Site Boundary Soil Gas Assessment <br /> Concurrent with the sub-slab soil gas and indoor air sampling, four soil gas samples will be <br /> collected from five-foot deep soil gas probes along the southern boundary of the Site immediately <br /> south and southwest of the Quality Cleaners. This work will be performed to assess the potential <br /> for the lateral migration of soil gas and to assess the potential for vapor intrusion into the residential <br /> structures along the southern boundary of the Site. <br /> Sewer Lateral Soil Gas Assessment <br /> Prior to the initiation of field activities, a geophysical survey will be performed to locate the sewer <br /> line on the Site. The geophysical survey will also check the proposed probe locations to ensure <br /> there are no underground utilities in proximity to the probes. Six soil gas samples will be collected <br /> from probes installed along the alignment of the sewer lateral connected to the Quality Cleaners. <br /> The depth of the probes will be at the depth of the sewer lateral as measured from sewer line <br /> cleanouts. The probes will be located in close proximity(i.e., approximately two feet)to the sewer <br /> laterals. This work will be performed to assess whether PCE may have been released from the <br /> sewer lateral. <br /> Groundwater Assessment Related to the Quality Cleaners <br /> At the completion of the soil gas sampling, five groundwater monitoring wells will be installed, <br /> developed, surveyed, and sampled to assess the potential impact to groundwater that may have <br /> resulted from the release of PCE from the Quality Cleaners. Groundwater samples will also be <br /> analyzed for the petroleum hydrocarbon dry cleaning solvent. These wells will be installed in <br /> locations to the south-southwest (upgradient) and north-northeast (downgradient) relative to the <br /> Quality Cleaners. These wells will be monitored to confirm the site-specific groundwater flow <br /> directions. <br /> Initially, three groundwater monitoring wells will be installed in a triangular array so that an <br /> expedited wellhead survey of the three monitoring wells can be performed. The results of the <br /> survey will be used to assess the flow direction of groundwater at the time the wells are installed. <br /> Based on the survey,the remaining two monitoring wells will be installed as proposed.If,however, <br /> the groundwater flow direction is other than to the north-northeast, the DTSC will be contacted so <br /> that alternative locations of the remaining two monitoring wells to be installed can be discussed. <br /> The vertical characterization of the PCE plume will occur in a separate mobilization following the <br /> confirmation of the groundwater flow direction and will consist of continuously cored direct push <br /> soil borings and the collection of grab groundwater samples from targeted strata. As currently <br /> envisioned, up to five pairs of 35-foot deep direct push Geoprobe borings would be advanced at <br /> Sampling and Analysis Workplan <br /> Tracy Corners Shopping Center <br /> 3225 North Tracy Boulevard <br /> Tracy,California 95376 <br /> Partner Project Number SM14-129814 <br /> Docket Number HAS-VCA 14/15-108 <br /> August 15,2016 <br /> Page 19 <br />