED REPAIR/ RETEST. <br /> L - 24 DIESEL S T P SUMP BRINE , SENSOR TESTED GREAT. RESERVOIR IS EMPTY. <br /> L - 26 DIESEL FILL SUMP BRINE , SENSOR TESTED GREAT . RESERVOIR IS EMPTY. <br /> ALL THREE FILL SUMPS ARE ALSO FULL OF H20 , AT CONCLUSION OF TESTING WE REMOVED ALL LIQUID <br /> AND PLACED IN ON SITE CONTAINMENT. <br /> WE FOUND TWO BAD SENSORS DURING TESTING AS WELL, <br /> L - 12 DISPENSER 11/12 BRINE SENSOR DOES NOT FUNCTION, RESERVOIR HOLDS LIQUID. <br /> L - 22 91 FILL SUMP -2 0 8 DOES NOT ALARM. - BRINE ALARM AT ARRIVAL. <br /> IN THE TANK FIELD , ALL SUMP RESERVOIRS ARE LOW OR EMPTY. <br /> Page 5 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.