Laserfiche WebLink
TABLE 1 <br /> WELL COMPLETION DETAILS <br /> Jamar Service Station, 4075 East Main Street, Stockton, CA <br /> Page 2 of 2 <br /> Well Top of Base of <br /> Total Well Casing Screen Screen Length of <br /> General Installation Installation Depth Size Well Casing Interval Interval Screen <br /> Well # Location Well Type Date Oversight By: (feet bgs) (Inches) Material Screen / Completion Type (feet bgs) (feet bgs) (feet) <br /> VEW1 On Site VEW 5/28/2018 ATC 50.6 2 Sch 40 PVC 0.010" Factory Slotted 35 50 15 <br /> VEW2 On Site VEW 5/28/2008 ATC 50.7 2 Sch 40 PVC 0.010" Factory Slotted 35 50 15 <br /> VEW3 On Site VEW 5/28/2008 ATC 51 2 Sch 40 PVC 0.010" Factory Slotted 35 50 15 <br /> *Note: depth of Wells and Screens MW2, MW5, MW6b, MW7b and EW1 appear to be off depth based on later well depth soundings <br /> 1 Based on sounded total depth on 8/13/04 and 9/13/04; See field notes. <br /> 2 Based on sounded total depth on 9/13/04; See field notes. <br /> 3 Based on sounded total depth on 9/13/04; See field notes. <br /> 4 Based on sounded total depth on 9/13/04; See field notes. <br /> 5 Based on sounded total depth on 9/13/04; See field notes. <br /> INJ = Remediation Well <br /> GWM = Ground Water Monitoring <br /> VEW = Vapor Extraction Well <br />