Laserfiche WebLink
Environmental Health Department <br />Facility Name and Address: FAIRWAY ESTATES APARTMENTS, 1155 W CENTER ST, MANTECA 95336 <br />Swimming Pool Official Inspection Report <br /> #9 Ladders and Handrails <br />OBSERVATIONS: Single hand rail is not secured. Secure hand rail in 1 week. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a <br />point above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) <br />Pool operator shall keep ladders and handrails well maintained. (CCR 65535) <br />This is (Minor - Food) Violation. <br /> #15 Operation Records <br />OBSERVATIONS: Pool logs are on site but not maintained on daily basis. Maintain logs today and regularly after. REPEATED <br />VIOLATION. <br />CALCODE DESCRIPTION: Pool operator shall test the disinfectant residual, pH, and spa water temperature a minimum of once per <br />day. Cyanuric acid concentration shall be tested once per month if cyanuric acid is used. Combined chlorine shall be tested as often <br />as necessary to maintain the concentration below 0.4 ppm. Pool operator shall maintain written records of all maintenance and test <br />results for at least two years and shall submit those records to the enforcement agency upon request. (CCR 65523) <br />This is (Minor - Food) Violation. <br /> #19 Depth Markers <br />OBSERVATIONS: Pool deck is lacking Depth markers with Universal NO DIVING symbols. Provide depth markers along the <br />pool perimeter. Depth markers shall be 4 inches high in a contrasting color and be marked in units of feet and inches. For pool <br />water depths 6 feet and shallower, markers with universal "NO DIVING" symbol shall be installed on the deck directly adjacent <br />to the depth markers. Correct in 4 weeks. REPEATED VIOLATION. <br />CALCODE DESCRIPTION: Depth markers shall be clearly marked in the following locations: at maximum depth, at minimum depth, at <br />each end, on both sides at each end, at the slope break, and along the perimeter of the pool at distances not to exceed 25 feet. Depth <br />markers shall be 4 inches high in a contrasting color and be marked in units of feet and inches. For pool water depths 6 feet and <br />shallower, markers with universal "NO DIVING" symbol shall be installed on the deck directly adjacent to the depth markers. (CBC <br />3110B) <br />This is (Minor - Food) Violation. <br /> #22 Skimmer Assembly <br />OBSERVATIONS: One skimmer is lacking weir gate. Provide weir gate in 1 week. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall <br />be maintained in accordance with manufacturer specifications. (CBC 3136B) <br />This is (Minor - Food) Violation. <br />Page 2 of 3EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br /> PR0360356 06/16/2025 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD