Laserfiche WebLink
Environmental Health Department <br />Telephone: (209) 477-6037 Owner/Operator: PACIFIC COMMONS APT NE POOL <br />Inspection Type: Routine <br />Address: 504 NORTHBANK CT, STOCKTON 95207 <br />Date: 06/04/2025Name of Facility:RIVER ROCK APARTMENTS <br />Reinspection on or after: <br />Swimming Pool Official Inspection Report <br />Program Element: 3612 - PUBLIC POOL/SPA - ADDITIONAL <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public <br />health and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />VIOLATIONS AND CORRECTIVE ACTIONS <br /> #37 Electrical Hazards <br />OBSERVATIONS: The light inside the pool does not turn off when the ground fault circuit interrupter (GFI) is tested. Repair GFI <br />so that it is in good working order today. Close pool area until the corrections are made and verified by this department. <br />CALCODE DESCRIPTION: Electrical equipment installed in the water, walls, deck, or equipment room of a public pool shall comply <br />with California Electrical Code. (CEC 680.4) Light fixtures installed in the pool that operate at more than 15 volts shall be protected by a <br />ground fault circuit interrupter. (CBC 3160B) <br />This is (Major) Violation. <br />MAJOR <br /> #4 Safety Equipment <br />OBSERVATIONS: The body hook pole is broken in half. Replace body hook. Body hook shall be a 12 foot fixed length pole <br />with permanently attached hook. Correct today. <br />CALCODE DESCRIPTION: Safety equipment shall be provided, maintained, readily visible, and available for use. Pools shall have at <br />minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br />rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br />(CCR 65540) <br />This is (Minor - Food) Violation. <br /> #22 Skimmer Assembly <br />OBSERVATIONS: Both skimmers lacked weirs and one skimmer basket was broken with a hole. Install weirs and a new <br />basket in the skimmers. Correct within one week. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall <br />be maintained in accordance with manufacturer specifications. (CBC 3136B) <br />This is (Minor - Food) Violation. <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F <br />Combined chlorine:ppm7.8 <br />5.6 <br />0 <br />70 <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br /> PR0360522 06/04/2025 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD