My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
600
>
2900 - Site Mitigation Program
>
PR0548753
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2026 2:32:59 PM
Creation date
3/2/2026 11:15:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0548753
PE
2959 - DTSC LEAD AGENCY SITE
FACILITY_ID
FA0027916
FACILITY_NAME
BOBSON CLEANERS, INC.
STREET_NUMBER
600
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
22314117
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
600 N MAIN ST MANTECA 95336
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
616
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Cleanup in Vulnerable Communities'Initiative Final Project Reference:Bobson Cleaners <br /> Discovery and Enforcement Discovery Project Number:60688620-5.1 <br /> Investigation Work Plan <br /> either waste oil and/or petroleum. It is unknown if both were stored in the UST or if there were two USTs on <br /> site.The USTs were listed as inactive on the EDR report and contained waste oil and petroleum. No other <br /> information is available on the EnviroStor or GeoTracker websites for this facility. Due the unknown historical <br /> information from the case closure of the USTs, regulatory status, and hydrogeological position relative to the <br /> Site(i.e., up-gradient),this facility presents a REC to the Site. <br /> • Manteca Tire(201 West Edison Street)is located approximately 235 feet to the west of the Site and listed on <br /> the EDR as RCRA NonGen/NLR, CERS Haz Waste, CERS, HTWS. This facility is listed as a chemical <br /> storage facility and has had several violations related to its business plan, uploading of documents and <br /> emergency response plans. The facility was also found in violation of nor accurately reporting hazardous <br /> materials stored onsite. A bulk 200-gallon oil AST, bulk 200-gallon waste oil AST, 55-gallons of new antifreeze, <br /> and 55-gallons of waste antifreeze were found onsite and not properly reported in 2015. Due to unknown <br /> historical information regarding the stored chemicals on the facility,this facility presents a REC to the Site. <br /> No controlled RECs(CRECs), historical RECs(HRECs), or de minimis conditions(DMCs)were identified in <br /> connection with the Site during the ESA. <br /> Based on the above-described activities,AECOM recommended conducting a limited Phase II ESA to further assess <br /> the following RECs and items of concern: <br /> • Conduct a site investigation around the former dry cleaner to assess potential chlorinated solvent impacts to <br /> media of concern at the Site. <br /> • Conduct soil vapor sampling onsite to assess potential for vapor encroachment condition (VECs)from off-site <br /> sources, i.e.the historical USTs and automotive repair located to the west,southwest and north of the Site. <br /> • Although not a REC, impacts resulting from the presence older structures built before 1973 the potential for <br /> asbestos containing materials(ACMs), lead-based paint, and pesticides is likely.This is a potential item of <br /> concern and therefore AECOM recommends collecting soil samples throughout the Site and analyze for <br /> asbestos, lead-based paint,and pesticide(termiticide)impacts. <br /> Aside from the 2023 AECOM Phase I ESA, no other reports have been prepared in connection with the Site. <br /> 2.7 Future Water Supply <br /> The Site is located within the Eastern San Joaquin Valley subbasin of the San Joaquin Valley aquifer system and is <br /> covered by the Eastern San Joaquin Groundwater Authority. <br /> 2.8 Observations from Site Reconnaissance <br /> As part of the Phase 1 ESA, a site reconnaissance was conducted by AECOM on August 9th, 2022,with the intent of <br /> contacting the Site owner/manager.The site visit methodology consisted of walking over accessible areas of the Site, <br /> the perimeter, and portions of the surrounding area.At the time of the site visit,the Site was a commercial building <br /> occupied with two commercial businesses. AECOM did not have access to the interior of the structure. AECOM was <br /> able to access the entry way of each business upon arrival and made visual observations and documented what was <br /> seen. No features of the former dry cleaner could be seen inside either business during the site visit. <br /> The Site is developed with a rectangular-shaped single-story building on the eastern portion of the Site and the <br /> remainder of the Site is asphalt-paved parking lot,with the exception of the southwestern corner which is a dirt lot. <br /> The building is occupied by two businesses, Best Foot Massage and His Will Insurance. There is a PG&E pad- <br /> mounted transformer and a natural gas meter near the northwest corner of the of the building. PG&E supplies the <br /> building with natural gas and electricity. Utility poles run east and west along the northern and southern boundaries of <br /> the site. No visual evidence of present aboveground storage tanks(ASTs)or underground storage tanks(UST's), <br /> irrigation or potable water wells, monitoring wells, dry wells, clarifiers, septic systems,discolored soil, standing <br /> surface water, stressed vegetation, or unusual odors was observed on the Site. <br /> Prepared for: Department of Toxic Substances Control AECOM <br /> 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.