Laserfiche WebLink
TABLE 5-SUMMARY OF IDW AND RINSATE SAMPLING AND ANALYTICAL METHODS <br /> CVCI-Discovery Work Plan <br /> Bobson Cleaners Inc. <br /> 600 North Main Street <br /> Manteca,California 95336 <br /> Material Laboratory Analysis Tested for Material Management/Disposal Sample Collection Method <br /> Any excess water will be poured into 55-gallon drums or 3 x 40-mL VOA vials(HCI&4°C(no <br /> Rinsate Samples Blanks EPA Method 8260 VOCs portable s.torage tanks,labeled with the sample location headspace)) <br /> and date,and sealed <br /> Used personal protective equipment(PPE) <br /> (Unless there is contact with apparently contaminated N/A N/A Double bagged and placed in a municipal refuse dumpster. N/A <br /> material) <br /> Disposable sampling equipment N/A N/A Double bagged and placed in a municipal refuse dumpster. N/A <br /> Purged groundwater and excess groundwater EPA Method 8260 VOCs Poured into 55-gallon drums or portable storage tanks, 3 x 40-mL VOA vials(HCI&4°C(no <br /> collected for sample container filling labeled with the sample location and date,and sealed. headspace)) <br /> Decontamination fluids N/A N/A Poured into 55-gallon drums or portable storage tanks and 3 x 40-mL VOA vials(HCI&4°C(no <br /> labeled as"decontamination water'. headspace)) <br /> Placed into 55-gallon drums or bins that will be labeled with If apparently contaminated:sequester <br /> Soil Cuttings EPA Method 8260 VOCs the source material sample locations(the soil borings or soil sample and identify by boring location and <br /> gas probe locations)and sealed. sample interval. <br />