My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
600
>
2900 - Site Mitigation Program
>
PR0548753
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/2/2026 11:33:41 AM
Creation date
3/2/2026 11:15:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0548753
PE
2959 - DTSC LEAD AGENCY SITE
FACILITY_ID
FA0027916
FACILITY_NAME
BOBSON CLEANERS, INC.
STREET_NUMBER
600
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
22314117
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
600 N MAIN ST MANTECA 95336
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
558
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Cleanup in Vulnerable Communities'Initiative Final Project Reference:Bobson Cleaners <br /> Discovery and Enforcement Discovery Project Number:60688620-5.1 <br /> Investigation Work Plan <br /> 4. Quality Assurance Project Plan <br /> This section describes the QAPP,which provides an appropriate level of QA and QC regarding the reliability and <br /> usability of the data generated during the DI.An integral part of the QAPP is proper field sampling and documentation <br /> procedures,which have already been described in Section 3 above and,thus,will not be repeated herein.This <br /> section sets forth the policies, procedures, and activities for the identification and documentation of the quality of the <br /> data generated during the performance of the DI. <br /> During the DI, a variety of data will be collected. Each sample collected may be analyzed for a number of different <br /> chemicals, depending on the rationale for sample collection. However, not all chemicals detected will necessarily be <br /> attributable to an onsite release, and not all of the data will necessarily be of acceptable quality. Data collected will be <br /> evaluated to determine which of the chemicals identified are likely to be Site-related and to assess whether the <br /> reported concentrations for these chemicals are of acceptable quality for use in the human health screening <br /> evaluation. <br /> 4.1 Data Quality Objective Process <br /> The project DQOs developed specifically for the planned sampling and analysis program have been determined <br /> based on USEPA's seven-step DQO process (USEPA 2000). The Project QA Manager will evaluate the project DQOs <br /> to determine whether the quantitative and qualitative needs of the sampling and analysis program have been met. <br /> The project definition associated with each step of the DQO process can be summarized as follows: <br /> • State the problem: The purpose of the sampling program is to determine whether the proposed Site is <br /> acceptable for an intended use scenario: <br /> The Site was developed in 1968 and operated as a dry cleaner from at least 1968 to 2005,according to city <br /> directories and the EDR reports.A total of 127 manifests for PCE waste was identified on the HWTS database <br /> from 1993 until 2005.A 30-gallon PCE release occurred due to power failure,which was reported to the San <br /> Joaquin County Emergency Services on May 2, 2001.Additionally, the boiler overflowed, and evacuation of the <br /> building was required.The historical dry cleaner operations utilizing PCE with a reported spill is considered a <br /> REC, and the release of chlorinated solvents may pose a risk to human health and the environment. Currently, <br /> the Site is operating as a commercial space and has been occupied by an insurance office and a massage <br /> parlor since 2010.The Site case is listed as open with vapor intrusion verification monitoring needed. Discovery <br /> sampling is necessary to determine if the former dry-cleaning facility released chlorinated solvents to the <br /> environment. <br /> • Identify the Decision:The data obtained from the sampling and testing activities will be used to evaluate <br /> whether releases of hazardous substances from historical uses have occurred at the Site.The data obtained will <br /> be further evaluated to determine to what extent any found contamination or naturally occurring constituent <br /> concentration will result in risk of exposure.The data results will be compiled and used to assess the relative <br /> threat associated with onsite constituent concentrations through screening risk evaluations performed in <br /> accordance with the procedures set forth in the Programmatic QAPP. Based on the screening risk calculations <br /> for the Site,the suitability of the property for its intended development will be determined. <br /> • Identify Inputs to the Decision: The investigation report will contain general descriptions of inputs to the <br /> decision. Inputs to the decision will include results of analytical testing of soil gas samples and/or groundwater <br /> samples from selected locations on the Site. Each matrix that is tested will be tested for the specified analytes <br /> discussed in Section 3, and the results will be presented in investigation report.An example table and figure are <br /> included as Table 4 and Figures 6A and 6B in this work plan. <br /> • Define the Study Boundaries: The boundaries of the field sampling and analysis program will be the perimeter <br /> of the Site as defined by the Phase I Report conducted by AECOM (AECOM 2023)and per site access.The <br /> depth will be limited to 16 feet bgs. Soil gas will not be conducted during inclement weather or for 5 days <br /> following a rain event with greater than 0.5 inches of precipitation during a 24-hour period. Sampling will only <br /> occur Monday through Friday between 7am and 6pm. <br /> • Develop a Decision Rule: Decisions will be based upon laboratory results for the target constituents and <br /> presented in figures and tables similar to the templates in Figure 6 and Table 4,for each respective matrix <br /> Prepared for: Department of Toxic Substances Control AECOM <br /> 23 <br />
The URL can be used to link to this page
Your browser does not support the video tag.