Laserfiche WebLink
TABLE 4 <br /> SUMMARY OF WELL AND PROBE CONSTRUCTION DETAILS <br /> CANCUN RESTAURANT <br /> 135 EAST MINER AVENUE <br /> STOCKTON, CALIFORNIA <br /> Well/Probe Installation Well/Probe Bottom of Top of Screen <br /> Designation Date Diameter Boring Sand Pack Interval <br /> (inches) (ft-b s) (ft-b s) (ft-b s) <br /> Groundwater Monitoring Wells <br /> MW-lA 08/06/2010 2 40 18 20-40 <br /> MW-113 08/05/2010 2 60 53 55-60 <br /> MW-2A (proposed) 2 35 18 15-35 <br /> MW-213 07/30/2010 2 60 53 55-60 <br /> MW-3A (proposed) 2 35 18 15-35 <br /> MW-313 07/29/2010 2 60 53 55-60 <br /> MW-413 08/05/2010 2 60 53 55-60 <br /> MW-5A (proposed) 2 35 18 15-35 <br /> MW-513 (proposed) 2 60 53 55-60 <br /> Remediation Wells <br /> VW-1 05/20/2021 2 10.5 5 5.5-10.5 <br /> Vapor Probes <br /> SV-1 09/05/2017 0.25 6.5 5 5.75-6 <br /> SV-2 09/05/2017 0.25 6.5 5 5.75-6 <br /> SV-3 (proposed) 0.25 6.5 5 5.75-6 <br /> SV-4 (proposed) 0.25 6.5 5 5.75-6 <br /> Sub-Slab Vapor Probes <br /> SS-1 (proposed) 0.25 0.42* N/A - vapor pin N/A - vapor pin <br /> SS-2 (proposed) 0.25 0.42* N/A - vapor pin N/A - vapor pin <br /> Notes: <br /> [1] Depths measured in feet below ground surface. <br /> * Assumes 1"below bottom of a 4"concrete slab. <br /> FREY Environmental, Inc. Table 4 Project No. 1092-01 <br />