My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2026
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DA VINCI
>
4627
>
2300 - Underground Storage Tank Program
>
PR0231074
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/3/2026 12:08:47 PM
Creation date
3/5/2026 3:50:46 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0231074
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0002541
FACILITY_NAME
7-ELEVEN INC #20632
STREET_NUMBER
4627
STREET_NAME
DA VINCI
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
11002003
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
4627 DA VINCI DR STOCKTON 95207
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Monitoring System Certification Form <br /> 8. IN-TANK GAUGING TESTING <br /> Z Check this box if tank gauging is used only for inventory control. <br /> l] Check this box if No tank gauging equipment is installed. Yes No NA <br /> Do not complete this section if either box is checked. <br /> All wiring has been: 1) visually inspected for kinks, breaks and proper entry and 11 0 11 <br /> termination; and 2) tested fof ground faults? <br /> Were all in-tank gauging prates visually inspected for damage and residue buildup ll Lj li <br /> to ensure that floats move freely, functionally tested, and confirmed a erationaI? <br /> Was accuracy of system's product level readings tested? J J J <br /> Was accuracy of system's water level readings tested? .11 El El <br /> Were all probes reinstalled properly? ll Ll ll <br /> Were all items on the equipment manufacturer's maintenance checklist completed? <br /> Probe ID Probe Model Tanks Monitored Pass Fail <br /> Ll Ll <br /> J J <br /> j It <br /> El Ll <br /> El Li <br /> 9. COMMENTS <br /> Describe all answers marked "No" or '`Fail" and proposed remedy. <br /> List all monitoring equipment either replaced or repaired. <br /> Page 5 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.