Laserfiche WebLink
Nitrate Loading Calculations: <br /> Variable Value Units Description <br /> Q 500 gallons per day Effluentflow rate from report <br /> Nw 35 mg/L-N Effluent stream concentration from report <br /> A 2.0 acres Site area from report <br /> Nb 0.103 mg/L-N Concentration of rain water from report <br /> d 0.35 constant Denitrification factor from report <br /> R 3.68 inches per year Recharge rate of rainfall from report(evapotranspiration method) <br /> W 3.4 inches per year Uniform waste water loading for site calculation result <br /> Nc 10.9 mg/L-N RESULT: Long-term average concentration of percolating effluent <br /> Find Variable(W: <br /> (W) in = (Q) gal x 1 ft3 x 365365 day(s) x 1 acre x 12 in x 1 site <br /> yr day 7.48 gal 1 year 43,560 ft2 1 ft (A)acre(s) <br /> 3.36 in/yr(site)=500 gal/day x(1 cu-ft/7.48 gals)x(365 days/1 year)x(1 acre/43,560 sq-ft)x(12 in/I ft)x(1 site/2 acres) <br /> Hantzsche-Fennemore Equation X& <br /> Nc= WN (1-d)+RNh <br /> W+R <br /> 10.91 mg/L-N=((3.36 in/yr x 35 mg/L-N x(1-0.35))+(3.68 in/yr x 0.103mg/L-N))/(3.36 in/yr+3.68 in/yr) <br /> Assumptions: <br /> 1. Total nitrogen concentration of influent waste stream is 35 mg/L-N. If different influent concentrations exist,use weighted average <br /> 2. Fraction of nitrate-N loss due to denitrification in the soil is 35%. <br /> 3. Estimated deep percolation of rainfall is 3.68 in/yr. <br /> 4. Background nitrate-N concentration of rainfall is 0.103 mg/L-N. <br /> Nitrate Loading Calculation Plate No.: 16 <br /> Brouwer Property Project No: 2606 <br /> LIVE OAK 350 E.Critchett Ave. Date: February 23,2026 <br /> GEO ENVIRONMENTAL INC. Tracy,CA <br />