Laserfiche WebLink
Table 2: Material Storage and Boom-Type or Hoisting Equipment Clearances Required <br /> Overheadfrom Energized <br /> Nominal Voltage (Phase to Phase) Minimum Required Clearance (Feet) <br /> 600 50,000 10 <br /> over 50,000 75,000 11 <br /> over 75,000 125,000 13 <br /> over 125,000 175,000 15 <br /> over 175,000 250,000 17 <br /> over 250,000 370,000 21 <br /> over 370,000 550,000 27 <br /> over 550,000 1,000,000 42 <br /> 8.13.2 Subsurface Work <br /> Subsurface work activities will require adherence to Roux's Corporate Subsurface Utility Clearance <br /> Management program found within Appendix H. <br /> 8.14 Traffic Control <br /> Per Cal/OSHA T8 CCR Section 1598, if Site operations encroach upon public streets or highways and a <br /> hazard exists to Site personnel because of traffic conditions, a traffic control plan will be implemented in <br /> accordance with the California Department of Transportation's(DOT's) "California Manual on Uniform Traffic <br /> Control Devices for Streets and Highways" dated January 13, 2012. <br /> 8.15 Sanitation <br /> Sanitation facilities will be provided in accordance with the sanitation standards(Cal/OSHA T8 CCR Sections <br /> 3364-3366, 29 CFR 1910.141, 29 CFR 1926.51 and 29 CFR 1928.110). Per the Cal/OSHA T8 CCR Section <br /> 3364, separate toilet facilities will be provided for each sex, and hand washing facilities will be accessible <br /> throughout the Site. Sanitation facilities will be maintained and kept in good conditions at all times. <br /> 3989.0001 S.104/HSP Site-Specific Health and Safety Plan I ROUX 136 <br />