ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0541231
PE
2959 - DTSC LEAD AGENCY SITE
FACILITY_ID
FA0023619
FACILITY_NAME
FORMER QUALITY CLEANERS TRACY CORNERS SHOPPING CENTER
STREET_NUMBER
3081
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21418041
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
3081 N TRACY BLVD TRACY 95376
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
549
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The alignment of the approximately 660-foot long sanitary sewer lateral will be identified by a <br /> private utility locator as noted in Section 6.1. The six proposed 5-foot deep soil gas probe locations <br /> along the sewer lateral alignment are shown on Figure 8. The depth of the sewer lateral within the <br /> Site will be assessed by measuring the depth using the sewer cleanout vaults using a tape measure <br /> prior to implementing the field work. <br /> The 5-foot deep soil gas samples proposed for two locations associated with the petroleum <br /> hydrocarbon release are shown on Figure 9. <br /> The proposed three cumulative soil gas assessments will be conducted in general accordance with <br /> the July 2015 DTSC Advisory and will consist of soil gas samples from probes installed with a <br /> direct push Geoprobe. The soil gas samples will be analyzed for VOCs in accordance with EPA <br /> Method 8260 by an on-site mobile laboratory. <br /> The soil gas probes will be permanently installed and secured with a well box for future sampling <br /> events. Probe destruction methods will be provided in an additional work plan upon completion <br /> of onsite activities. <br /> 6.4.1 Proposed Shallow Soil Gas Sample Probe Installation Methods <br /> The soil gas probes will be installed with dual-tube direct push equipment using a Geoprobe. This <br /> technique will allow a soil gas probe to be purged and sampled approximately two hours following <br /> the final installation of the probe. <br /> The soil gas probes will be secured and completed to prevent infiltration of water or ambient air <br /> into the subsurface and to prevent accidental damage or vandalism. The tubing will be marked at <br /> the surface to identify the probe location and depth. A gas-tight valve or fitting for capping will be <br /> affixed to the sampling tube. <br /> To allow for the subsurface to equilibrate to representative conditions, each probe will not be <br /> purged or sampled for at least two hours following probe installation. <br /> The soil gas probes will be permanently installed and secured with a well box for future sampling <br /> events. Probe destruction methods will be provided in an additional work plan upon completion <br /> of onsite activities. <br /> Sampling and Analysis Workplan <br /> Tracy Corners Shopping Center <br /> 3225 North Tracy Boulevard <br /> Tracy,California 95376 <br /> Partner Project Number SM14-129814 <br /> Docket Number HAS-VCA 14/15-108 <br /> August 15,2016 <br /> Page 24 <br />